OPERATOR'S MANUAL
MANUEL de L'UTILISATEUR
MANUAL del OPERADOR
12 V Laser Temp-Gun™ Thermometers
Thermomètre laser Temp-Gun™ de 12 V
Termómetros láser Temp-Gun™ de 12 V
Cat. No.
No de Cat.
2276-20
2277-20
TO REDUCE THE RISK OF INJURY, USER MUST READ AND UNDERSTAND OPERATOR'S
MANUAL.
AFIN DE RÉDUIRE LE RISQUE DE BLESSURES, L'UTILISATEUR DOIT LIRE ET BIEN
COMPRENDRE LE MANUEL DE L'UTILISATEUR.
PARA REDUCIR EL RIESGO DE LESIONES, EL USUARIO DEBE LEER Y ENTENDER EL
MANUAL DEL OPERADOR.
2 3
LOG
MODE
SET
12V LASER TEMP-GUN
AVOID EXPOSURE
LASER RADIATION
IS EM ITTED FROM THIS APERTUR E
LASER R ADIATION - DO NOT STARE INTO BEAM
MAXIMUM POWER < 1m W WAVE LENGT H 630-670 nm
CLASS II LASER PRODUCT COMPLIES WITH 21 CFR 1040.10 AND 1040.11
C A UT IO N
CAT. NO . 2276-20
MADE IN CHINA
READ
OPERATORS
MANUAL
IMPORTANT SAFETY INSTRUCTIONS
WARNING READ ALL SAFETY WARNINGS AND INSTRUCTIONS. Failure to
follow the warnings and instructions may result in electric shock, re and/or serious injury.
Save these instructions - This operator’s manual contains important safety and operating
instructions for MILWAUKEE Laser Temp-Gun™ Thermometers. Before using the Temp-Gun™,
read this operators manual, your battery pack and charger operator’s manual, and all labels
on the battery pack, charger and Temp-Gun™.
FUNCTIONAL DESCRIPTION
PERSONAL SAFETY
LASER SAFETY
WORK AREA SAFETY
• Laser light - Do not stare into beam or view
directly with optical instruments. Do not point
laser light at others. Laser light can cause eye
damage.
Avoid exposure to laser radiation. Laser may
emit hazardous radiation.
• Do not point laser at re ective surfaces. Un-
predictable results may occur.
• Keep children and bystanders away while
operating Temp-Gun™. Store idle Temp-Gun
out of the reach of children and do not allow
persons unfamiliar with the tool or these in-
structions to operate them.
• Avoid dangerous environments. Do not use in
rain, snow, damp or wet locations. Do not use in
the presence of explosive atmospheres (gaseous
fumes, dust or ammable materials) because
sparks may be generated when inserting or re-
moving battery pack, possibly causing re.
• Stay alert, watch what you are doing and use
common sense when operating Temp-Gun™.
Do not use while you are tired or under the
in uence of drugs, alcohol or medication.
A moment of inattention may result in serious
personal injury.
• Do not overreach. Keep proper footing and
balance at all times. This enables better control
in unexpected situations.
BATTERY USE AND CARE
Under abusive conditions, liquid may be
ejected from the battery, avoid contact. If
contact accidentally occurs, ush with water. If
liquid contacts eyes, additionally seek medical
help. Liquid ejected from the battery may cause
irritation or burns.
SERVICE
• Have your Temp-Gun™ serviced by a quali ed
repair person using only identical replacement
parts. This will ensure that the safety of the tool
is maintained.
Do not disassemble. Incorrect reassembly may
result in the risk of electric shock or re. If it is dam-
aged, take it to a MILWAUKEE service facility.
• Store in a cool, dry place. Do not store where
temperatures may exceed 120°F (50°C) such as
in direct sunlight, a vehicle or metal building during
the summer.
Do not remove or deface labels. Maintain
labels and nameplates. These carry important
information. If unreadable or missing, contact
a MILW AU KEE service facility for a free
replacement.
Recharge only with the charger speci ed by
the manufacturer. A charger that is suitable for
one type of battery pack may create a risk of re
when used with another battery pack.
Use power tools only with speci cally desig-
nated battery packs. Use of any other battery
packs may create a risk of injury and re.
• When battery pack is not in use, keep it away
from other metal objects like paper clips,
coins, keys, nails, screws, or other small metal
objects that can make a connection from one
terminal to another. Shorting the battery termi-
nals together may cause burns or a re.
1. Display
2. K-Type thermocouple input
3. Key pad
4. Lock-on button
5. Nameplate
6. Laser window
Speci cations
Laser Type: Class II
Max Power: <1mW
Wavelength: 630-670 nm
IR Temperature range: -3C to 800°C (-22°F to 147F)
IR Accuracy: -30°C to 0°C (-22°F to 32°F): ±1.5°C (3°F) +0.1/1°C or F
0°C to 120°C (32°F to 248°F): ±1.0°C (2°F) +0.1/1°C or F
120°C to 380°C (24F to 71F): ±1.5°C (3°F) or 1.5% of reading, whichever is greater
380°C to 800°C (716°F to 1472°F): ±2°C (4°F) or 2% of reading, whichever is greater
Min. measuring distance: 2” < 50°C (122°F), 4” > 50°C (122°F)
Display resolution: 0.1°C/°F Primary and Secondary
Contact temp range: -40°C to 550°C (-40°F to 1022°F)
Contact temp input accuracy: ±1.1°C, ±2°F
Contact temp display resolution: 0.1°C/°F
K-Type Probe temp range: -40°C to 260°C (-40°F to 500°F)
K-Type Probe temp input accuracy: < 400°C ±2.5°C (< 752°F ±5°F)
Emissivity: Pre-set 0.95 (can be manually set)
RH Display (2277-20 only): 10%-90%
RH Accuracy (2277-20 only): ±5%
Response time: <500 msec
Drop: 1.5 meter
Log spaces: 20
Spectral response: 8 to 14 microns thermopile detector
Distance to spot: 40 to 1
Repeatability: ±0.5% OR ±1°C (±2°F) (whichever is greater)
Operating temperature: 0°C to 50°C (32°F to120°F)
Storage temperature: -20°C to 60°C (-4°F to 140°F) without battery
Relative humidity: 10 to 90% RH non-condensing at <30°C (<86°F) ambient
Voltage: 12 DC
Battery run time: Greater than 12 hrs with all functions
LOG
MODE
SET
13. Log
14. Settings
15. Backlight on/off
16. Arrow down
11
12
13
15
16
17
14
4
2
1
3
5
6
7
8
9
10
20
19
18
22
21
23
26
24
25
28
27
29
7. Infrared sensor
8. LED Floodlight
9. Trigger
10. Battery pack
11. Alarm on/off
12. Arrow up
17. Operation modes
18. Battery life indicator
19. Laser active indicator
20. Emissivity active indicator
21. Alarm indicator
22. Hold indicator
23. C° or F° indicator
24. Primary measurement
25. Humidity indicator
26. Trigger lock indicator
27. Secondary measurement
28. Log indicator
29. Emissivity value
Federal Communications Commission
WARNING: Changes or modi cations to this unit not ex-
pressly approved by the party responsible for compliance
could void the user’s authority to operate the equipment.
This equipment has been tested and found to comply with
the limits for a Class B digital device, pursuant to Part 15
of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a
residential installation. This equipment generates, uses
and can radiate radio frequency energy and, if not installed
and used in accordance with the instructions, may cause
harmful interference to radio communications.
However, there is no guarantee that interference will not
occur in a particular installation. If this equipment does
cause harmful interference to radio or television reception,
which can be determined by turning the equipment off and
on, the user is encouraged to try to correct the interference
by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and
receiver.
• Connect the equipment into an outlet on a circuit different
from that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician
for help.
12V LASER TEMP-GUN
AVOID EXPOSURE
LASER RADIATION
IS EMITTED FROM THIS APERTURE
LASER RADIATION - DO NOT STARE INTO BEAM
MAXIMUM POWER < 1mW WAVE LENGTH 630-670 nm
CLASS II LASER PRODUCT COMPLIES WITH 21 CFR 1040.10 AND 1040.11
C AU T IO N
CAT. NO. 2277-20
MADE IN CHINA
READ
OPERATORS
MANUAL
5
4 5
Selecting MODES
Press the MODE button to display one of the fol-
lowing:
Average Temperature (AVG)
During a temperature reading,
the average temperature read
during the scan is displayed.
Maximum Temperature (MAX)
During a temperature reading,
the highest temperature read
during the scan is displayed.
Minimum Temperature (MIN)
During a temperature reading,
the lowest temperature read
during the scan is displayed.
Humidity (HUM)-2277-20 only
During a temperature reading,
the relative humidity (RH%) read
during the scan is displayed.
The relative humidity is taken at
the meter, not at the point of the
temperature reading.
Dew Point Temperature
(DEW)
During a temperature reading,
the dew point read during the
scan is displayed. The dew
point is taken at the meter, not
at the point of the temperature
reading.
OPERATION
WARNING Always remove battery
pack before changing or removing acces-
sories. Only use accessories specifically
recommended for this tool. Others may be
hazardous.
Scanning Object IR Temperature
1. Pull and hold the trigger for at least 2 seconds
and scan the surface temperature of an object.
A laser pointer indicates the center of the circular
area being scanned.
NOTE: The object should be larger than the spot
being scanned. If not, readings will be affected.
See Distance To Spot for necessary object size.
Distance to Spot 40:1
At 120" (10') away,
spot is 3" in diameter
At 80" away,
spot is 2" in diameter
At 40" away,
spot is 1" in diameter
—— Center of Spot
– – – Laser pointer (approx. 3/4" above center of spot)
Spot size at distance indicated
2. As you continue to hold
the trigger, the icon is
displayed along with the sur-
face temperature (primary
measurement) along with
any selected mode readings
(secondary measurement).
3. Release the trigger. HOLD
is displayed until the screen
shuts off in about seven sec-
onds.
NOTE: A quick change in tem-
perature affects the unit’s read-
ings. Allow unit to reach ambient
temperature before use.
ASSEMBLY
WARNING Recharge only with the
charger speci ed for the battery. For speci c
charging instructions, read the operator’s
manual supplied with your charger and
battery.
Inserting/Removing the Battery
To remove the battery, push in the release buttons
and pull the battery pack away from the tool.
To insert the battery, slide the pack into the body of
the tool. Make sure it latches securely into place.
Symbology
Volts Direct Current
CAUTION Laser Light - Do Not
Stare Into Beam
Laser product
Avoid Exposure: Laser Radiation Is
Emitted From This Aperture
To reduce the risk of injury, user must
read operator’s manual.
WARNING Never connect the Tem-
perature Probe to an energized circuit.
Contact Temperature Measurement with K-Type
Probe
Only use K-type Temperature Probes with this
meter.
1. Insert the probe. The unit
detects a connection of a K-
type probe and displays the
contact temperature (CON)
as the secondary measure-
ment.
2 The display will continue
to update the contact tem-
perature (CON) while the
temperature probe reaches
thermal equilibrium with the
object being measured. The
display will shut off after
about 20 minutes.
3. To take an IR reading while
using the K-type probe, pull
the trigger. The IR reading is displayed as the
primary measurement.
4 If set, the alarm will alert for the contact tem-
perature when the sensor probe is installed.