Ozito WDVB-1312 Handleiding

Ozito Stofzuiger WDVB-1312

Lees hieronder de 📖 handleiding in het Nederlandse voor Ozito WDVB-1312 (8 pagina's) in de categorie Stofzuiger. Deze handleiding was nuttig voor 45 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/8
Angled Nozzle, Concentrator
Nozzle, Crevice Tool, Floor Tool &
2 x Extension Tubes
1.8m Hose, Foam Filter & Cartridge
Filter & Lid
Shoulder Strap & Mounting Ring,
Noise Diffuser, Blower Adaptor &
4 x Castor Wheels
2-IN-1
WET & DRY
VACUUM / BLOWER
1300W 30L / 360KM/H
INSTRUCTION MANUAL
SPECIFICATIONS
Mains Voltage: 220–240V ~ 50-60Hz
Input Power: 1300W
Max. Suction Power: 120mbar
Inlet Air Flow: 45-60L/s
Tank Capacity: 30L
Max. Air Speed: 360km/hour
Hose Diameter: Ø64mm
Hose Length: 1.8m
Weight: 8.4kg
WDVB-1312
STANDARD EQUIPMENT
IN ORDER TO MAKE A CLAIM UNDER THIS
WARRANTY YOU MUST RETURN THE PRODUCT
TO YOUR NEAREST BUNNINGS WAREHOUSE WITH
YOUR BUNNINGS REGISTER RECEIPT. PRIOR TO
RETURNING YOUR PRODUCT FOR WARRANTY
PLEASE TELEPHONE OUR CUSTOMER SERVICE
HELPLINE:
Australia 1800 069 486
New Zealand 0508 069 486
3 YEAR REPLACEMENT WARRANTY
Your product is guaranteed for a period of 36 months from
the original date of purchase. If a product is defective it will
be replaced in accordance with the terms of this warranty.
Warranty excludes consumable parts, for example: valve adapters
and accessories.
WARNING
The following actions will result in the warranty being void.
If the tool has been operated on a supply voltage other
than that specified on the tool.
If the tool shows signs of damage or defects caused
by or resulting from abuse, accidents or alterations.
Failure to perform maintenance as set out within the
instruction manual.
If the tool is disassembled or tampered with in any way.
Professional, industrial or high frequency use.
WARRANTY
TO ENSURE A SPEEDY RESPONSE PLEASE
HAVE THE MODEL NUMBER AND DATE OF
PURCHASE AVAILABLE. A CUSTOMER SERVICE
REPRESENTATIVE WILL TAKE YOUR CALL
AND ANSWER ANY QUESTIONS YOU MAY
HAVE RELATING TO THE WARRANTY POLICY
OR PROCEDURE.
OZITO Australia/New Zealand (Head Office) 1-23 Letcon Drive, Bangholme, Victoria, Australia 3175.
The benefits provided under this warranty are in addition
to other rights and remedies which are available to you at law.
Our goods come with guarantees that cannot be excluded
at law. You are entitled to a replacement or refund for a major
failure and for compensation for any other reasonably foreseeable
loss or damage. You are also entitled to have the goods repaired
or replaced if the goods fail to be of acceptable quality and the
failure does not amount to a major failure.
Generally you will be responsible for all costs associated with
a claim under this warranty, however, where you have suffered
any additional direct loss as a result of a defective product you
may be able to claim such expenses by contacting our customer
service helpline above.
ozito.com.au
2-in-1 Wet & Dry Vacuum/ Blower
0919
ONLINE MANUAL
Scan this QR Code with
your mobile device to take
you to the online manual.
Attaching The Feet & Castors
1. Press in the tabs on the latches to
release the tank lid.
2. Remove the tank lid and empty the tank
of all accessories.
3. Turn the tank upside down and
insert a castor foot into the slot on
the side of the tank.
4. Insert a screw into the hole
and tighten with a Philips head
screwdriver (not supplied).
5. Repeat steps 3 & 4 with the other 3 castor wheels.
6. Turn the tank right side up and replace the lid.
Note: Always ensure that the latch tabs have clicked back into place
and the tank lid is securely attached.
Noise Di󰀨user
The di󰀨user can be used
for quieter operation during
vacuuming.
1. Insert the locking end onto the
blower port and turn clockwise
to lock it into place.
Attaching The Blower Strap
For easier usage, the strap can be used to carry the Blower unit on
your shoulder when it is detached from the vacuum tank.
1. Insert one end of the
mounting ring into the blower
unit and pull the other end
around the front of the unit.
2. Attach the clip on the strap to
the mounting ring. Adjust the
strap as necessary.
1. Cord Hook
2. Blower Release Button
3. Carry Handle
4. On/O󰀨 Button
5. Strap Mounting Ring
6. Concentrator Nozzle
7. Blower Port
8. Noise Di󰀨user
9. Blower Intake Lid
10. Floor Tool
11. Angled Nozzle
12. Castor Wheel
13. Vacuum Tank
14. Lid Latch
15. Accessory Storage Slot
16. Drain Outlet Cap
17. Vacuum Port
18. Tank Lid
19. Crevice Tool
20. Extension Tube
2-IN-1 WET & DRY VACUUM / BLOWER
ACCESSORIES
KNOW YOUR PRODUCT
1. ASSEMBLY
SETUP & PREPARATION
21. 1.8m Hose
22. Foam Filter
23. Cartridge Filter & Lid
24. Blower Adaptor
a.
b.
a.
b.
2
15
16
19
18
20
17
9
1
21 22 23 24
3
75 64
14
10
8
11
12
13
WARNING! ENSURE THE TOOL IS TURNED OFF
AND DISCONNECTED FROM THE POWER SUPPLY
BEFORE PERFORMING ANY OF THE FOLLOWING
OPERATIONS.
Fitting the Cartridge Filter - Vacuuming Dry Matter
The cartridge lter should come pre-assembled onto the vacuum unit.
However it is still a good idea to check that it has not come loose
during transport and is still properly tted before use.
For dry vacuum cleaning always
use the cartridge lter. Mount
the lter so that no air is sucked
through the lter cage without
rst being ltered.
1. Press the at end of the
cartridge lter onto the lter
cage until it is stopped by the
step in the lid part.
2. Place the lter lid on the
bottom of the lter and turn
the handle clockwise to lock it
into place.
3. To remove the lter, turn the lter lid handle anti-clockwise to
release it. Remove both the lter lid and cartridge lter.
NOTE: Do not use the foam lter when vacuuming dry matter.
Fitting the Foam Filter - Vacuuming Liquid
For wet-vacuuming, slip the
supplied foam lter over the lter
cage.
NOTE: Do not use the cartridge
lter when vacuuming liquid.
WARNING! SWITCH OFF THE EQUIPMENT IF LIQUID
OR FOAM IS EMITTED WITH THE EXHAUST AIR
WHEN WET VACUUM CLEANING.
WARNING! THE WET & DRY VACUUM IS NOT
SUITABLE FOR THE VACUUMING OF COMBUSTIBLE
LIQUIDS.
WARNING! WHEN WET VACUUMING, THE
SAFETY FLOAT STOPS THE VACUUM SUCTION
AUTOMATICALLY WHEN THE MAXIMUM CAPACITY
IS REACHED. TURN OFF THE VACUUM & EMPTY
THE TANK BEFORE CONTINUING TO VACUUM.
Draining Liquids From The Tank
Spills and puddles can be vacuumed directly into the tank with the
foam lter tted for easy clean up and disposal.
Note: When vacuuming large quantities of liquid, do not immerse the
nozzle completely into the liquid, leave a gap at the nozzle/tool to
allow air inow.
1. Hold the vacuum over a laundry sink or household drain.
Note: Only dispose of liquid waste into household sinks & drains
if safe to do so. Improper disposal of hazardous waste can cause
pollution and harm.
2. Turn the drain outlet cap
anti-clockwise to loosen and
remove it.
3. Allow any collected liquid
in the tank to ow out.
Tip the vacuum slightly
to allow any liquid at the
bottom of the tank to ow
out too.
4. Rinse out the tank if
necessary and replace the
drain outlet cap.
2. FILTER SELECTION 3. WASTE DISPOSAL
a.
b.
c.
WARNING! NEVER USE THE WET & DRY VACUUM
CLEANER WITHOUT A FILTER. ALWAYS ENSURE
THAT THE FILTERS ARE PERFECTLY SECURE.


Product specificaties

Merk: Ozito
Categorie: Stofzuiger
Model: WDVB-1312

Heb je hulp nodig?

Als je hulp nodig hebt met Ozito WDVB-1312 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Stofzuiger Ozito

Handleiding Stofzuiger

Nieuwste handleidingen voor Stofzuiger