Klein Tools MM300 Handleiding


Lees hieronder de 📖 handleiding in het Nederlandse voor Klein Tools MM300 (36 pagina's) in de categorie Multimeter. Deze handleiding was nuttig voor 2 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/36
INSTRUCTION MANUAL
ENGLISH
MM300
10A
2M
Ω
• DATA HOLD
• AUDIBLE
CONTINUITY
• BATTERY TEST
• DIODE TEST
FRANÇAIS pg. 25
ESPAÑOL pg. 13
Manual-Ranging
Digital Multi
2
GENERAL SPECIFICATIONS
Klein Tools MM300 is a manual ranging multimeter that measures
AC/DC voltage, DC current, and resistance. It can also test batteries,
diodes, and continuity.
• Operating Altitude: 6562 ft. (2000m)
• Relative Humidity: <80% non-condensing
• Operating Temp: °32°F to 104°F (0°F to 40 C)
• Storage Temp: 14°C to 140°F (-10°C to 60°C)
• Accuracy: Values stated at 65° to 83°F (18° to 28°C)
• Temp Coef cient: °0.1 x (Quoted Accuracy) per C above
28 C or below 18 C, corrections are required when ambient ° °
working temp is outside of Accuracy Temp range
• Dimensions: 6.04" x 3.07" x 1.78" (153.4 x 78.0 x 45.2 mm)
• Weight: 8.1 oz. (230 g)
• Calibration: Accurate for one year
• Standards: Conforms to: UL STD 61010-1, 61010-2-030,
61010-2-033.
Certified to: CSA STD C22.2 # 61010-1,
61010-2-030, 61010-2-033.
IEC EN 61010-1, 61010-2-030,
61010-2-033, 61326-1.
• Pollution degree: 2
• Accuracy: ± (% of reading + # of least significant digits)
• Drop Protection: 3.3 ft. (1m)
• Safety Rating: CAT III 600V, Class 2, Double insulation
CAT III: Measurement category III is applicable to test and
measuring circuits connected to the distribution part of the
building’s low-voltage MAINS installation.
• Electromagnetic Environment: IEC EN 61326-1. This
equipment meets requirements for use in basic and controlled
electromagnetic environments like residential properties,
business premises, and light-industrial locations.
Specifications subject to change.
ENGLISH
3
ELECTRICAL SPECIFICATIONS
Function Range Resolution Accuracy
DC Voltage
(V DC)
200.0mV 0.1mV
±(0.5% + 3 digits)2000mV 1mV
20.00V 0.01V
200.0V 0.1V ±(0.8% + 3 digits)
600V 1V
AC Voltage
(V AC)
200.0V 0.1V ±(1.2% + 10 digits)
50 to 60Hz
600V 1V
DC Current
(A DC)
200.0μA 0.1μA ±(1.0% + 5 digits)
20.00mA 10μA
200.0mA 100μA ±(1.2% + 5 digits)
10.00A 10mA ±(3.0% + 5 digits)
Resistance
200.0Ω 0.1Ω
±(1.0% + 5 digits)
2000Ω 1Ω
20.00kΩ 0.01kΩ
200.0kΩ 0.1kΩ
2000kΩ 1kΩ ±(1.5% + 5 digits)
Battery Test 9V 10mV ±(1.0% + 2 digits)
1.5V 10mV ±(1.0% + 2 digits)
• Diode Test: Approx. 1mA, open circuit voltage 2.0V DC
• Audible signal <100ΩContinuity Check:
• Battery Test: 9V (6mA); 1.5V (100mA)
• 2 samples per secondSampling Frequency:
• "OL" indicated on display, overload protection Overload:
600V RMS in all settings
• "-" on display indicates negative polarityPolarity:
• 3 ½ digit, 2000 Count LCDDisplay:


Product specificaties

Merk: Klein Tools
Categorie: Multimeter
Model: MM300
Kleur van het product: Black, Orange
Gewicht: 231 g
Breedte: 80 mm
Diepte: 45 mm
Hoogte: 152 mm
Stroombron: Batterij/Accu
Ondersteuning voor plaatsing: Draagbare multimeter
Ondersteund aantal accu's/batterijen: 2
Type product: Digitale multimeter
Type batterij: AAA
Meetcategorie: CAT III 600V

Heb je hulp nodig?

Als je hulp nodig hebt met Klein Tools MM300 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Multimeter Klein Tools

Handleiding Multimeter

Nieuwste handleidingen voor Multimeter