Liftmaster CSW24UL Handleiding


Lees hieronder de 📖 handleiding in het Nederlandse voor Liftmaster CSW24UL (56 pagina's) in de categorie Niet gecategoriseerd. Deze handleiding was nuttig voor 50 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/56
COMMERCIAL DC
VEHICULAR SWING GATE OPERATOR
INSTALLATION MANUAL
LiftMaster
300 Windsor Drive
Oak Brook, IL 60523
• THIS PRODUCT IS TO BE INSTALLED AND
SERVICED BY A TRAINED GATE SYSTEMS
TECHNICIAN ONLY.
• This model is for use on vehicular passage
gates ONLY and not intended for use on
pedestrian passage gates.
• This model is intended for use in Class I, II,
III and IV vehicular swing gate applications.
• Visit LiftMaster.com to locate a professional
installing dealer in your area.
• This gate operator is compatible with MyQ®
and Security+ 2.0® accessories.
ess installation and technical support
des or register this product
Send it in by texting the
photo to 71403.
Take a photo of the camera
icon including the points ( ).
1.
2.
Acc
e
g
ui
d
CSW24ULTECH
Model CSW24UL
2
SAFETY 2
Safety Symbol and Signal Word Review ................................................2
Usage Class ...........................................................................................3
UL325 Entrapment Protection Requirements ........................................3
Safety Installation Information ...............................................................4
Gate Construction Information ...............................................................5
INTRODUCTION 6
Carton Inventory ....................................................................................6
Operator Specifications ..........................................................................7
Site Preparation .....................................................................................8
Check Your Gate ....................................................................................8
INSTALLATION 9
Types of Installations .............................................................................9
Step 1 Determine Location for Concrete Pad and Operator .................10
Step 2 Concrete Pad and Operator Attachment ...................................12
Step 3 Position the Gate Bracket .........................................................13
Step 4 Adjust the Operator Arm Length ...............................................13
Step 5 Secure the Operator Arm ..........................................................14
Step 6 Install Entrapment Protection ...................................................15
Step 7 Earth Ground Rod .....................................................................17
Step 8 Power Wiring ............................................................................17
Step 9 Connect Batteries .....................................................................19
Step 10 Dual Gate Setup ......................................................................21
Step 11 Install the Cover .....................................................................23
ADJUSTMENT 24
Limit and Force Adjustment .................................................................24
Obstruction Test ..................................................................................25
PROGRAMMING 26
Remote Controls (Not Provided) .........................................................26
LiftMaster Internet Gateway (not provided) .........................................27
Erase All Codes ....................................................................................27
Erase limits ..........................................................................................27
Gate Hold Open Feature .......................................................................27
To Remove and Erase Monitored Entrapment Protection Devices .......27
OPERATION 28
Gate Operator Setup Examples ............................................................28
Control Board Overview .......................................................................29
Manual Disconnect ..............................................................................30
Reset Switch ........................................................................................30
Operator Alarm ....................................................................................30
Remote Control ....................................................................................30
ACCESSORY WIRING 31
External Control Devices ......................................................................31
Locks ...................................................................................................32
Miscellaneous Wiring ...........................................................................32
EXPANSION BOARD 33
Expansion Board Overview ..................................................................33
Aux relay 1 and 2 .................................................................................34
Wiring Accessories to the Expansion Board ........................................35
MAINTENANCE 36
Important Safety Instructions ..............................................................36
Maintenance Chart ...............................................................................36
Batteries ...............................................................................................37
TROUBLESHOOTING 38
Diagnostic Codes .................................................................................38
Diagnostic Codes Table .......................................................................39
Control Board LEDs .............................................................................41
Troubleshooting Chart .........................................................................42
APPENDIX 45
Step 8 Solar Panel(s) ...........................................................................45
SAMS Wiring with Relays Not Energized .............................................49
Dual Gate Settings ...............................................................................49
Limit Setup with a Remote Control ......................................................50
WIRING DIAGRAM 51
REPAIR PARTS 52
ACCESSORIES 53
WARRANTY 55
WARNING: This product can expose you to chemicals including lead, which are known to the State of California to cause cancer or birth defects
or other reproductive harm. For more information go to www.P65Warnings.ca.gov.
When you see these Safety Symbols and Signal Words on the following pages, they will alert
you to the possibility of if you do not comply with the warnings that Serious Injury or Death
accompany them. The hazard may come from something mechanical or from electric shock.
Read the warnings carefully.
When you see this Signal Word on the following pages, it will alert you to the possibility of
damage to your gate and/or the gate operator if you do not comply with the cautionary
statements that accompany it. Read them carefully.
IMPORTANT NOTE:
• BEFORE attempting to install, operate or maintain the operator, you must read and fully
understand this manual and follow all safety instructions.
• DO NOT attempt repair or service of your gate operator unless you are an Authorized
Service Technician.
MECHANICAL
ELECTRICAL
TABLE OF CONTENTS
SAFETY
Safety Symbol and Signal Word Review
3
Usage Class
Class I - Residential Vehicular Gate Operator
A vehicular gate operator (or system) intended for use in garages or
parking areas associated with a residence of one-to four single families.
Class II - Commercial/General Access Vehicular
Gate
A vehicular gate operator (or system) intended for use in a commercial
location or building such as a multi-family housing unit (five or more
single family units), hotel, garages, retail store, or other buildings
accessible by or servicing the general public.
Class III - Industrial/Limited Access Vehicular
Gate
A vehicular gate operator (or system) intended for use in an industrial
location or building such as a factory or loading dock area or other
locations not accessible by or intended to service the general public.
Class IV - Restricted Access Vehicular Gate
Operator
A vehicular gate operator (or system) intended for use in a guarded
industrial location or building such as an airport security area or other
restricted access locations not servicing the general public, in which
unauthorized access is prevented via supervision by security personnel.
UL325 Entrapment Protection Requirements
lAminimum of two independent* monitored entrapment protection
devices are required to be installed at each entrapment zone
lEvery installation is unique. It is the responsibility of the installer to
install external monitored entrapment protection devices in each
entrapment zone
lThis vehicular swing gate operator will operate only after installation
of a minimum of two independent* monitored entrapment protection
devices in either the open or close direction. If no entrapment zone
exists in the other direction of gate travel, then the inherent (built into
the operator) is all that is required in that direction.
lEntrapment protection device types include inherent (built into the
operator), monitored external photoelectric sensors or monitored
external edge sensors
lThis operator is provided with an inherent entrapment protection
device built into the operator that serves as one of the two
independent devices
* Independent - the same type of device shall NOT be used for both
entrapment protection devices.
IMPORTANT SAFETY
INSTRUCTIONS
To reduce the risk of INJURY or DEATH:
lREAD AND FOLLOW ALL INSTRUCTIONS.
lNEVER let children operate or play with gate controls. Keep the
remote control away from children.
lALWAYS keep people and objects away from the gate. NO ONE
SHOULD CROSS THE PATH OF THE MOVING GATE.
lTest the gate operator monthly. The gate MUST reverse on contact
with an object or reverse when an object activates the noncontact
sensors. After adjusting the force or the limit of travel, retest the
gate operator. Failure to adjust and retest the gate operator properly
can increase the risk of INJURY or DEATH.
lUse the emergency release ONLY when the gate is not moving.
lKEEP GATES PROPERLY MAINTAINED. Read the owner’s manual.
Have a qualified service person make repairs to gate hardware.
lThe entrance is for vehicles ONLY. Pedestrians MUST use separate
entrance.
l
l
l
ll SAVE THESE
INSTRUCTIONS.
SAFETY


Product specificaties

Merk: Liftmaster
Categorie: Niet gecategoriseerd
Model: CSW24UL

Heb je hulp nodig?

Als je hulp nodig hebt met Liftmaster CSW24UL stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Niet gecategoriseerd Liftmaster

Handleiding Niet gecategoriseerd

Nieuwste handleidingen voor Niet gecategoriseerd