Multi-Channel IN-OUT Thermometer
with Cable Free Sensor and RF Clock
MODEL: RMR112
USER'S MANUAL
INTRODUCTION
Congratulations on your purchase of the RMR112 Multi-Channel
In-Out Thermometer with 433MHz cable free sensor and
radio-controlled calendar clock.
The basic package comes with a main unit, which is the
temperature and calendar clock station, and a remote unit, the
thermo sensor.
The main unit has large read-outs for indoors temperature,
calendar clock and temperatures collected and transmitted by the
remote unit. The main unit can support up to three remote units.
The main unit is capable of keeping track of the maximum and
minimum temperature of different sites. And no wire installation
is required and the RMR112 operates at 433MHz.
As for the calendar clock, it is radio-controlled. It automatically
synchronizes its current time and date when it is brought within an
approximate 1500km radius of the radio signal generated from
Frankfurt, Germany (DCF77).
You can also set the calendar clock manually when it is off range.
Other features include four-language display, four-step crescendo
dual alarms and interchangeable display modes.
MAIN FEATURES
505ξ€€ξ€€ξ€€B(1B5ξ€€ξ€€ 9/9/04, 9:36 PM1
2
EN
A. FOUR-LINE DISPLAY
Facilitates easy reading of remote and indoors temperatures
and calendar clock
B. CHANNEL BUTTON
Selects among different channels
C. MEMORY BUTTON
Recalls the maximum or minimum temperature of individual
channels
D. ALARM [24HR OFF] BUTTON
Sets the time for the alarms
E. MODE/SET BUTTON
Toggles the display modes and confirms entry while setting
the values for display
F. RADIO RECEPTION SIGNAL
Indicates the condition of radio reception
G. UP ( β–² ) BUTTON
Advances the value of a setting
H. DOWN ( β–Ό ) BUTTON
Decreases the value of a setting
I. ALARM [ AL ON/OFF] BUTTON
Enables or disables the alarms
J. RESET BUTTON
Returns all settings to default values
K. Β°C/Β°F SLIDE SWITCH
Selects between degree Centigrade ( C) and Fahrenheit (Β° Β°F)
L. BATTERY COMPARTMENTS
Accommodates two UM-3 or β€œAA” size 1.5V alkaline bat-
teries
M. REMOVABLE TABLE STAND
For standing the main unit on a flat surface
N. WALL-MOUNT RECESSED HOLE
For mounting the main unit on a wall
MAIN FEATURES: REMOTE UNIT
Made in PRC
505ξ€€ξ€€ξ€€B(1B5ξ€€ξ€€ 9/9/04, 9:36 PM2
3
EN
A. LCD
Displays the current temperature monitored by the remote unit
B. LED INDICATOR
Flashes when the remote unit transmits a reading
C. CHANNEL SLIDE SWITCH
Designates the remote unit Channel 1, Channel 2 or Channel 3
D. RESET BUTTON
Returns all settings to default values
E. BATTERY COMPARTMENT
Accommodates two AAA-size batteries
F. BATTERY DOOR
G. WALL-MOUNT RECESS HOLE
For mounting the main unit on a wall
H. MOVABLE TABLE STAND
For standing the remote unit on a flat surface
BEFORE YOU BEGIN
For best operation,
1. Assign different channels to different remote units.
2. Insert batteries for remote units before doing so for the main
unit.
3. Place the main unit as close as possible next to the remote unit,
reset the main unit after installing batteries. This will ensure
easier synchronization between the transmission and recep-
tion of signals.
4. Position the remote unit and main unit within effective trans-
mission range, which, in usual circumstances, is 20 to 30 meters.
Note that the effective range is vastly affected by the building
materials and where the main and remote units are positioned. Try
various set-ups for best result.
Though the remote units are weather proof, they should be placed
away from direct sunlight, rain or snow.
BATTERY AND CHANNEL
INSTALLATION: REMOTE UNIT
1. Remove the screws on the battery compartment.
2. Select the channel number on the CHANNEL slide switch.
3. Install 2 alkaline batteries (UM-4 or β€œAAA” size 1.5V) strictly
according to the polarities shown.
4. Replace the battery compartment door and secure its screws.
Note that once a channel is assigned to a remote unit, you can only
change it by removing the batteries or resetting the unit.
505ξ€€ξ€€ξ€€B(1B5ξ€€ξ€€ 9/9/04, 9:36 PM3


Product specificaties

Merk: Oregon Scientific
Categorie: Thermometer
Model: RMR112

Heb je hulp nodig?

Als je hulp nodig hebt met Oregon Scientific RMR112 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Thermometer Oregon Scientific

Handleiding Thermometer

Nieuwste handleidingen voor Thermometer