Model Ice Machines Drain Pump SM
Installation Instructions
1. Disconnect power.
2. Remove two top cover screws and slide cover o๎€.
3. Remove eight back panel screws and lift panel o๎€.
4. Loosen the coupling panel and water inlet line clamp.
5. Remove bin drain tube and clamp.
6. Replace existing drain ๎‹‡tting with new part.
7. Place two pieces of tape on the bottom of the drain pump.
8. Preassemble tubes on drain pump.
a. Pump Outlet Tube (13.50โ€)
b. Vent Tube (26.0 โ€)
c. Bin Drain Tube
9. The drain pump plugs into and is wired to the ice machine. Cut the cable tie that is holding the wires together. Connect
wires, #41 and #42, to the drain pump and connect the plugs. -secure the wires with a cable tie. Re
10. Slide the drain pump into the machine; make sure the wires are routed up over the pump. Keep the wires away from the fan.
11. Attach the bin drain tube to the bin drain opening (where the original bin drain tube was installed.)
12. Route the vent tube up along the suction line. Secure the vent tube to the suction line with two cable ties.
13. Route the pump outlet tube behind the bin drain tube and out the coupling panel. Make sure there are no kinks in the tubing.
14. Use supplied spring clamps to secure tubing to all three drain pump outlets .
15. Connect power and manually ๎‹‡ll bin with water until drain pump activates. Check tubing connections for leaks.
16. Reinstall panels and top cover.
NOTE: Drain hose requirements - Maximum Rise = 12 feet, Maximum Run = 100 feet
Manitowoc Ice
2110 South 26 th
Street, P.O. Box 1720, Manitowoc, WI 54221-1720 USA
Telephone 920- -0161, Fax - Sales: 920- -7589, Service/Parts: - -7585, Other: 920- -7879 000313 682 683 920 683 683 000
Web Site - www.manitowocice.com 08/24/09
Bin Drain
Tube
Condensate
Pump Water
Outlet
Vent Tube
Condensate
Pump
Bin
Drain
Tube
Dra Fitting in
(See #6 above)
Coupling Panel
Screws
Back
Panel
Screws
Top Cover Screws


Product specificaties

Merk: Manitowoc
Categorie: Niet gecategoriseerd
Model: UCP0050A

Heb je hulp nodig?

Als je hulp nodig hebt met Manitowoc UCP0050A stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Niet gecategoriseerd Manitowoc

Handleiding Niet gecategoriseerd

Nieuwste handleidingen voor Niet gecategoriseerd

Smeg

Smeg GTA-6 Handleiding

21 November 2024
Smeg

Smeg KIT6CX Handleiding

21 November 2024
Senal

Senal SCS-98 Handleiding

21 November 2024
Senal

Senal ASM-6 Handleiding

21 November 2024
Senal

Senal ASM-MNTKIT Handleiding

21 November 2024
Senal

Senal SMS-45 Handleiding

21 November 2024
Smeg

Smeg KIT6PX Handleiding

21 November 2024
Senal

Senal SCI-3212MP Handleiding

21 November 2024
Senal

Senal OLM-2S-P Handleiding

21 November 2024