MBS ASK 31.3 Handleiding
MBS
Multimeter
ASK 31.3
Lees hieronder de 📖 handleiding in het Nederlandse voor MBS ASK 31.3 (18 pagina's) in de categorie Multimeter. Deze handleiding was nuttig voor 42 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld
Pagina 1/18
Operating instructions /
Installation instructions
Please keep!
Low-voltage current transformer
- Plug-in current transformers -
ASK, SASK series
MBS AG
Eisbachstrasse 51
74429 Sulzbach-Laufen
Tel. +49 7976 9851-0
Fax. +49 7976 9851- 90
info@mbs-ag.com www.mbs-ag.com •
Before installation, commissioning or operation
of the device, read these instructions carefully
and thoroughly.
1. Safety instructions
CAUTION
The following points must be noted:
ï‚· ï€ The applicable laws, standards and provisions.
ï‚· ï€ The state of the technological art at the time of installation.
ï‚· ï€ The rules surrounding technology.
ï‚· ï€ The operating instructions.
ï‚· The fact that operating instructions can only include general
instructions and that these instructions must be observed.ï€
ï‚· Before commissioning, check the device carefully for any damage
it may have sustained during transport. In the event of mechanical
damage, the device must not be put into operation.ï€
 The devices described are designed for installation by qualied
specialist electricians and must only be installed in electrical plant
rooms or in closed housings. Any other use or failure to comply with
these usage instructions will render the warranty / guarantee null
and void.ï€
ï‚· ï€ Devices must only be installed in dry, indoor spaces.
ï‚· ï€ Do not install on easily ammable materials.
ï‚· Operation with a rated current higher than that stated on the type
plate can result in overheating of the current transformer and burns.ï€
2. Functional description
Current transformers in the ASK and SASK series are inductive
single-wire current transformers that operate on the transformer
principle. They are used to adapt the primary measuring parameter to
the input rated parameters of the connected measuring equipment.
As a result of the measuring principle used, these current transformers
are only suitable for use on alternating current networks.
Current transformers of the ASK and SASK series are
maintenance-free.
3. Warning information
WARNING
Dangerous electrical voltage can cause electric shock and burns.
Ensure that the information on the type plate and in the "Technical data"
under Point 5 matches the operating parameters of the system.
Before starting any installation work, disconnect the system from the
power supply!
WARNING
If there is an unladen (open) secondary circuit in the current
transformer, high voltages will be induced at its secondary
terminals. The voltage values that occur there represent a danger
to persons and to the functional safety of the current transformer.
"Open mode", i.e. operation of the current transformer
without secondary circuitry, must be avoided at all costs.
Product specificaties
Merk: | MBS |
Categorie: | Multimeter |
Model: | ASK 31.3 |
Heb je hulp nodig?
Als je hulp nodig hebt met MBS ASK 31.3 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding Multimeter MBS
2 Juli 2023
20 Juni 2023
18 Juni 2023
Handleiding Multimeter
- Multimeter Abus
- Multimeter Aldi
- Multimeter Alecto
- Multimeter Altai
- Multimeter Amiko
- Multimeter Amprobe
- Multimeter Appa
- Multimeter Basetech
- Multimeter Beha-Amprobe
- Multimeter Benning
- Multimeter Brandson
- Multimeter Brennenstuhl
- Multimeter Bruder Mannesmann
- Multimeter Digitus
- Multimeter Elma
- Multimeter Elro
- Multimeter Extech
- Multimeter Ferm
- Multimeter Flir
- Multimeter Fluke
- Multimeter Gembird
- Multimeter Gossen Metrawatt
- Multimeter Greenlee
- Multimeter Hager
- Multimeter Hubinont
- Multimeter Ideal
- Multimeter Keithley
- Multimeter Kingcraft
- Multimeter Laserliner
- Multimeter Mastech
- Multimeter Maxwell
- Multimeter Megger
- Multimeter Metrel
- Multimeter Metrix
- Multimeter Micronta
- Multimeter Milwaukee
- Multimeter Monacor
- Multimeter Parkside
- Multimeter PCE Instruments
- Multimeter Perel
- Multimeter Plieger
- Multimeter Powerfix
- Multimeter Profile
- Multimeter Sanwa
- Multimeter Schneider
- Multimeter Silverline
- Multimeter Skandia
- Multimeter Stanley
- Multimeter TFA
- Multimeter Topcraft
- Multimeter Uni-T
- Multimeter Velleman
- Multimeter Voltcraft
- Multimeter Wiha
- Multimeter Workzone
- Multimeter Joy-it
- Multimeter Jung
- Multimeter Clas Ohlson
- Multimeter Steren
- Multimeter Klein Tools
- Multimeter EMOS
- Multimeter Tacklife
- Multimeter Biltema
- Multimeter REV
- Multimeter Etekcity
- Multimeter Testo
- Multimeter Somogyi
- Multimeter Testboy
- Multimeter Yato
- Multimeter Wago
- Multimeter GW Instek
- Multimeter Kyoritsu
- Multimeter Owon
- Multimeter Projecta
- Multimeter Cablexpert
- Multimeter Högert
- Multimeter Multimetrix
- Multimeter Digi-tool
- Multimeter Kewtech
- Multimeter Sonel
- Multimeter Testec
- Multimeter Vimar
- Multimeter Strex
- Multimeter PeakTech
- Multimeter MGL Avionics
- Multimeter Rigol
- Multimeter Chauvin Arnoux
- Multimeter Aim TTi
- Multimeter CEM
- Multimeter Horex
- Multimeter Cosinus
- Multimeter Kurth Electronic
- Multimeter IWH
- Multimeter Weltron
- Multimeter Rohde & Schwarz
- Multimeter EEVBlog
- Multimeter Weidmüller
- Multimeter HT Instruments
- Multimeter Caltek
- Multimeter Elworks
- Multimeter Qian
- Multimeter Bearware
- Multimeter Noyafa
Nieuwste handleidingen voor Multimeter
21 December 2024
16 December 2024
7 December 2024
7 December 2024
5 December 2024
5 December 2024
3 December 2024
2 December 2024
1 December 2024
1 December 2024