Kospel EKD.M3 Handleiding
Lees hieronder de 📖 handleiding in het Nederlandse voor Kospel EKD.M3 (24 pagina's) in de categorie CV Ketel. Deze handleiding was nuttig voor 19 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld
Pagina 1/24
Assembly and operating instructions
Bi-functional Electric Central Heating Flow Boiler
EKD.M3
Used product can’t be treated as general communal waste.
Disassembled appliance has to be delivered to the collection
point of electrical and electronic equipment for recycling.
Appropriate utilisation of used product prevents potential
negative environmental inuences that may occur as a result
of inappropriate handling of waste. In order to get more detailed
information about recycling this product you should contact the
local government unit, waste management service or the shop
where this product has been purchased.
This appliance can be used by children aged from 3 years
and above and persons with reduced physical, sensory or
mental capabilities or lack of experience and knowledge if
they have been given supervision or instruction concerning
use of the appliance in a safe way and understand the
hazards involved. Children shall not play with the appliance.
Cleaning and user maintenance shall not be made by children
without supervision.
GB-088B_f. 3
Safety instructions
1. Read and strictly follow this installation and operating instructions to ensure a long
life and reliable boiler operation.
2. An efîš¿cient electrical installation which has been completed in accordance with the
binding norms.
3. Central heating system equipped with an appropriate expansion vessel completed
in accordance with binding norms of hydraulic installation.
4. Rinse the heating installation thoroughly before installing the boiler.
5. Do not install any barrier îš¿ttings (e.g. valves) on the outlet of the safety valve.
6. Boiler can only be installed on the at surface.
7. Boiler must not be installed in a humid place, in a place exposed to the danger of
explosion, or in which the temperature may drop below 0°C.
8. Boiler must be installed in such a place and in such a way in order not to ood the
room in case of the emergency water leak.
9. Boiler must be connected to water system and central heating system in accordance
with the manufacturer’s instructions. Failure to do so deprives the user from the
warranty rights and may cause device’s damage.
10. Installation of the device to the water supply must be compatible with all relevant
regulations in force.
11. Maximum pressure of the hot water storage must not exceed 0,3MPa. If system’s
pressure is higher than 0,6MPa, pressure reducing valve must be îš¿tted before
cylinder.
12. Water dripping from safety valves’ down pipe is a natural occurrence and it should
not be stopped, as its blockage may lead to the device’s failure.
13. It is forbidden to use the hot water storage if you suspect that safety valves may
be faulty.
14. The tank is equipped with a magnesium anode - an additional protection against
corrosion. The anode is an operating part, therefore, it is exposed to wear. The
condition of the magnesium anode should be controlled every 12 months, however,
it is due to be replaced with a new one every 18 months.
15. The boiler installation and electrical and hydraulic work must be performed by
a qualiîš¿ed professional installer in accordance with all instructions provided by the
manufacturer.
16. All installation work must be performed when the power and water supply are turned
off.
17. Electric installation should be equipped with residual current protective devices
and other solutions which will ensure disconnecting the heater from the source of
power (intervals between all their poles should not be less than 3mm).
18. Electronically controlled heater is a electrical surge sensitive device, therefore the
electrical installation must contain surge protection devices.
19. Do not drain the water from central heating system after the heating season.
20. Leave the controller in stand-by mode and do not cut off power supply between the
heating seasons. Proceeding otherwise may result in pump’s rotor blockage.
Product specificaties
Merk: | Kospel |
Categorie: | CV Ketel |
Model: | EKD.M3 |
Heb je hulp nodig?
Als je hulp nodig hebt met Kospel EKD.M3 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding CV Ketel Kospel
18 November 2024
Handleiding CV Ketel
- CV Ketel Bosch
- CV Ketel ATAG
- CV Ketel Junkers
- CV Ketel Nefit
- CV Ketel Remeha
- CV Ketel Vaillant
- CV Ketel A.O. Smith
- CV Ketel ACV
- CV Ketel AGPO
- CV Ketel AWB
- CV Ketel Brink
- CV Ketel Buderus
- CV Ketel Bulex
- CV Ketel Daalderop
- CV Ketel De Dietrich
- CV Ketel Elco
- CV Ketel Ferroli
- CV Ketel Intergas
- CV Ketel Itho
- CV Ketel Itho-Daalderop
- CV Ketel La Nordica
- CV Ketel Morco
- CV Ketel Nibe
- CV Ketel Saunier Duval
- CV Ketel Stiebel Eltron
- CV Ketel Thermona
- CV Ketel Truma
- CV Ketel Tzerra
- CV Ketel Viessmann
- CV Ketel Weishaupt
- CV Ketel Wolf
- CV Ketel Ygnis
- CV Ketel Oertli
- CV Ketel Baxi
- CV Ketel ROC
- CV Ketel Vokèra
- CV Ketel Worcester
- CV Ketel Fantini Cosmi
- CV Ketel Masterwatt
- CV Ketel Mikoterm
- CV Ketel Ariston Thermo
Nieuwste handleidingen voor CV Ketel
17 November 2024
17 November 2024
7 Augustus 2024
7 Augustus 2024
4 Maart 2024
23 November 2023
23 November 2023
23 November 2023
14 November 2023
14 November 2023