Milwaukee 2217-20 Handleiding


Lees hieronder de 📖 handleiding in het Nederlandse voor Milwaukee 2217-20 (15 pagina's) in de categorie Multimeter. Deze handleiding was nuttig voor 44 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/15
OPERATOR'S MANUAL
MANUEL de L'UTILISATEUR
MANUAL del OPERADOR
TO REDUCE THE RISK OF INJURY, USER MUST READ AND UNDERSTAND OPERATOR'S
MANUAL.
AFIN DE RÉDUIRE LE RISQUE DE BLESSURES, L'UTILISATEUR DOIT LIRE ET BIEN
COMPRENDRE LE MANUEL DE L'UTILISATEUR.
PARA REDUCIR EL RIESGO DE LESIONES, EL USUARIO DEBE LEER Y ENTENDER EL
MANUAL DEL OPERADOR.
TRUE RMS MULTIMETER (DMM)
MULTIMÈTRE D'EFFICACITÉ VÉRITABLE (DMM)
MULTÍMETRO CON RMS VERDADERO (DMM)
Cat. No.
No de cat.
2217-20
23
IMPORTANT SAFETY INSTRUCTIONS
WARNING READ ALL SAFETY WARNINGS AND INSTRUCTIONS. Failure to
follow the warnings and instructions may result in electric shock, re and/or serious
injury, as well as instrument damage and/or damage to the equipment being tested. Save these
instructions - This operators manual contains important safety and operating instructions
for the MILWAUKEE True RMS Multimeters (DMM). Before using, read this operators manual
and all labels on the True RMS Multimeters.
DANGER
Never make measurement on a circuit in which voltage over 600V rms exists. Use only leads
rated 600V CATIII or better.
Do not apply more than the rated voltage, as marked on the DMM, between terminals or be-
tween any terminal and earth ground.
Do not attempt a current measurement when the open voltage is above the fuse protection
rating. Suspected open circuit voltage can be checked with voltage function.
Do not use the DMM to measure voltages in circuits that could be damaged by the DMM’s low
input impedance in Lo-Z Function. Impedance is approximately 4K .Ω
Do not attempt to make measurement in the presence of ammable gases. Otherwise, the use
of the instrument may cause sparking, which can lead to an explosion.
Never attempt to use the instrument if its surface or your hand is wet.
Do not exceed the maximum allowable input of any measuring range.
Only test on unenergized circuits unless absolutely necessary.
Check tool functionality on a known circuit rst. Never assume tool is working. Assume circuits
are live until they can be proven de-energized.
Never open the Battery cover during a measurement.
Do not ground yourself while measuring. Avoid body contact with earthed or grounded sur-
faces such as pipes, radiators, ranges and refrigerators.
This instrument is to be used only in its intended applications or conditions. Otherwise, the instru-
ment's safety functions may not work, resulting in serious personal injury and instrument damage.
To reduce the risk of injury from shock and arc blasts, always wear personal protective
equipment where live conductors are exposed.
WARNING
Never attempt to make measurement if any abnormal conditions, such as broken case and
exposed metal parts are found on the instrument.
Comply with local and national safety requirements when working in hazardous locations.
Keep ngers behind the guards and away from test lead tips during measurements.
Do not rotate the Rotary Dial while the test leads are being connected.
Never attempt a voltage measurement with the test lead inserted into the A input terminal.
Verify proper operation on a known source before use or taking action as a result of the in-
dication of the instrument.
Do not install substitute parts, replace fuse or make any modi cation to the instrument. For
repair or re-calibration, return the tool to a factory Service/Sales Support Branch or authorized
service station.
Do not try to replace the batteries if the surface of the instrument is wet.
Disconnect all the cords and cables from the object under test and power off the instrument
before opening the Battery Cover for Battery replacement.
This tool is designed to be powered by 2-AA batteries properly inserted into the MILWAUKEE
True RMS Multimeters. Do not attempt to use with any other voltage or power supply.
Install battery according to polarity (+ and –) diagrams.
Do not leave batteries within the reach of children.
Do not mix new and used batteries. Do not mix brands (or types within brands) of batteries.
Properly dispose of used batteries.
Do not incinerate or dismantle batteries.
Under abusive conditions, liquid may be ejected from the battery, avoid contact. If contact
accidentally occurs, ush with water. If liquid contacts eyes, additionally seek medical help.
Liquid ejected from the battery may cause irritation or burns.
45
CAUTION
Set the Rotary Dial to an appropriate position before starting measurement.
Disconnect test leads from test points before changing Rotary Dial functions.
Never connect to a source of voltage with the Dial function in OFF/ / / / / / .Ω
Firmly insert the test leads.
Do not expose the instrument to the direct sun, high temperature and humidity or dew fall.
Altitude 2000m or less. Appropriate operating temperature is within -10ºC and 50ºC.
Keep away from excess dust and water.
Be sure to power off the instrument after use. When the instrument will not be in use for a long
period, place it in storage after removing the batteries.
Use a damp cloth or neutral detergent for cleaning the instrument. Do not use abrasives or
solvents.
Accuracy is speci ed for 1 year after calibration, at operating temperatures of 18°C to 28°C (64°F to
82°F), with relative humidity at 45 % to 85 %.
General Speci cations
FUNCTIONAL DESCRIPTION
1. Display
2. Range button
3. °F/°C button
4. Backlight button
5. VΩ Terminal input
6. COM Terminal input
7. A mA Terminal input
8. Rotary Dial
9. Min/Max button
10. Hold button
11. Accessory bay (on back, not shown)
4
2
1
3
5
6
7
8
9
10
Maximum voltage between
any terminal and earth ground
600 V Cat III Rated
Temperature Operating: -10°C to 50°C (14°F to 122°F)
Current measurements: -10°C to 40°C (14°F to 104°F)
Storage: -40°C to 60 °C (-40°F to 140°F)
Temperature Coef cient 0.1 x (speci ed accuracy)/°C (<18°C or >28°C)
Operating Altitude 2,000 meters
IP Rating (International Dust
& Water Protection)
IP54
Drop Test 1 Meter
Battery 2 AA, NEDA 15 A,IEC LR6
Battery Life Approx. 26 Hours all lights on
Fuse 600V AC/DC, 10A Fast-acting (Milwaukee p/n 22-89-0305)
Safety Compliances EN61010-1, UL 61010-1, UL 61010-031 (Probes), EN61010-031
(Probes), IEC/EN 61010-1 2nd Edition for measurement
Category III, 600 V, Pollution Degree 2, EMC EN61326-1
Certi cations cULus, CE
Symbology
Read Operator’s Manual
Double insulation
Risk of electric shock
Earth
Danger, Warning, or Caution - Consult the operators manual for additional safety
information.
Battery compartment
European Conformity Mark
Underwriters Laboratories, Inc.,
United States and Canada
Cat III Classi cation of transient overvoltages, based on nominal
line voltage to earth.
Fuse
Do not dispose of this product as unsorted municipal waste.


Product specificaties

Merk: Milwaukee
Categorie: Multimeter
Model: 2217-20

Heb je hulp nodig?

Als je hulp nodig hebt met Milwaukee 2217-20 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Multimeter Milwaukee

Handleiding Multimeter

Nieuwste handleidingen voor Multimeter