Safety data sheet according to Regulation (EC) No 1907/2006, Annex II
Revision: 05.05.2010 Replaces the version of: 05.05.2010 PDF date: 19.05.2010
Fuel Cell 18g, 25g, 40g
Safety data sheet
according to Regulation (EC) No 1907/2006, Annex II
1. IDENTIFICATION OF THE SUBSTANCE/PREPARATION AND OF THE
COMPANY/UNDERTAKING
Identification of the substance or preparation
Fuel Cell 18g, 25g, 40g
Use of the substance/preparation
--
Company/undertaking identification
OK Befestigung GmbH & Co. KG, Liesentorweg 19 A, D-47802 Krefeld
Telephone +49 (0)2151 953639, Fax +49 (0)2151 953649
www.okbefestigung.de
E-mail address of the competent person:
--
Emergency telephone
Advisory office in case of poisoning:
Tel.:
---
Telephone number of the company in case of emergencies:
Tel. +49 (0)2151 953639
2. HAZARDS IDENTIFICATION
Preparation is classified as hazardous in the sense of directive 1999/45/EC.
To people
See point 11 and 15.
Product is extremely flammable.
When using: development of explosive vapour/air mixture possible.
Danger of bursting (explosion) when heated
Liquid projections or spray may cause frostbite.
To the environment
See point 12.
Not applicable
3. COMPOSITION/INFORMATION ON INGREDIENTS
Gen. description:
Lubricant
Chemical name
content % Symbol Chemical name EINECS, ELINCS
Registration number
(ECHA)
Classification categories / Indications of
danger:
Propane
10 - 30 F+ 12 200-827-9
Extremely flammable
Chemical name
content % Symbol Chemical name EINECS, ELINCS
Registration number
(ECHA)
Classification categories / Indications of
danger:
Butane
60 - 80 F+ 12 203-448-7
Extremely flammable
Chemical name
content % Symbol Chemical name EINECS, ELINCS
1 / 6
Safety data sheet according to Regulation (EC) No 1907/2006, Annex II
Revision: 05.05.2010 Replaces the version of: 05.05.2010 PDF date: 19.05.2010
Fuel Cell 18g, 25g, 40g
Registration number
(ECHA)
Classification categories / Indications of
danger:
Nitrogen
--- --- 231-783-9
For complete wording of the R-phrases / H-phrases (GHS/CLP), refer to point 16.
4. FIRST AID MEASURES
4.1 Inhalation
Keep Data Sheet available.
Supply person with fresh air. Call doctor immediately.
4.2 Skin contact
Cover frostbite aseptically.
No attempt should be made to remove the product from the skin.
Carefully and gently brush the contaminated body surfaces in order to remove all traces of product.
Wash off with cold water.
Never use warm water.
Consult doctor immediately - keep Data Sheet available.
4.2 Eye contact
Wash thoroughly for several minutes using copious water. Seek medical help if necessary.
5. FIRE-FIGHTING MEASURES
5.1 Suitable extinguishing media
Dry extinguisher
CO2
Water jet spray
Foam
Cool container at risk with water.
5.2 Extinguishing media which shall not be used for safety reasons
High volume water jet
5.3 Special exposure hazards arising from the substance or preparation itself,
combustion products, resulting gases
In case of fire the following can develop:
Danger of explosion by prolonged heating.
Explosive vapour/air mixture
Oxides of carbon
Hydrocarbons
Extinguishing water must not be poured down the drain.
Danger of explosion
5.4 Special protective equipment for fire-fighters
Protective respirator with independent air supply.
Full protection, if necessary
5.5 Further information
Dispose of contaminated extinction water according to official regulations.
6. ACCIDENTAL RELEASE MEASURES
Refer to point 13. and for personal protection refer to point 8.
6.1 Personal precautions
Remove possible causes of ignition - do not smoke.
Ensure sufficient supply of air.
Avoid inhaling
6.2 Environmental precautions
If leakage occurs, dam up.
Prevent from entering drainage system.
Prevent penetration into drains, cellars, working pits or other places in which accumulation could be hazardous.
Danger of explosion
6.3 Methods for cleaning up
If spray or gas escapes, ensure ample fresh air is available.
Allow to evaporate.
Respirator with filter
2 / 6
Safety data sheet according to Regulation (EC) No 1907/2006, Annex II
Revision: 05.05.2010 Replaces the version of: 05.05.2010 PDF date: 19.05.2010
Fuel Cell 18g, 25g, 40g
7. HANDLING AND STORAGE
7.1 Handling
Tips for safe handling:
See point 6.1
Observe directions on label and instructions for use.
Keep away from sources of ignition - Do not smoke.
Ensure good ventilation.
Use working methods according to operating instructions.
Take precautions against electrostatic charges.
Vapours heavier than air.
Without adequate ventilation, formation of explosive mixtures may be possible.
7.2. Storage
Requirements for storage rooms and
containers:
Not to be stored in gangways or stair wells.
Do not store with flammable or self-igniting materials.
Observe regulations for keeping separated.
Store product closed and only in original packing.
Observe special regulations for aerosols!
Special storage conditions:
See point 10
Keep protected from direct sunlight and temperatures over 50°C.
Only store at temperatures from 10°C to 25°C
Pressure increase will result in danger of bursting.
8. EXPOSURE CONTROLS/PERSONAL PROTECTION
8.1 Exposure limit values
Chemical Name Propane Content %:10 -
30
WEL-TWA: 1000 ppm (ACGIH) WEL-STEL: --- ---
BMGV: --- Other information: ---
Chemical Name Butane Content %:60 -
80
WEL-TWA: 600 ppm (1450 mg/m3) WEL-STEL: 750 ppm (1810 mg/m3) ---
BMGV: --- Other information: ---
WEL-TWA = Workplace Exposure Limit - Long-term exposure limit (8-hour TWA (= time weighted average) reference period)
EH40. AGW = "Arbeitsplatzgrenzwert" (workplace limit value, Germany). | WEL-STEL = Workplace Exposure Limit - Short-terme
exposure limit (15-minute reference period). | BMGV = Biological monitoring guidance value EH40. BGW = "Biologischer Grenzwert"
(biological limit value, Germany) | Other information: Sen = Capable of causing occupational asthma. Sk = Can be absorbed through
skin. Carc = Capable of causing cancer and/or heritable genetic damage.
** = The exposure limit for this substance is repealed through the TRGS 900 (Germany) of January 2006 with the goal of revision.
8.2 Exposure controls
8.2.1 Occupational exposure controls
Ensure good ventilation. This can be achieved by local suction or general air extraction.
If this is insufficient to maintain the concentration under the WEL or AGW values, suitable breathing protection should be worn.
Applies only if maximum permissible exposure values are listed here.
General hygiene measures for the handling of chemicals are applicable.
Wash hands before breaks and at end of work.
Keep away from food, drink and animal feedingstuffs.
Respiratory protection: If OES or MEL is exceeded.
Hand protection:
Eye protection: Tight fitting protective goggles (EN 166) with side protection,
with danger of projections.
Skin protection: Protective working garments (e.g. safety shoes EN ISO 20345,
long-sleeved protective working garments)
Additional information on hand protection - No tests have been performed.
Selection made for preparations according to the best available knowledge and information on the ingredients.
Selection of materials derived from glove manufacturer's indications.