LightKeeper Pro TEST-200 Handleiding


Lees hieronder de 📖 handleiding in het Nederlandse voor LightKeeper Pro TEST-200 (6 pagina's) in de categorie Niet gecategoriseerd. Deze handleiding was nuttig voor 8 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/6
2.5 Volt 170mA Bulbs
Focos 170mA de 2.5
voltios
Repara Series de Luces
Fixes Light Sets
Fast & Easy!
Batteries Included
Baterías Incluidas
The Complete Tool for Fixing Incandescent Light Sets
La Herramienta Completa para Reparar Series de Luces Incandescentes
¡Rápido Y Fácil!
NOTE: low - res images
W
h
e
n
L
i
g
h
t
s
e
t
s
a
r
e
b
e
i
n
g
r
e
p
a
i
r
e
d
,
w
o
r
d
s
o
f
t
e
n
g
e
t
u
s
e
d
t
h
a
t
a
r
e
n
'
t
i
n
a
n
y
C
h
r
i
s
t
m
a
s
C
a
r
o
l
s
.
"
V
i
s
i
t
L
i
g
h
t
K
e
e
p
e
r
P
r
o
.
c
o
m
f
o
r
g
r
e
a
t
v
i
s
u
a
l
a
s
s
i
s
t
a
n
c
e
.
"
D
u
r
a
n
t
e
l
a
r
e
p
a
r
a
c
i
ó
n
d
e
s
e
r
i
e
s
d
e
l
u
c
e
s
,
g
e
n
e
r
a
l
m
e
n
t
e
s
e
u
s
a
n
p
a
l
a
b
r
a
s
q
u
e
n
o
s
e
i
n
c
l
u
y
e
n
e
n
l
o
s
v
i
l
l
a
n
c
i
c
o
s
n
a
v
i
d
e
ñ
o
s
"
.
V
i
s
i
t
e
L
i
g
h
t
K
e
e
p
e
r
P
r
o
.
c
o
m
p
a
r
a
o
b
t
e
n
e
r
u
n
a
e
x
c
e
l
e
n
t
e
a
y
u
d
a
v
i
s
u
a
l
.
7.5”
Things You Will Need to Know:
Numerous blackened bulbs are indicative of a light set that is
at the end of its useful life.
• The Voltage Detector is calibrated to work on a non-working
light set and is intended to be used on a working set.not
• When activating Voltage Detector (Top Black Button) a “Chirp”
may be heard which indicates that it’s working properly. Not
to be confused with “Continuous Beeping” which means there
is 120 Volts present.
• Blown fuses are rarely the cause of the light set failure.
Blown fuses are the result of an overloaded circuit or by
connecting too many light sets together end to end.
• Both bulb wires must make a complete connection with metal
contacts in the socket.
• 50 good bulbs placed in 49 good sockets & 1 bad socket
results in a failed light set. Inspect bulb socket contacts for
proper alignment. Both should be up to an equal height.
• While using the Voltage Detector, do not hold the bulb
socket in your hand (keep your hand at least 6” away). Your
body acts as a ground and will alter the results.
• Some light sets are produced with one non-replaceable fused
bulb. This bulb will have a different color ring at the base of
the socket. If this bulb burns out, the set is not repairable.
1
Quick Fix Trigger – Socket Connector
Fix Lights using the Quick Fix Trigger Technology which
repairs the most common problem of light set failure, a
malfunctioning bulb “shunt”.
Step 1A: Locate and remove any single from the light Unlit Bulb
set section that is not lit. Clear the socket area of tinsel or any
foreign material.
Plug the empty bulb socket fully into the LightKeeper Pros®
Socket Connector. The metal contacts of the bulb socket
must line up with the metal contacts of the LightKeeper
Pros® Socket Connector (Fig. A).
Step 1B: With the bulb socket in the Socket Connector and the
light set plugged into the AC outlet, pull the trigger until the
light set illuminates. If lights do not illuminate after 30 pulls
then use the Voltage Detector in Step 2A.
Step 1C: Unplug the light set from the AC outlet and return
the removed bulb to the empty light socket. Be sure to replace
any unlit bulbs to help extend the life of your light set.
IF THE SOCKET DOES NOT FIT INTO SOCKET CONNECTOR, THEN SEE
ALTERNATE QUICK FIX METHOD. PLEASE REFERENCE PAGE 3.
Lo Que Necesitará Saber:
• Una gran cantidad de focos fundidos indica una serie de luces que p2-ya llegó al
final de su vida útil.
• El detector de voltaje está calibrado para funcionar en una serie de luces que
no funciona y está diseñado para utilizarse en una serie que funciona.no
• Al activar el detector de voltaje (botón negro superior) puede escucharse un
sonido breve que indica que está funcionando correctamente. No debe
confundirse con el sonido continuo que significa que hay 120 voltios presentes.
• Los fusibles fundidos rara vez son la causa de la falla de una serie de luces. Los
fusibles fundidos son el resultado de un circuito sobrecargado o de la conexión
de demasiadas series de luces entre sí.
• Los dos alambres del foco deben hacer una conexión total con los contactos de
metal del portafoco.
• 50 focos en buenas condiciones colocados en 49 portafocos en buenas
condiciones y 1 portafocos en malas condiciones ocasiona que la serie de luces
falle. Inspeccione que la alineación de los contactos del portafocos sea correcta.
Los dos deben estar a una misma altura.
• Mientras utilice el detector de voltaje, no sostenga el portafocos en la mano
(mantenga la mano a una distancia mínima de 6"). Su cuerpo actuará como
tierra y se alt erarán los resultados.
• Algunas series de luces se producen con un foco con fusible no reemplazable.
Este foco tiene un anillo de color diferente en la base de la toma. Si este foco se
funde, p2-ya no es posible reparar la serie.
1
Disparador de Reparación Rápida –
Conector de Portafocos
Repare las luces usando la Tecnología de disparador de reparación rápida, la
cual repara el problema más común en las fallas de las series de luces: un
derivador de corriente eléctrica averiado en un foco.
Paso 1A: Localice y retire los focos no iluminados de la sección de la serie de
luces que no esté iluminada. Limpie el área del portafoco de la serie de luces
quitando todo oropel o materiales extraños.
Inserte completamente el portafoco vacío en el conector para portafocos del
LightKeeper Pro®. Los contactos de metal del portafoco deben alinearse con los
contactos de metal del conector para portafocos del LightKeeper Pro® (Fig. A).
Paso 1B: Con el portafoco en el conector para portafocos y la serie de luces
conectada en el tomacorriente , jale el disparador hasta que la serie de luces se
ilumine. Si las luces no se iluminan después de 30 activaciones del disparador,
utilice el detector de voltaje del paso 2A.
Paso 1C: Desconecte la serie de luces del tomacorriente y vuelva a colocar en el
portafoco vacío el foco que había retirado. Asegúrese de reemplazar todos los focos
que no se enciendan para prolongar la vida de su serie de luces.
SI EL PORTAFOCO NO SE AJUSTA EN EL CONECTOR PARA PORTAFOCOS, CONSULTE EL
MÉTODO ALTERNO DE REPARACIÓN RÁPIDA. CONSULTE LA PÁGINA 3.
See how it is done:
LightKeeperPro.com
Mire cómo se hace:
LightKeeperPro.com
1
A Cool Yule Tool
®
CAUTION: This product should not be used in the rain or in other conditions which could present a shock hazard.
PRECAUCIÓN: Este producto no debe utilizarse en la lluvia ni en otras condiciones que pudieran representar un peligro de descarga eléctrica.
a
7.5”
2
Audible Voltage Detector
This is a second technique that helps locate circuit interrup-
tions caused by loose bulbs, twisted wires and other
problems not solved by the Quick Fix Trigger method.
Step 2A: Plug the defective light set into the AC outlet. Hold
down the black button on top of the LightKeeper Pro® to activate
the Voltage Detector. The red LED will light and the detector
may “Chirp” indicating the detector is on. Place the tip of the
LightKeeper Pro® against the first bulb closest to the plug and AC
outlet (Fig. B). If a continuous beeping is heard, go to Step 2B.
If you do not hear a continuous beeping at the first bulb, reverse
the plug 180 degrees in the AC outlet.
Simply stated: continuous beeping indicates the presence of
voltage. No beeping indicates the lack of voltage.
Step 2B: Scan the of the light set starting at the first unlit section
bulb closest to the plug. Put the tip of the LightKeeper Pro®
between bulb one and two and establish a distance from the wires
where a continuous beeping can be heard (average 1/2”). Maintain-
ing this distance, scan the length of the unlit section until the
detector stops beeping (Fig. C). The bulb and socket between where
the detector beeps and does not beep is the source of a problem.
Remove and test the indicated bulb and replace if necessary. Also,
visually inspect the bulb socket contacts for proper alignment. All
lights should now illuminate. If not, continue your scan from this
point until you find what may be an additional problem.
Hints from the LightKeeper “Pros”
We’ve all heard “when one bulb burns out the rest stay lit”.
Internal bulb failure does not always support this statement.
• Practice with Voltage Detector by removing a bulb from a
working Light set. Start scanning, a continuous beeping
should be heard up to the point of interruption and no
beeping beyond it.
• Failure to replace burned out bulbs decreases the life of the
light set by adding additional stress. Four burned out bulbs
within a 50 light set decreases the life of the set by 67%.
• 2.5 volt bulbs are used in 50, 100, and 150 light sets. 3.5
volt bulbs are used in 35 and 70 light sets. Consult the tag
attached to your light set for specifications.
• Expected bulb life spans a range from 1000 to 3000 hours
of usage.
2 Detector Audible de Voltaje
El detector audible de voltaje es una segunda tecnología que ayuda a localizar
interrupciones de circuitos causadas por focos flojos, cables retorcidos y otro
tipo de problemas que no se puedan resolver con el método del disparador de
reparación rápida.
Paso 2A: Conecte en el tomacorriente la serie de luces defectuosa. Para activar el
detector de voltaje oprima el botón negro que se encuentra en la parte superior del
LightKeeper Pro®. El LED rojo se encenderá y el detector puede emitir un sonido
para indicar que está encendido. Coloque la punta del LightKeeper Pro® contra el
primer foco más cercano al enchufe y al tomacorriente (Fig. B). Si oye un sonido
continuo, prosiga con el paso 2B. Si no oye un sonido continuo en el primer foco,
invierta el enchufe 180 grados en el tomacorriente de CA.
Dicho simplemente: el sonido continuo indica la presencia de voltaje. La falta
de sonido indica la carencia de voltaje.
Paso 2B: Revise la sección no iluminada de la serie de luces, empezando con el
primer foco más cercano al enchufe. Coloque la punta del LightKeeper Pro®
entre el
foco uno y el foco dos y establezca una distancia desde los cables en los que se
oiga un sonido continuo (en promedio 1/2”). Manteniendo esta distancia, recorra
toda la sección no iluminada hasta que el detector deje de emitir sonido (Fig. C).
El foco y el portafoco que se encuentran entre el lugar donde el detector emite el
sonido y donde no lo hace es el origen del problema.
Quite y pruebe el foco indicado y reemplácelo si es necesario. Además, verifique
visualmente que los contactos del portafoco estén bien alineados. Ahora todas las
luces se deben encender. Si no se encienden, continúe recorriendo la serie desde
este punto hasta que encuentre lo que podría ser otro problema.
Sugerencias de los Profesionales de LightKeeper
Todos hemos oído que “cuando un foco se funde, el resto permanecerá encendido”.
Las fallas internas de los focos no siempre apoyan esta declaración.
• Practique con el detector de voltaje y quite un foco de una serie que funcione.
Empiece a recorrer la serie con el detector, debe escucharse un sonido continuo
hasta el punto de interrupción y no debe haber más sonido después de ese punto.
• Al no cambiar los focos fundidos se disminuye la vida útil de la serie, debido a que
se le aplica una tensión adicional. Cuatro focos fundidos en una serie de 50 luces
reduce un 67% la vida útil de la serie.
• Los focos de 2.5 voltios se usan en las series de 50, 100 y 150 luces. En los
juegos de luces de 35 y 70 focos se usan focos de 3.5 voltios. Consulte la
etiqueta de su juego de luces para ver las especificaciones.
• La vida útil esperada de un foco es entre 1000 y 3000 horas de uso.
Ope
2
A Cool Yule Tool
®
Questions?
888-858-2548
LightKeeperPro.com
¿Preguntas?
888-858-2548
LightKeeperPro.com
bc
= ''1/2 from light set
=Media pulgada de la serie de luces
Defect
Defecto
7.5”
Cut out


Product specificaties

Merk: LightKeeper Pro
Categorie: Niet gecategoriseerd
Model: TEST-200

Heb je hulp nodig?

Als je hulp nodig hebt met LightKeeper Pro TEST-200 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Niet gecategoriseerd LightKeeper Pro

Handleiding Niet gecategoriseerd

Nieuwste handleidingen voor Niet gecategoriseerd