Manual
Noise Meter PCE-318
PCE Americas Inc.
711 Commerce Way
Suite 8
Jupiter
FL-33458
USA
From outside US: +1
Tel: (561) 320-9162
Fax: (561) 320-9176
info@pce-americas.com
www.pce-instruments.com/english
www.pce-instruments.com
PCE Instruments UK Ltd.
Units 12/13
Southpoint Business Park
Ensign way
Hampshire / Southampton
United Kingdom, SO31 4RF
From outside UK: +44
Tel: (0) 2380 98703 0
Fax: (0) 2380 98703 9
info@industrial-needs.com
β… 
β… β… 
β… 
. FOR SAFETY
 Read the following safety information carefully before
attempting to operate or service the meter.
 Use the meter only as speciξ‹ˆed in this manual;
otherwise, the protection provided by the meter may be
impaired.
Environment conditions
ξ˜‚ Operation temperature : –10 C to +50 CΒ° Β°
ξ˜ƒ Operation humidity : 30% to 90%RH (non-condensing)
Maintenance & Clearing
ξ˜‚ Repairs or servicing not covered in this manual should
only be performed by qualiξ‹ˆed personnel.
ξ˜ƒ Periodically wipe the case with a dry cloth.
Do not use abrasives or solvents on this instruments.
Safety symbols
Comply with EMC
U.S. Pat. No. Des. 483,680
β…‘
β…‘β…‘
β…‘
. PRECAUTIONS
 Do not try to remove the microphone grid, you can easily
damage the microphone in this way.
 Protect the meter from impact, Do not drop it.
Transport it in the supplied carrying case.
 Protect the meter from shocks and vibration.
 Protect the meter from water, dust, extreme temperature,
humidity and direct sunlight during storage and use.
-1-
 Protect the meter away from air with high salt or sulphur
content, gases and stored chemicals.
 Always turn the unit o after use. Remove the battery
from the meter if it is not to be used for a long time.
 Clean the meter only by wiping it with a soft, dry cloth or,
when necessary, with a cloth lightly moistened with
water. Do not use any solvents, cleaning alcohol or
cleaning agents.
β…’
β…’β…’
β…’
. FEATURES
The meter contains several features that enable you to take
and save sound level measurements under a variety of
conditions.
Features include :
 Easy of use.
 Easy to read large display.
 Six measurement ranges.
 Fast and slow time weightings.
 A and C frequency weightings.
 L, Lmax and Lmin three measured parameters are
monitored during measurement and can be viewed
selectively by pressing the MAX key.
 Storage of up to 99 data sets for L, Lmax and Lmin with
elapsed time.
 Both AC and DC signal output is available from a single
standard 3.5mm coaxial socket suitable for a frequency
analyzer, level recorder, FFT analyzer, graphic recorder;
etc.
-2-
β…£
β…£β…£
β…£
. PARAMETERS
The following parameters are used on the meter.
 L
A
: β€œA” frequency weighting sound pressure level.
 L
C
: β€œC” frequency weighting sound pressure level.
 FAST : Fast time weighting.
 SLOW : Slow time weighting.
 max : Maximum sound pressure level.
 min : Minimum sound pressure level.
 β€œmax” ash : Tests time weighting characteristics.
The default settings of the meter are listed below.
Time weighting : FAST
Frequency weighting : A
Level range : 60 to 120dB
β…€β…€β…€β…€
. SPECIFICATIONS
Applicable standards: IEC61672-1 : 2002 Class 2
IEC60651 : 1979 Type 2
ANSI S1.4 : 1983 Type 2
Measurement functions
Main processing functions
Simultaneous measurement of all items according to
selected time weighting and frequency weighting.
Sound level L
A
or L
C
Maximum sound level L
A
max or L
C
max
Minimum sound level L
A
min or L
C
min
Total range : 30 to 130dB
Max. measurement level : 130dB
-3-