User’s Guide
CPSMC0200-2x0
Dual-Slot PointSystem™
Chassis
The Transition Networks CPSMC0200-
2x0 series dual-slot PointSystem™
chassis is designed for installation of
one or two selectable Transition
Networks mediaPointSystem™
converter slide-in modules.
Installation . . . . . . . . . . . . . . . . . . . . .2
Technical Specifications . . . . . . . . . . .4
Troubleshooting . . . . . . . . . . . . . . . .5
Compliance Information . . . . . . . . . .6
Contact Us . . . . . . . . . . . . . . . . . . . .7
Part Number Description
CPSMC0200-200 Dual-Slot PointSystem™ chassis intended for installation of any
PointSystem™ media converter slide-in modules.
CPSMC0200-210 Dual-Slot PointSystem™ chassis intended for installation of any
PointSystem™ media converter slide-in modules. Also provides
a Last Gasp trap generation.
Optional Accessories (sold separately)
Part Number Description
SPS-1872-SA Optional External Power Supply; 18-72VDC Stand-Alone
Output: 12.6VDC, 1.0 A
WMBP Optional Wall Mount Bracket; Length: 5.0 in. (127 mm)
WMBV Optional Vertical Mount Bracket; 5.0 in. (127 mm)
WMBD Optional DIN Rail Mount Bracket; 5.0 in. (127 mm)
224-hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600
CPSMC0200-200 / CPSMC0200-210
Installation
Installing a slide-in module
CAUTION: Do NOT install Two (2) PointSystem™ media converter slide-in
modules whose total power requirements exceed 12 W (with a maximum of 6 W per
slot). Failure to observe this caution could cause data transfer to fail and also could
result in damage to, and subsequent failure of, the media converter slide-in module.
CAUTION: Wear a grounding device and observe electrostatic discharge
precautions when installing the media converter slide-in module in to the dual-slot
chassis. Failure to observe this caution could result in damage to, and subsequent
failure of, the media converter slide-in module.
NOTE: If only one slide-in module is to be installed into the dual-slot chassis,
ensure network standards compliance by obtaining a custom faceplate
(P/N CPSFP-200) from Transition Networks for installation into the
second, unused slot.
To install a slide-in module into the dual-slot chassis:
1. Refer to the user’s guide that comes with the slide-in module to ensure that any
switches or jumpers on the slide-in module circuit board are set correctly for
the site installation.
2. Carefully align the slide-in module with the chassis installation guides and
slide the module into the installation slot.
3. Ensure that the slide-in module is firmly seated inside the chassis.
4. Push in and rotate the attached panel faster screw clockwise to secure the slide-
in module to the chassis front.
5. Repeat steps 1-4 for the second slide-in module.
Panel Fastener
techsupport@transition.com “Transition Now”-- Click the link for a live Web chat. 3
Installation -- Continued
Power the Chassis
To supply AC power to the dual-slot chassis:
1. Locate an appropriate 12 volt power adapter for the installed media converter
slide-in module(s).
2. Connect the barrel connector on the power adapter to the dual-slot chassis
power port (located on the back of the chassis).
3. Connect the power adapter plug to AC power.
4. Verify that the dual-slot chassis is powered by observing the illuminated
LED(s) on the installed slide-in module(s).
To supply DC power to the dual-slot chassis:
Consult the user’s guide for the Transition Networks SPS1872-xx DC external
power supply for powering the dual-slot chassis.
Last Gasp Option (CPSMC0200-210 model only)
The CPSMC0200-210 model features the Last Gasp option, which enables the
device to send out an SNMP trap to the device in the event of a power failure;
alerting the management console that the device has failed.
424-hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600
CPSMC0200-200 / CPSMC0200-210
Installation -- Continued
Grounding the Media Converter
The dual-slot chassis comes equipped with grounding lugs located on the back
panel. They require a grounding conductor wire terminated with a two-hole,
compression-type, grounding connector. The grounding wire -- which must be a
copper conductor -- is not included with the chassis and must be provided by the
customer/installer.
The electrical conducting path from the single-slot chassis must:
• Flow via the grounding lugs to the common bonding network (CBN) for
telecom installations, or to an alternative approved grounding system (if
required) for non-telecom installations.
• Be of sufficiently low impedance to conduct fault currents likely to be imposed
on the media converter, and
• Enable proper operation of any over-current protection devices.
The conductor must be fastened to the grounding lugs with the enclosed anti-
rotation star-washers and lug-nut fasteners. The applied torque required to the
connector lug-nut fasteners is specified by the connector’s manufacturer.
To properly ground the dual-slot chassis:
1. Obtain one (1) grounding conductor (12 AWG copper wire gauge or larger)
with a two-hole, compression-type, grounding connector.
2. Attach the grounding conductor to the converter by placing the two-hole
connector onto the grounding lugs and fasten with the enclosed lock-washers /
lug-nuts at the proper torque (per
the manufacturer’s
specification).
3. Attach the opposite end of the
grounding conductor to the
common bonding network (CBN)
for telecom, or to earth ground (if
required) for non-telecom
installations.
grounding
lugs
grounding
connector
and wire
earth ground
3/4-inch
spacing
Grounding lugs
(6-32, 1/8" diam.)
12 AWG copper wi
re
(not included)
Star washer (included)
Lug nuts (included)
T
wo-hole, compression-type
grounding connector
(not included)
techsupport@transition.com -- Click the “Transition Now” link for a live Web chat. 5
Technical Specifications
For use with Transition Networks Model CPSMC0200-2x0 or equivalent.
NOTE: The CPSMC0200-2x0 dual-slot chassis is Class B compliant ONLY if Class
B-compliant media converters are installed. Installation of a Class A-
compliant media converter reduces the chassis to Class A compliance.
The maximum power delivery capacity for each chassis slot is 12 Watts with an
aggregate chassis maximum of 6 W per slot. Example: A 9-Watt media converter
would require the power of both slots. In this example, the second slot must remain
unused.
Compliance EN55022; Class A&B; CE Mark
Dimensions 5.4 x 5.6 x 2.2 in (137 x 142 x 56 mm)
Weight 1.4 lb. (0.6 kg.) (approximate)
MTBF (CPSMC0200-200) Greater than 67,900 hours (MIL-HDBK-217F)
Greater than 186,900 hours (Bellcore7 V5.0)
with Powr Supply Greater than 50,700 hours (MIL-HDBK-217F)
Greater than 139,500 hours (Bellcore7 V5.0)
MTBF (CPSMC0200-210) Greater than 60,600 hours (MIL-HDBK-217F)
Greater than 183,200 hours (Bellcore7 V5.0)
with Powr Supply Greater than 49,900 hours (MIL-HDBK-217F)
Greater than 137,400 hours (Bellcore7 V5.0)
Power Supply 12VDC, 1.25 A; 100-240 VAC
Environment Tmra*: 0 to 60°C (32 to 140° F)
Storage Temp: -20 to 85°C
Humidity: 10 to 90%, non condensing
Warranty Lifetime
*Manufacturer’s rated ambient temperature for the dual-slot chassis. Refer to the
user’s guide of the installed media converter for its operating temperature range.
The information in this user’s guide is subject to change. For the most up-to-date
information on the CPSMC0100-20x dual-slot chassis, view the user’s guide on-line
at: www.transition.com.


Product specificaties

Merk: Milan
Categorie: Niet gecategoriseerd
Model: CPSMC0200-210

Heb je hulp nodig?

Als je hulp nodig hebt met Milan CPSMC0200-210 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Niet gecategoriseerd Milan

Handleiding Niet gecategoriseerd

Nieuwste handleidingen voor Niet gecategoriseerd