Morco GB24 Handleiding


Lees hieronder de 📖 handleiding in het Nederlandse voor Morco GB24 (8 pagina's) in de categorie CV Ketel. Deze handleiding was nuttig voor 156 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/8
GB24 & GB30
User Manual
To Domestic Hot Water:To Central Heating:
GB24/30 Minimum 8.0 kW (27,296 Btu/h) GB24/30 Minimum 8.0 kW (27,296 Btu/h)
GB24 Maximum 24.2 kW (82,570 Btu/h) GB24/30 Maximum 24.2 kW (82,570 Btu/h)
GB30 Maximum 30.3 kW (103,384 Btu/h)
Morco House, Riverview Road, Beverley, East Yorkshire, HU17 0LD
Morco Products Ltd
Tel:+44 (0) 1482 325456 Fax: +44 (0) 1482 212869
Website:www.morcoproducts.co.uk
UIN 209783 A03
April 2014
BOILER OUTPUT
Introduction
The is a wall mounted, room sealed, condensing combination boiler, featuring automatic spark Morco GB
ignition and fan assisted combustion. The is a combination boiler providing both central Morco GB
heating and instantaneous domestic hot water (DHW) for taps and showers.
Due to the high efficiency of the boiler, condensate is produced from the flue gases and this exits the
boiler through a plastic waste pipe at the base of the boiler. A condensate ‘plume’ will also be visible at
the flue terminal.
The boiler has a number of safety features that will stop it working when problems are detected. The fault
codes that are shown on the boiler status display problem. Once the fault is corrected the “D” identify the
boiler can be reset using the mode contro A list of fault codes can be found on page 8. l knob “A”.
The boiler features a preheat function that allows the boiler to occasionally fire on its own to keep the
water within the boiler hot. This improves the speed with which hot water is delivered to taps or showers.
This function can be switched off if required.
Safety
The boiler must be installed, commissioned and maintained to the standards relevant to the country in
which the home is located.
It is essential that the instructions in this booklet are strictly followed, for safe and economical
operation of the boiler.
Electricity Supply
This appliance must be earthed.
Supply: 230 V ~ 50 Hz. The fusing should be 3A.
Important Notes
This appliance must be operated with the front casing correctly fitted and forming an adequate seal.
the boiler is installed in a cupboard then the cupboard MUST NOT be used for storage purposes. If
If it is known or suspected that a fault exists on the boiler then it MUST NOT BE USED until the fault
has been corrected by a qualified and competent Gas Installer.
Under NO circumstances should any of the sealed components on this appliance be used incorrectly
or interfered with.
This appliance must be operated with supervision to ensure safe operation from the ages of 8 years
and above, including people with reduced physical, sensory or mental capabilities. Any maintenance
or cleaning shall not be completed without supervision.
Boiler Controls
Legend
A. Mode Control Knob
B. DHW/Preheat Control Knob
C. CH Control Knob
D. Boiler Status
E. Burner ‘ON’ Indication
F. Pre Heat on/off Indication
G. Programmer
H. Pressure Gauge
J. Condensate Drain
K. Gas Isolation Valve (on position
Shown)
In cases of repeated or continuous shutdown a qualified and competent Gas Installer, should be
called to investigate and rectify the condition causing this and carry out an operational test. Only the
manufacturer’s parts are to be used for replacement
Minimum Clearances around the Boiler
Clearances of above below, the sides and the front of the boiler 165mm , 100mm 2.5mm at 450mm at
casing must be allowed for servicing.
The clearance below the boiler can be reduced to 5mm after installation provided an easily removable
panel is fitted, to enable the consumer to view the system pressure gauge, and to provide the 100mm
clearance required for servicing.
Boiler Operation
To light the boiler
Refer to Boiler Controls Diagram
CHECK THAT THE ELECTRICITY SUPPLY TO BOILER IS OFF.
Set the mode control knob (A) to ‘off’.
Set the Domestic Hot Water temperature control (B) and Central Heating control knob (C) to ‘max’.
Ensure that all hot water taps are turned off.
Switch ON electricity to the boiler and check that all controls, e.g. boiler mechanical timer “G” and
optional room thermostat, are ON (refer to mechanical 24 hour timer instructions).
( Set the mode knob control (A) to winter ).
If there is central heating demand or if a hot tap is opened the boiler will ignite showing burner status (E).
Note. In normal operation in the Boiler Controls diagram) will show one the “boiler status display” (D) of
the following codes:
DISPLAY CODE ON BOILER
DESCRIPTION
status
Burner Off
The boiler is in standby mode awaiting either a central heating call or domestic hot water demand.
0
status
Burner Off
The boiler has a call for central heating but the appliance has reached the desired temperature set on
the boiler.
C
status
B Off urner
The boiler has a call for domestic hot water but the appliance has reached the desired temperature set
on the boiler.
d
status
B urner On
The boiler is operating in central heating mode.
C
status
B urner On
The boiler is operating in domestic hot water mode.
d
status
B urner On
The boiler is operating in pre heat mode.
P
status
B urner On
The water in the central heating circuit is less than 5ºC. If heating is switched on, this display code will
change to “c”. This indicates that the frost stat is in operation.
F


Product specificaties

Merk: Morco
Categorie: CV Ketel
Model: GB24

Heb je hulp nodig?

Als je hulp nodig hebt met Morco GB24 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden