Martin Jem Heavy Fog Glaciator Handleiding

Martin Niet gecategoriseerd Jem Heavy Fog Glaciator

Lees hieronder de 📖 handleiding in het Nederlandse voor Martin Jem Heavy Fog Glaciator (10 pagina's) in de categorie Niet gecategoriseerd. Deze handleiding was nuttig voor 51 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/10
Martin Professional A/S,Olof Palmes Allé 18, DK-8200,Aarhus N
Phone: +45 87 40 00 00 Internet: www.martin.dk
Heavy Fog
Glaciator
USER GUIDE
VERSION 1.1
NOTE! The JEM warranty will be void if any fluid other than JEM
approved fluid is used. If other fluids are used there could be serious
damage to the machine and the fluid may not have been tested for use
in public areas.
Fluids Suitable for this system:
Heavy Fog
Fluid B2
Heavy Fog
Fluid C3
HEAVY FOG GLACIATOR
CONNECTIONS
HEAVY FOG GLACIATOR
17
REMOTE
INTERFACE
1-GND, 2-12V OUT, 3-INPUT
1 FOG
2 STANDBY
3 TIMER
4 FAN
5 SPECIAL
6 GND
DMX ADDRESS
1
2
4
8
16
32
64
128
256
SPECIAL 1
SPECIAL 2
SPECIAL 3
ON 1
2
3
4
5
6
7
8
9
10
11
12
DMX DATA
INPUT
INOUT
1
5
6
9
1 GND
2 COLD
3 HOT
FUSE RATINGS
The Heavy Fog Glaciator uses
four fuses.
They should be replaced with
the value and type detailed
below:
DMX receiver low voltage
2AT
Power PCB
12AT
Compressor control relay
12AT
Main input fuse
20AT
Three of these fuses are
located internally and should
not be accessed without first
disconnecting the power supply.
FILTERS
The Heavy Fog Glaciator uses
a washable synthetic fibre filter
in the air intake for the
condenser unit (located at the
top of the machine). This can
be removed for cleaning by
removing the ventilation grill
above it (two M5 screws). Use
the following guidelines for
when to check the filter.
:
Inspect and clean/replace every
250 hours
:
Inspect and clean/replace every
150 hours
Normal Conditions
Severe Conditions
SPECIFICATION
HEAT EXCHANGER
2.5KW heater (240V)
Wide bore steel vaporizing coil
Ceramic thermal trip for over-temperature protection
Electronic Temperature control using thermocouple
FLUID SYSTEM
Oscillating piston high pressure fluid pump
Low fluid detection by electronic sensor
9.5L fluid containers (2.5 US Gal.)
DMX512 decoder:
Required Channels = 2
Output is proportional for all levels above 12%
Channels supported = 1 to 511
Valid start codes = 0 (dimmer data only)
Full framing error detection implemented
Analogue control via standard JEM Multifunction Contoller.
Optional PLC interface for simple switching control of the system.
CONTROL PANEL
2 x LED displays with 4 button keypad
Output level control from 0 to 100% for Fog
Timer range:
Delay time (toF) 0 seconds - 90 seconds
Run time (ton) 0 seconds - 90 seconds
REFRIGERATION UNIT
2/3 HP compressor with thermostatic control
Uses refrigerant R404A (0.850 Kg)
OUTPUT CONNECTION
Ducting adaptor to accept 150mm (6”) flexible ducting
POWER REQUIREMENTS
Input voltage 200 - 250vac
Input power (max) 3.1Kw
Main fuse 20AT
Frequency 50/60Hz dependant on model.
Maximum fluid consumption 120mL/minute
REMOTE CONTROL OPTIONS
HEAVY FOG GLACIATOR
USER
GUIDE
16
HEAVY FOG GLACIATOR
USER
GUIDE
USER GUIDE CONTENTS
Introduction 2
Features 2
Safety Guidelines 3
Machine Layout 4
Commissioning The Machine 5
Remote Control Options 5
DMX Operation 6
The Display 8
Control Panel Functions 10
The Timer 11
Basic Operation 12
The Fluid System 13
Display Messages 14
Basic Fault Finding 15
Specification 16
Connections 17
Fuse Ratings 17
Filter Maintenance 17
1
© Martin Professional A/S, Denmark.2000
All rights reserved. No part of this manual may be reproduced, in any form or
by any means, without permission in writing from Martin Professional A/S,
Denmark.


Product specificaties

Merk: Martin
Categorie: Niet gecategoriseerd
Model: Jem Heavy Fog Glaciator

Heb je hulp nodig?

Als je hulp nodig hebt met Martin Jem Heavy Fog Glaciator stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Niet gecategoriseerd Martin

Handleiding Niet gecategoriseerd

Nieuwste handleidingen voor Niet gecategoriseerd