INSTALLATION AND OPERATION INSTRUCTIONS
4400QC SERIES POWER PAKS
IMPORTANT INFORMATION
To register your product, visit our web site at
perlick.com Commercial Service. Click on , then .
You will see the link to Warranty Registration Form.
You must complete and submit this form or the
installation date will revert back to the ship date.
Permanently mount the enclosed Warning/Safety
Instruction label in a visible location near the CO2
regulator.
This manual has been prepared to assist you in the
installation of your 4400QC Series Power Pak and to
acquaint you with its operation and maintenance.
We dedicate considerable time to ensure that our
products provide the highest level of customer
satisfaction. If service is required, your dealer can
provide you with a list of qualified service agents.
For your own protection, never return merchandise
for credit without our approval.
We thank you for selecting a Quick Chill product and
assure you of our continuing interest in your
satisfaction.
8300 West Good Hope Road • Milwaukee, WI 53223Phone 414.353.7060 • Fax 414.353.7069
Toll Free 800.558.5592E-Mail perlick@perlick.com • www.perlick.com
Table of Contents
Sizes & Specications ............................................2-3
General Information 3 ..........................................
Installation 3-4 .....................................................
Connecting Power Pak to Trunk Housing 4-5 ...........
Power Pak Start-Up 5-6 ................................................
LEDS 6-7 ......................................................................
Preventative Maintenance 6-7 ......................................
Replacement Parts 7 ....................................................
Wiring Diagrams 8 ........................................................
Form No. Z0507QC
Rev. 06.01.23
C
US
MODELS
Compressor Size 1/3 HP 1/2 HP 3/4 HP 1-1/2 HP
# of
Circulating
Pumps
1 4404QC 4410QC 4414QC 4420QC
2 4410QC-2 4414QC-2 4420QC-2
3 4420QC-3
MODEL NOS. 4404QC 4410QC 4410QC-2 4414QC 4414QC-2 4420QC 4420QC-2 4420QC-3
DIMENSIONS:
EXTERIOR
(mm)*
Length A 24-1/4" (616) 26-3/4" (680)
Width B” 17-1/4" (439) 20-1/4" (515)
Height C 25-1/2" (648) 31" (788)
* A minimum of six inches of clearance should be allowed around the entire unit for proper performance. Additional Clearance should be considered for above the
unit and in front of the unit for serviceability.
ELECTRICAL Voltage 120V 115-208/230V **
Frequency 60 Hz
Phase 1 Ø
RLA (Rated
Load Amps) 14.4 15.7 21.8 20.6 26.2 21.9 24.7 27.5
MCA (Min. Circuit
Ampacity) 16.4 18.0 24.1 24.0 29.6 26.6 29.2 32.0
MOCP (Max. Over-
Current Protection) 20 25 30 35 40 40 45 50
COMPRESSOR (Horse Power) 1/3 1/2 3/4 1-1/2
EVAPORATOR RATING @ 20°F (BTUH) 2550 3800 6000 12000
HEAT of REJECTION MAX (BTUH) 4080 6080 9600 19200
REFRIGERATION Constant Pressure Expansion Valve, Condensing Unit with Service Valves
REFRIGERANT (TYPE) R-134a
REFRIGERANT CHARGE 14.0 oz/397g 12.0 oz/340g 14.0 oz/397g 16.0 oz/454g
SHIPPING WEIGHT LBS (kg) 140 (64) 138 (63) 150 (69) 167 (76) 180 (82) 217 (99) 230 (105) 245 (112)
CABINET Black Vinyl Clad Galvanized Steel
CIRCULATING PUMP 70 GPH / 80 PSIG (MAX)
RESERVOIR CAPACITY 1.75 Gallons
GLYCOL CONCENTRATION 30%
OPTIONAL ACCESSORIES
(Sold Separately)
C22296A-20 - Power Cord Kit for 4404QC & 4410QC Single Pump Units Only (NEMA 5-20P)
57782 - Adjustable Legs (Set of 4)
61468 - Overow Bottle Kit
63299-1 - Food Grade Glycol Pre-Mix (1 gallon)
61790A2 - Dual Tier Rack
61790A3 - Triple Tier Rack
C21499SS - Stainless Steel Table Stand
4408SS - Wall Bracket for 4404QC & 4410QC Only
**4-WIRE AC POWER SOURCE REQUIRED
AC - 115-208/240V, 60Hz, Split Single Phase
(Ground, Neutral, Hot-Power, Hot-Power)
Perlick is committed to continuous improvement. Therefore, we reserve the right to change specications without prior notice
2
4400QC SERIES POWER PAKS AIR COOLED
INSTALLATION AND OPERATING INSTRUCTIONS
WARNING: California Prop 65 Noce
These products may expose you to chemicals including
Chromium, which are known to the state of California
to cause cancer and birth defects or other reproducve
harm. For more informaon on whether a product in this
list contains these chemicals, please refer to the specic
product page at perlick.com. Or to nd out more about
Prop 65, go to P65Warnings.ca.gov.
C
US
Perlick is committed to continuous improvement. Therefore, we reserve the right to change specications without prior notice
3Form No. Z0507QC
Rev. 06.01.23
4400QC SERIES POWER PAKS - AIR COOLED
GENERAL INFORMATION
PRODUCT DESCRIPTION
Power Paks have always been an integral part of a Beer
System. The 4400QC Series Power Pak product line has
been expanded to satisfy longer beer runs. A Power Pak
circulates coolant solution (food grade propylene glycol with
distilled water) from the walk-in cooler to the dispensing
station(s) and back, maintaining the desired dispensing
temperature at the faucet. The 4400QC Series Power Paks
incorporate a 1/3 hp ball bearing, maintenance free motor
with a 70 gallon per hour 80 psig positive displacement
pump for optimum performance. The 4400QC series
Power Pak product line employs a direct expansion form
of refrigeration increasing the units efficiency as well as
making the units more compact. These units also employ
an electronic temperature control with digital readout. This
state of the art control, controls the performance of the unit
as well as giving the user a visual indication of how the unit
is working as well as early indication if something may be
going wrong through the use of internal alarms.
Accessories
Power Cord Kit
C22296A-20 – 12/3 Cord, 20A, Nema Plug 5-20P,
Dedicated Circuit Models – See electrical specifications.
NOTE: Use only with 4404QC and 4410QC Single Pump units only.
Power Pak Racks
61790A2 Dual Tier Rack, 61790A3 Triple Tier Rack
All Models
Power Pak Wall Mounting Brackets
4408SS For Models 4404QC and 4410QC only
Coolant Solution 63299-1
Food Grade Glycol Pre-Mix (1 Gallon)
Coolant Connector Kit
C23015 All Models
Leg Set All Models
57782 – Set of four, 5 3/ ”-7 41/2adjustable legs
INSTALLATION 4400QC Series Power Paks
IMPORTANT SAFETY WARNINGS!
• Follow all National and Regional Codes.
• Read Installation and Operating Instructions carefully before attempting to install, operate or maintain the product.
• Protect yourself and others by observing all safety information.
• Electrical hazards exist and can cause injuries if not serviced by properly trained personnel.
• Failure to comply with instructions could result in personal injury and/or property damage!
• Retain instructions for future reference.
• Never operate the circulating pump without coolant in the reservoir.
NOTE: Air-cooled Power Paks must be installed in areas with adequate ventilation to maintain ambient temperatures
of less than 105°F to achieve optimum performance and satisfy warranty requirements.
INSTALLING THE POWER PAK
Prior to installing a 4400QC Series Power Pak, it is imperative that the method of connecting it to the electrical service has been
determined. Ensure that the electrical service to power the Power Pak will handle the load requirements. Perlick has a Power
Cord specifically designed for a Power Pak, which has a RLA of 16 amps or less, and a MCA of 20 amps or less. All units with
RLA greater than 16 amps and a MCA of greater than 20 amps should have the Power Pak hard-wired to electrical service.
PRODUCT/SERVICE/WARRANTY INFORMATION
To Obtain Product Information
Contact your selling dealer.
Inquire on the web at perlick.com.
Call 800-558-5592 for factory assistance for information,
planning, installation or product information.
Write Perlick Corporation, Customer Service Department,
8300 W. Good Hope Road, Milwaukee, Wisconsin 53223.
E-mail us at warrantyserv@perlick.com.
To Obtain Product Service, Replacement Parts or Accessories:
Use only genuine Perlick replacement parts and accessories. Genuine
Perlick parts and accessories are designed to work correctly with
Perlick products and oer superior service life. The use of non-Perlick
parts can damage the unit and may void the warranty.
Check the model and serial number of the unit located on the label
attached to the inside top of the cabinet.
Call a Perlick Factory Authorized service center. For the location of the
nearest Service Center, contact your dealer, or inquire via the web at
perlick.com, or write to:
Perlick Corporation, Customer Service Department,
8300 W. Good Hope Road, Milwaukee, Wisconsin 53223,
call 800-558-5592, or e-mail us at:
warrantyserv@perlick.com.


Product specificaties

Merk: Perlick
Categorie: Niet gecategoriseerd
Model: 4414QC-2

Heb je hulp nodig?

Als je hulp nodig hebt met Perlick 4414QC-2 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Niet gecategoriseerd Perlick

Handleiding Niet gecategoriseerd

Nieuwste handleidingen voor Niet gecategoriseerd