Panduit FPONE4 Handleiding


Lees hieronder de 📖 handleiding in het Nederlandse voor Panduit FPONE4 (2 pagina's) in de categorie Niet gecategoriseerd. Deze handleiding was nuttig voor 3 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/2
For Technical Support: www.panduit.com/resources/install_maintain.asp
INSTALLATION INSTRUCTIONS
© Panduit Corp. 2020 FS157
Page 1 of 2
Fiber PON Enclosure
Part Number(s): FPONE4
Bottom
Front
Back
SPECIFICATIONS:
Material: SMC, water resistant, dust-proof, IP55
Dimension (HxWxD): 458 x 400 x 135 mm
Color: Light Gray
Adapter Type: SC or FC
Number of Adapters: Max 64
Number of Splitters: Max 1 (N x 2, N x 4, N x 8, N x 16, and N x 32) and Max 1(N x 64)
Single Fusion Capacity: Max 64
The fiber radius of curvature is over 40 mm.
Wall Mount
Lid
Drop Cable
OSP Cable Entry
Spliiter and Splice
Storage
Adapter Storage
Product Structure and Cable Entry
E-mail:
techsupport@panduit.com
Phone:
866-405-6654
For Instructions in Local Languages
and Technical Support:
www.panduit.com/resources/install_maintain.asp
INSTALLATION INSTRUCTIONS
© Panduit Corp. 2020 FS157
www.panduit.com
Page 2 of 2
1. FInd the mounting screws and hardware included in the product packaging.
2. Drill holes as needed and use expansion hardware as needed. Use the mounting screws to fasten the enclosure
to the wall.
3. Route the drop cables through the attachment hardware on the bottom right hand side of the base. Then route
the drop cables around the base of the enclosure so that they enter onto the front of the flip tray.
4. Attach the connectorized end into the adapters. Match the adapter number with the appropriate cable number.
Enclosure Installation and drop cable attachment
Pigtail Installation
Pigtails with connectors on one end should have connectorized end attached to the adapter located in the adapter
storage. The pigtail fiber ends will need to be routed to the to the splice storage panel and prepared for splicing.
Splitter Installation
5. Splitters are available with connectorized or with bare fibers. If the splitter is connectorized, then attach the
connectors to the adapter located in the adapter storage. from the breakout side first, one at a time.
6. Then attach the splitter on the rear of the flip tray.
Outside Plant Cable Installation
7. The outside plant cable is routed into the bottom left hand corner of the base and attached inside the bracket at
the base of the enclosure.
8. The cable is to be prepped with 38 inches of exposed unit tube that is routed in the base of the enclosure and
routed to the fiber storage around the splice storage.
9. The unit tube that will be spliced is to be prepped by stripping to expose 18 inches of the fiber that will be
spliced to the pigtail.
10. Once the fusion splice is completed cover with the splice sleeve, it should be installed in the splice storage,
and then the fiber slack is routed around the fiber storage.


Product specificaties

Merk: Panduit
Categorie: Niet gecategoriseerd
Model: FPONE4
Kleur van het product: Wit
Breedte: 485 mm
Diepte: 135 mm
Hoogte: 400 mm
Internationale veiligheidscode (IP): IP69

Heb je hulp nodig?

Als je hulp nodig hebt met Panduit FPONE4 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Niet gecategoriseerd Panduit

Handleiding Niet gecategoriseerd

Nieuwste handleidingen voor Niet gecategoriseerd