INSTRUCTION MANUAL
ENGLISH
MM300
10A
2M
Ω
• DATA HOLD
• AUDIBLE
CONTINUITY
• BATTERY TEST
• DIODE TEST
FRANÇAIS pg. 25
ESPAÑOL pg. 13
Manual-Ranging
Digital Multi
2
GENERAL SPECIFICATIONS
Klein Tools MM300 is a manual ranging multimeter that measures
AC/DC voltage, DC current, and resistance. It can also test batteries,
diodes, and continuity.
• Operating Altitude: 6562 ft. (2000m)
• Relative Humidity: <80% non-condensing
• Operating Temp: °32°F to 104°F (0°F to 40 C)
• Storage Temp: 14°C to 140°F (-10°C to 60°C)
• Accuracy: Values stated at 65° to 83°F (18° to 28°C)
• Temp Coef cient: °0.1 x (Quoted Accuracy) per C above
28 C or below 18 C, corrections are required when ambient ° °
working temp is outside of Accuracy Temp range
• Dimensions: 6.04" x 3.07" x 1.78" (153.4 x 78.0 x 45.2 mm)
• Weight: 8.1 oz. (230 g)
• Calibration: Accurate for one year
• Standards: Conforms to: UL STD 61010-1, 61010-2-030,
61010-2-033.
Certified to: CSA STD C22.2 # 61010-1,
61010-2-030, 61010-2-033.
IEC EN 61010-1, 61010-2-030,
61010-2-033, 61326-1.
• Pollution degree: 2
• Accuracy: ± (% of reading + # of least significant digits)
• Drop Protection: 3.3 ft. (1m)
• Safety Rating: CAT III 600V, Class 2, Double insulation
CAT III: Measurement category III is applicable to test and
measuring circuits connected to the distribution part of the
building’s low-voltage MAINS installation.
• Electromagnetic Environment: IEC EN 61326-1. This
equipment meets requirements for use in basic and controlled
electromagnetic environments like residential properties,
business premises, and light-industrial locations.
Specifications subject to change.
ENGLISH
3
ELECTRICAL SPECIFICATIONS
Function Range Resolution Accuracy
DC Voltage
(V DC)
200.0mV 0.1mV
±(0.5% + 3 digits)2000mV 1mV
20.00V 0.01V
200.0V 0.1V ±(0.8% + 3 digits)
600V 1V
AC Voltage
(V AC)
200.0V 0.1V ±(1.2% + 10 digits)
50 to 60Hz
600V 1V
DC Current
(A DC)
200.0μA 0.1μA ±(1.0% + 5 digits)
20.00mA 10μA
200.0mA 100μA ±(1.2% + 5 digits)
10.00A 10mA ±(3.0% + 5 digits)
Resistance
200.0Ω 0.1Ω
±(1.0% + 5 digits)
2000Ω 1Ω
20.00kΩ 0.01kΩ
200.0kΩ 0.1kΩ
2000kΩ 1kΩ ±(1.5% + 5 digits)
Battery Test 9V 10mV ±(1.0% + 2 digits)
1.5V 10mV ±(1.0% + 2 digits)
• Diode Test: Approx. 1mA, open circuit voltage 2.0V DC
• Audible signal <100ΩContinuity Check:
• Battery Test: 9V (6mA); 1.5V (100mA)
• 2 samples per secondSampling Frequency:
• "OL" indicated on display, overload protection Overload:
600V RMS in all settings
• "-" on display indicates negative polarityPolarity:
• 3 ½ digit, 2000 Count LCDDisplay:


Product specificaties

Merk: Klein Tools
Categorie: Multimeter
Model: MM300
Kleur van het product: Black, Orange
Gewicht: 231 g
Breedte: 80 mm
Diepte: 45 mm
Hoogte: 152 mm
Stroombron: Batterij/Accu
Ondersteuning voor plaatsing: Draagbare multimeter
Ondersteund aantal accu's/batterijen: 2
Type product: Digitale multimeter
Type batterij: AAA
Meetcategorie: CAT III 600V

Heb je hulp nodig?