Midea M2605 Handleiding


Lees hieronder de 📖 handleiding in het Nederlandse voor Midea M2605 (36 pagina's) in de categorie Ketel & boiler. Deze handleiding was nuttig voor 3 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/36
AUSTRALIA AND NEW ZEALAND
GAS SAFET Y CERTIFICATION
®
DO NOT REMOVE
WaterMark
GMK10177 WM-022451
Installation And Operation Guide
FO XTE AL LLAT ON ONLR E RN INSTA I Y
Thank you very much for purchasing our
water heater. Before installing and operating
your water heater, please read this manual
carefully and keep it for future reference.
MODELS:
M2005
M2005-50
M2605
M2605-50
E5521
1
CONTENTS
PAGE
1. IMPORTANT NOTES .........................................................................................................................2
1.1. INSTALLATION NOTES ........................................................................................................2
1.2. SERVICE NOTES .................................................................................................................2
1.3. PLUMBING NOTES ..............................................................................................................2
2. SPECIFICATION ................................................................................................................................4
3. INTRODUCTION ................................................................................................................................5
3.1. DIMENSIONS AND CONNECTION POINTS (M20) .............................................................6
3.2. DIMENSIONS AND CONNECTION POINTS (M2605) .........................................................7
3.3. SAFETY GUIDELINES..........................................................................................................8
3.4. GENERAL GUIDELINES.......................................................................................................8
4. INSTALLATION ..................................................................................................................................9
4.1. CONFIRM THE APPLIANCE SUITABILITY .........................................................................9
4.2. SELECTING A SUITABLE LOCATION FOR INSTALLATION ...............................................10
4.3. CLEARANCES FOR OUTDOOR HEATER LOCATIONS ....................................................11
4.4. GAS CONNECTION..............................................................................................................12
4.5. SIZING AND CONNECTION SUITABILITY ..........................................................................12
4.6. MEASURING INLET GAS PRESSURE AND TESTING GAS LEAKAGE.............................13
4.7. WATER CONNECTIONS ......................................................................................................14
4.8. ELECTRICAL CONNECTIONS.............................................................................................14
5. REMOTE CONTROLLER ..................................................................................................................15
5.1. REMOTE CONTROLLER INSTALLATION ...........................................................................16
5.2. CONNECTION OF REMOTE CONTROLLER WIRING TO THE WATER HEATER.............17
6. INITIAL OPERATION .........................................................................................................................18
7. NORMAL OPERATION......................................................................................................................19
7.1. NORMAL OPERATION WITHOUT REMOTE CONTROLLER..............................................19
7.2. NORMAL OPERATION WITH MULTIPLE REMOTE CONTROLLERS INSTALLED ............19
7.3. FREEZE PREVENTION........................................................................................................19
8. MAINTENANCE AND SERVICE........................................................................................................21
8.1. UNIT DRAINING AND FILTER CLEANING...........................................................................21
8.2. GENERAL TROUBLESHOOTING ........................................................................................22
8.3. PCB ERROR CODES ...........................................................................................................24
8.4. WIRING DIAGRAM ...............................................................................................................26
8.5. SIDE DIVERTER...................................................................................................................27
8.6. WATER FLOW AND WATER TEMPERATURE (M20) ..........................................................30
8.7. WATER FLOW AND WATER TEMPERATURE (M2605) ......................................................30
9. M-SMART LIFE APP..........................................................................................................................31
9.1. INSTALLATION OF WI-FI MODULE (WITHOUT REMOTE CONTROLLER) .......................32
9.2.
INSTALLATION OF WI-FI MODULE (WITH REMOTE CONTROLLER)
........................................32
9.3. USING YOUR APPLIANCE WITH THE M-SMART LIFE APP..............................................34
2
WARNING
1.1 INSTALLATION NOTES
1.2 SERVICE NOTES
1.3 PLUMBING NOTES
The installation must be done in accordance with the information supplied in this manual. All other
relevant national, state and local regulations must also be adhered to including (but are not limited to):
Australian Standard AS3500.1 – Water Services.
Australian Standard AS3500.4 – Heated Water Services.
Australian Standard AS3000 – Electrical Installation.
Australian Standard AS/NZS5601 – Gas Appliance Installation.
Local Water, Gas & Electrical Authority Regulations.
Municipal Building Codes including local OH&S requirements.
Water pipe size is nominal 15mm from hot water outlet to the first tap / outlet.
Gas pipe size is nominal 20mm.
!
When connecting the hot water supply to the fixtures of the property a minimum of two (2) metres
of pipework must be used between the outlet of the water heater and the first tap / outlet.
(See Diagram on following page).
The hot water line should be insulated with Armaflex or similar pipe insulation.
When the installation is completed the temperature is to be tested at the taps to confirm the
water temperature does not exceed the required 50 setting.
1. IMPORTANT NOTES
This manual has been prepared for the relevant licensed professionals of the equipment.
Please keep it in a safe place for future reference.
Maintenance and fault-finding must be done in accordance with these instructions and the
applicable regulations listed above.
PLEASE NOTE M2005-50 and M2605-50 model is supplied factory pre-set at Nominal 50°C maximum
outlet water temperature(dip switch preset temperature as 48°C ) to comply with the requirements of
AS 3498 Clause 7.2.1.
The M2005-50 and M2605-50 unit DOES NOT REQUIRE a temperature control device to be installed.
Please follow all the instructions in the Installation Guide and the following additional instructions for
the water heater outlet connection.
Installation and service must be performed by a licensed professional (for example, a
licensed plumber or gas fitter).
The outlet intended to deliver heated water to sanitary fixtures used primarily for personal
hygiene purposes.
PLEASE NOTE M2005 and M2605 models are Nominal 70°C maximum outlet water
temperature to comply with the requirements of AS 3498 Clause 7.2.2
The M2005 and M2605 unit REQUIRES a temperature control device to be installed.
The M2005 and M2605 unit preset temperature is 55°C.


Product specificaties

Merk: Midea
Categorie: Ketel & boiler
Model: M2605

Heb je hulp nodig?

Als je hulp nodig hebt met Midea M2605 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Ketel & boiler Midea

Handleiding Ketel & boiler

Nieuwste handleidingen voor Ketel & boiler