Midea D15-15VDO Handleiding

Midea Ketel & boiler D15-15VDO

Lees hieronder de πŸ“– handleiding in het Nederlandse voor Midea D15-15VDO (32 pagina's) in de categorie Ketel & boiler. Deze handleiding was nuttig voor 34 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/32
Storage Electric Water Heater
The diagram above is just for reference. Please take the
appearance of the actual product as the standard.
Instruction Manual
Congratulations! You are now a proud owner of Midea water heater. We assure you that this
product conforms to the highest standards of quality. Before installing and operating your water
heater, please read this manual carefully and keep it for future reference.
For Model: D10-15VDO
D10-15VDU
D15-15VDO
D15-15VDU
D30-15VDO
D30-15VDU
1
The installation and maintenance has to be carried out by qualified professionals or Midea
authorized technicians.
The manufacturer shall not be held responsible for any damage or malfunction caused by wrong
installation or failing to comply with following instructions included in this pamphlet.
For more detailed installation and maintenance guidelines, please refer to below chapters.
TABLE OF CONTENTS
TITLE PAGE
1.Cautions ...........................................................................................................................(2)
2.Product introduction .........................................................................................................(3)
3.Unit installation .................................................................................................................(5)
4.Methods of using ..............................................................................................................(7)
5.Maintenance.....................................................................................................................(8)
6.Troubleshooting................................................................................................................(9)
7.PRODUCE INFORMATION WITH EU REGULATION ...................................................(10)
●
●
●
General Remark
2
Before installing this water heater,check and confirm that the earthing on the supply socket is
reliably grounded. Otherwise, the electrical water heater can not be installed and used. Do not use
extension boards. Incorrect installation and use of this electrical water heater may result in serious
injuries and loss of property.
Special Cautions
1. CAUTIONS
The water heater is not intended for use by persons (including children) with reduced physical,
sensory or mental capabilities, or lack of experience and knowledge, unless they have been given
supervision or instructions concerning use of the appliance by a person responsible for their safety.
Children should be supervised to ensure that they do not play with the heater.
The wall in which the electrical water heater is installed must be able to bear the load more than
two times of the heater filled fully with water without distortion and cracks. Otherwise, other
strengthening measures must be adopted.
The supply socket must be earthed reliably. The installation height of the supply socket must not
be lower than 1.8m. The rated current of the socket must not be lower than 16A. The socket and
plug must be kept dry to prevent electrical leakage. If the flexible power supply cord is damaged, the
special supply cord provided by the manufacturer must be selected, and replaced by the professional
maintenance personnel.
The maximum inlet water pressure is 0.5MPa; the minimum inlet water pressure is 0.1MPa, if this
is necessary for the correct operation of the appliance.
When using the heater for the first time (or the first use after maintenance), the heater can not be
switched on until it has been filled fully with water. When filling the water, at least one of the outlet
valves at the outlet of the heater must be opened to exhaust the air. This valve can be closed after
the heater has been filled fully with water.
The pressure relief valve attached with the heater must be installed at the cold water inlet of this
heater, and make sure it is not exposed in the foggy. The water may be outflowed from pressure
relief valve, so the outflow pipe must open wide in the air. In order to drain away the water inside
the inner container, it can be drained away from the pressure release valve. Twist the thread screw
of the pressure release valve off, and lift the drain handle upwards(See Fig.1) . The drainage pipe
connected to the pressure release hole must be kept sloping downwards and in a frost-free
environment. The water may drip from the discharge pipe of the pressure-relief device and that this
pipe must be left open to the atmosphere.
During heating, there may be drops of water dripping from the pressure release hole of the
pressure relief valve, this is a normal phenomenon. The pressure release hole shall not be blocked
under no circumstances, otherwise, the heater may get damaged, even resulting in accidents. If
there is a large amount of water leak, please contact customer care center for repair.
The pressure relief valve need to be checked and cleaned regularly, so as to make sure it will not
be blocked.
Since the water temperature inside the heater can reach up to 75 , the hot water must not be ℃
exposed to human bodies when it is initially used. Adjust the water temperature to a suitable
temperature to avoid scalding.
If any parts and components of this electrical water heater are damaged please contact customer
care center for repair.


Product specificaties

Merk: Midea
Categorie: Ketel & boiler
Model: D15-15VDO

Heb je hulp nodig?

Als je hulp nodig hebt met Midea D15-15VDO stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Ketel & boiler Midea

Handleiding Ketel & boiler

Nieuwste handleidingen voor Ketel & boiler