Kern ORA 1RE Handleiding
Kern
Meetapparatuur
ORA 1RE
Lees hieronder de 📖 handleiding in het Nederlandse voor Kern ORA 1RE (2 pagina's) in de categorie Meetapparatuur. Deze handleiding was nuttig voor 5 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld
Pagina 1/2
1
6
5
3
2
4
2
4
5
3
6
1
CONTENT S
1 Technical data 1 .................................................................................................
2 Description .....................................................................................................2
3 General information 3 .......................................................................................
3.1 Intended use 3 ...................................................................................................
3.2 Intended use 3 ...................................................................................................
4 Basic safety information 4 ................................................................................
4.1 Follow the instructions in the operating manual 4 ..........................................
4.2 Warranty ..................................................................................................... 4-5
5 Supplied items 5 ................................................................................................
6 Before the first use 6 .........................................................................................
7 Use/measurement .........................................................................................7
7.1 Additional advice 8 ............................................................................................
7.2 Measuring procedure 8-9 .................................................................................
8 Cleaning and maintenance 10 ..........................................................................
9 Storage ......................................................................................................... 10
10 Service ......................................................................................................... 11
11 Disposal ....................................................................................................... 11
12 Additional information................................................................................. 12
13 Brix to refractive index (nD) conversion table 12-13 .......................................
14 Annex ........................................................................................................... 14
1. Technische Daten
Models
KERN
Measuring range
and Scales
Scale gradua-
tions Accuracy
Dimensions
Product
Net weight
ORA 90BE
Brix: 0-42%
Brix: 42-71%
Brix: 71-90%
0,2 % Brix
0,2 % Brix
0,2 % Brix
200x40x40mm 0,600kg
ORA 1RE RI: 1,333-
1,5200 nD 0,005 nD 200x40x40mm 0,600kg
Operating manual
Analogue refractometer
KERN & Sohn GmbH
KERN ORA 90 BE
Analogue Expert 3x Brix scale
ORA 1 RE
Analogue Expert 3x nD scale
Ziegelei 1
D-72336 Balingen
E-Mail: info@kern-sohn.com
Tel: +49-[
0]7433 -9933-0
Fax: +49-[
0]7433-9933-149
Internet: www.kern-sohn.com
3. General information
3.1 Intended use
The refractometer is a measuring instrument for determining the refractive index of
transparent substances in liquid or in some cases also in the solid state. It is used
to observe the behaviour of light as it passes from a prism with known properties
to the substance being tested.
Use of the refractometer for other purposes is contrary to its intended use and
may be hazardous. The manufacturer shall not be liable for any damages caused by
improper use.
3.2 Warranty
The warranty shall be void in the event of:
▸ Failure to observe the instructions in the operating manual
▸ Use for purposes other than those described
▸ Modifications or opening the device housing
▸ Mechanical damage and/or damage resulting from media, liquids,
natural wear and tear
2. Description
1. Prism cover
2. Prism surface
3. Adjusting wheel measuring range
4. Dispersion adjusting ring
5. Optical tubes
6. Eyepiece with diopter
adjustment ring
Version 1. 0 /2012 4 9
4. Basic safety information
4.1 Follow the instructions in the operating manual
▸ Carefully read through the operating manual even if you have prior
experience with KERN refractometers.
▸ Every language version includes a non-authoritative translation.
The original German document is the definitive version.
4.2 Warning
▸ Do not let acids come into contact with skin or eyes. If acid comes into contact
with skin, flush with copious amounts of water. Shower if larger areas of skin are
affected.
▸ If acid comes into contact with eyes, keep the eyelid open and flush the eye with
running lukewarm water from the outer corner to the inner corner. Flush eyes for
at least 15 minutes. Then consult a doctor or ophthalmologist immetdiately.
▸ Thoroughly clean the refractometer aer each use.
▸ The refractometer must not be exposed to extreme temperatures, high
mechanical stresses, strong direct sunlight or high humidity.
▸ This refractometer is not a toy. Keep out of reach of children.
▸ Make sure that you will not be hit by anything else while you are using the re-
fractometer, as this could cause serious eye injuries
▸ The rubber eyeshade may cause irritation when in prolonged contact with the
skin. If this happens, consult your doctor.
▸ Do not touch the lenses with your fingers.
5. Supplied items
Aer unpacking and before using the device for the first time, check that all
listed parts have been supplied. Replace damaged or faulty parts immediately
and do not put them into operation.
▸ Refractometer
▸ Storage box
▸ Pipette
▸ Tools
▸ Cleaning cloth
6. Before the first use
Remove the protective film (if present) from the prism surface [2] and move the
measuring range adjusting wheel
[3] to position 1.
Example scale on
ORA 90 BE
7. Storage box
8. Pipette
9. Refractometer
10.
11.
Tools
Cleaning cloth
GB
!The refractometer cannot be used for the measurement of oil-based fluids.
14
8
9
10
12
11
13
7. Use/measurement
▸ The refractometer can be used to quickly and accurately determine the refractive
index of transparent substances, liquid or solid ones. Please make sure your hands
are dry before handling the measuring device.
▸ The measuring instrument has three measuring ranges. Please use the measuring
range adjusting wheel on the underside of the casing to switch measuring ranges.
▸ The light falling on the prism can be changed using a rotating flap on the underside
of the prism.
▸ In addition, the refractometer is provided with an adjusting ring
[4], which can
reduce chromating, primarily with low liquid concentrations.
▸ The light/dark transition is clearly visible.
Important!
The ambient/room temperature and the sample temperature influence
the refractometer measuring result.
The scales are designed for an ambient temperature of +20 °C!
If the measurements are carried out at a temperature other than +20 °C,
the results must be correspondingly corrected.
A correction table can be found in the annex, Point 1 .4
7.1 Additional advice
It is important that the samples being measured are representative samples.
Measurements should be carried out quickly on samples that evaporate easily. The
samples should be at the same temperature as the measuring instrument in order
to achieve an accurate result.
7.2 Measuring procedure
▸ Make sure your hands are dry before handling the refractometer.
▸ Open the prism cover
[1] and use the supplied pipette [8] to apply a few drops of
the sample liquid [8] onto the prism surface [2], then close the prism cover [1].
Spread the liquid evenly by pressing down on the prism cover
[1
].
▸ Hold the device horizontally and wait about 30 seconds (
for optimal temperature
equalisation between the sample and device).
▸ View the measurement scale through the eyepiece [6]. Point the prism surface [2]
of the refractometer at a bright light source while doing this.
▸ The light falling on the prism can be changed using a rotating flap on the
underside of the prism.
▸ Rotate the adjustment ring [6] on the eyepiece [6] to adjust the focus.
▸ The boundary line will move on the measurement scale depending on the concen-
tration. This bright/dark boundary line shows the result directly on the scale.
▸ The measuring instrument has three measuring ranges. Please use the measuring
range adjusting wheel on the underside of the casing to switch measuring ranges.
▸ The light/dark boundary can be brought into sharp focus using the dispersion
adjusting ring [6]. This is useful for low liquid concentrations.
▸ If the temperature deviates from +20 °C, correct the measured result using the
corresponding value from the temperature correction table
(Point 14).
▸ Carefully clean the supplied pipette
[8] and the refractometer aer carrying out
the measurement.
Important!
Aer every measurement, use a lint-free, absorbent cloth to remove
the fluids from the prism surface [2] and prism cover [1]. Then
carefully clean the prism and prism cover using a cloth moistened
with water or if necessary alcohol, and dry both parts using a so,
dry and lint-free cloth. Avoid rubbing the prism
[2].
8. Cleaning and maintenance
Clean the refractometer using a so, lint-free cloth moistened with water, or if
necessary alcohol. Do not use any aggressive or abrasive cleaning agents. Never
immerse the device in water or hold it under running water. Never handle the device
with wet or damp hands.
Never touch the measuring prism [2] with hard tools made from plastic, wood,
rubber, metal, glass etc. Hard objects can quickly damage the relatively so prism
glass, resulting in measurement errors.
The refractometer is maintenance-free.
Cleaning should be carried out immediately before and aer each use of the
refractometer to maximise its life and optimise measurement results.
9. Storage
Store the refractometer in a dry, non-corrosive environment, preferably between
10°C and 30 °C.
9
10. Service
Aer reading this operating manual, if you have any questions about setting up or
using the refractometer, or if any unexpected problem occurs, please contact your
dealer. The device housing may only be opened by trained service technicians
authorised by KERN.
11. Disposal
The packaging consists of environmentally friendly materials which can be disposed
of via local recycling facilities.
The device and storage box should be disposed of by the operator in accordance
with applicable national or regional regulations at the place of use.
12. Additional information
The product may differ slightly from the illustrations.
Avoid exposing the refractometer to direct sunlight!
Never bring the refractometer into contact with solvents.
!
!
14. Annex
Table 1: International Temperature Correction Table for °Brix
(% sugar gradient)
Correct the result by the following values
(refractometer must be correctly
calibrated at 20 °C).
BRIX
Refractive
index BRIX
Refractive
index BRIX
Refractive
index
% % % nD nD nD
0 1.33299 30 1.38115 60 1.44193
1 1.33442 31 1.38296 61 1.44420
2 1.33586 32 1.38478 62 1.44650
3 1.33732 33 1.38661 63 1.44881
4 1.33879 34 1.38846 64 1.45113
5 1.34026 35 1.39032 65 1.45348
6 1.34175 36 1.39220 66 1.45584
7 1.34325 37 1.39409 67 1.45822
8 1.34476 38 1.39600 68 1.46061
9 1.34629 39 1.39792 69 1.46303
10 1.34782 40 1.39986 70 1.46546
11 1.34937 41 1.40181 71 1.46792
12 42 1.40378 72 1.47037 1.35093
13 43 73 1.47285 1.35250 1.40576
14
1.35408
44
1.40776
74
1.47535
15 45 1.40978 75 1.47787 1.35568
16
1.35729
46
1.41181
76
1.48040
17 47 1.41385 77 1.48295 1.35891
18 48 78 1.36054 1.41592 1.48552
19 1.36218 49 1.41799 79 1.4881
20 1.36384 1.42009 80 1.49071 50
21 1.42220 81 1.49333 1.36551 51
22 1.36720 1.42432 82 52 1.49597
23 1.36889 1.42647 83 1.49862 53
24 1.37060 1.42862 84 54 1.50129
25 1.37233 1.43080 85 55 1.50398
26 1.37406 1.43299 56
27 1.37582 57 1.43520
28 1.43743 1.37758 58
29 1.37936 1.43967 59
% Brix
reading
0.0 5.0 10.0 15.0 20.0 25.0 30.0 35.0 40.0 45.0 50.0 55.0 60.0 65.0 70.0 75.0 80.0 85.0
Temperature °C
10.0 - - - - - - - - - - - - - - - - - -0.53 0.56 0.59 0.62 0.65 0.67 0.69 0.71 0.72 0.73 0.74 0.75 0.75 0.75 0.75 0.75 0.74 0.73
11.0 - - - - - - - - - - - - - - - - - -0.49 0.52 0.54 0.57 0.59 0.61 0.63 0.64 0.65 0.66 0.67 0.68 0.68 0.68 0.68 0.67 0.67 0.66
12.0
- 0.44
- 0.47
- 0.49
- 0.51
- 0.53
- 0.55
- 0.56
- 0.57
- 0.58
- 0.59
- 0.60
- 0.60
- 0.61
- 0.61
- 0.60
- 0.60
- 0.60
-0.59
13.0
- - - - - - - - - - - - - - - - - -0.40 0.41 0.43 0.45 0.47 0.48 0.50 0.51 0.52 0.52 0.53 0.53 0.53 0.53 0.53 0.53 0.52 0.52
14.0 - - - - - - - - - - - - - - - - - -0.34 0.36 0.38 0.39 0.40 0.42 0.43 0.44 0.44 0.45 0.45 0.46 0.46 0.46 0.46 0.45 0.45 0.44
15.0
- - - - - - - - - - - - - - - - - -0.29 0.31 0.32 0.33 0.34 0.35 0.36 0.37 0.37 0.38 0.38 0.38 0.38 0.38 0.38 0.38 0.37 0.37
16.0
- 0.24
- 0.25
- 0.26
- 0.27
- 0.28
- 0.28
- 0.29
- 0.30
- 0.30
- 0.30
- 0.31
- 0.31
- 0.31
- 0.31
- 0.31
- 0.30
- 0.30
-0.30
17.0
- - - - - - - - - - - - - - - - - -0.18 0.19 0.20 0.20 0.21 0.21 0.22 0.22 0.23 0.23 0.23 0.23 0.23 0.23 0.23 0.23 0.23 0.22
18.0 - - - - - - - - - - - - - - - - - -0.12 0.13 0.13 0.14 0.14 0.14 0.15 0.15 0.15 0.15 0.15 0.15 0.15 0.15 0.15 0.15 0.15 0.15
19.0
- - - - - - - - - - - - - - - - - -0.06 0.06 0.07 0.07 0.07 0.07 0.07 0.08 0.08 0.08 0.08 0.08 0.08 0.08 0.08 0.08 0.08 0.07
20.0
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
21.0
0.06 0.07 0.07 0.07 0.07 0.07 0.08 0.08 0.08 0.08 0.08 0.08 0.08 0.08 0.08 0.08 0.08 0.07
22.0 0.13 0.14 0.14 0.14 0.15 0.15 0.15 0.15 0.16 0.16 0.16 0.16 0.16 0.16 0.15 0.15 0.15 0.15
23.0
0.20 0.21 0.21 0.22 0.22 0.23 0.23 0.23 0.23 0.24 0.24 0.24 0.24 0.23 0.23 0.23 0.23 0.22
24.0
0.27
0.28
0.29
0.29
0.30
0.30
0.31
0.31
0.31
0.32
0.32
0.32
0.32
0.31
0.31
0.31
0.30
0.30
25.0 0.34 0.35 0.36 0.37 0.38 0.38 0.39 0.39 0.40 0.40 0.40 0.40 0.40 0.39 0.39 0.39 0.38 0.37
26.0 0.42 0.43 0.44 0.45 0.46 0.46 0.47 0.47 0.48 0.48 0.48 0.48 0.48 0.47 0.47 0.46 0.46 0.46
27.0
0.50 0.51 0.52 0.53 0.54 0.55 0.55 0.56 0.56 0.56 0.56 0.56 0.56 0.55 0.55 0.54 0.53 0.52
28.0
0.58
0.59
0.60
0.61
0.62
0.63
0.64
0.64
0.64
0.65
0.65
0.64
0.64
0.64
0.63
0.62
0.61
0.60
29.0
0.66 0.67 0.68 0.69 0.70 0.71 0.72 0.73 0.73 0.73 0.73 0.73 0.72 0.72 0.71 0.70 0.69 0.68
30.0 0.74 0.75 0.77 0.78 0.79 0.80 0.81 0.81 0.81 0.82 0.81 0.81 0.81 0.80 0.79 0.78 0.77 0.75
13. Brix to refractive index (nD) conversion table
Data from „ICUMSA“ International Commission for Uniform Methods
of Sugar Analysis, at 20 °C and 589 nm wavelength.
Product specificaties
Merk: | Kern |
Categorie: | Meetapparatuur |
Model: | ORA 1RE |
Heb je hulp nodig?
Als je hulp nodig hebt met Kern ORA 1RE stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding Meetapparatuur Kern
27 Januari 2025
27 Januari 2025
27 Januari 2025
27 Januari 2025
27 Januari 2025
27 Januari 2025
27 Januari 2025
27 Januari 2025
27 Januari 2025
27 Januari 2025
Handleiding Meetapparatuur
- Meetapparatuur Bosch
- Meetapparatuur Panasonic
- Meetapparatuur DeWalt
- Meetapparatuur Fysic
- Meetapparatuur Honeywell
- Meetapparatuur Pioneer
- Meetapparatuur Topcom
- Meetapparatuur ABB
- Meetapparatuur Ade
- Meetapparatuur Aktobis
- Meetapparatuur Albrecht
- Meetapparatuur Alecto
- Meetapparatuur Amprobe
- Meetapparatuur Ansmann
- Meetapparatuur AS - Schwabe
- Meetapparatuur Basetech
- Meetapparatuur Be Cool
- Meetapparatuur Beha-Amprobe
- Meetapparatuur Benning
- Meetapparatuur Beurer
- Meetapparatuur Bresser
- Meetapparatuur Bruder Mannesmann
- Meetapparatuur Burg-Wachter
- Meetapparatuur Danfoss
- Meetapparatuur Digitus
- Meetapparatuur Duro Pro
- Meetapparatuur EBERLE
- Meetapparatuur Einhell
- Meetapparatuur Eizo
- Meetapparatuur Elgato
- Meetapparatuur Enda
- Meetapparatuur Entes
- Meetapparatuur Extech
- Meetapparatuur Finder
- Meetapparatuur Flex
- Meetapparatuur Flir
- Meetapparatuur Fluke
- Meetapparatuur Goclever
- Meetapparatuur Goobay
- Meetapparatuur Gossen Metrawatt
- Meetapparatuur Grohe
- Meetapparatuur Gude
- Meetapparatuur Hager
- Meetapparatuur Hama
- Meetapparatuur Holzmann
- Meetapparatuur Homedics
- Meetapparatuur Ideal
- Meetapparatuur IHealth
- Meetapparatuur Kogan
- Meetapparatuur Kopp
- Meetapparatuur LaCie
- Meetapparatuur Laica
- Meetapparatuur Lanaform
- Meetapparatuur Laserliner
- Meetapparatuur Livington
- Meetapparatuur Logilink
- Meetapparatuur Maximum
- Meetapparatuur Megasat
- Meetapparatuur Megger
- Meetapparatuur Metrix
- Meetapparatuur Microlife
- Meetapparatuur Midland
- Meetapparatuur Milwaukee
- Meetapparatuur Mitsubishi
- Meetapparatuur Monacor
- Meetapparatuur Muller
- Meetapparatuur Nedis
- Meetapparatuur PCE
- Meetapparatuur PCE Instruments
- Meetapparatuur Perel
- Meetapparatuur Powerfix
- Meetapparatuur Pyle
- Meetapparatuur Reely
- Meetapparatuur RK Technology
- Meetapparatuur Rossmax
- Meetapparatuur Sanwa
- Meetapparatuur Sekonic
- Meetapparatuur Shimano
- Meetapparatuur Silvercrest
- Meetapparatuur Silverline
- Meetapparatuur Soehnle
- Meetapparatuur Steinberg
- Meetapparatuur Technics
- Meetapparatuur Techno Line
- Meetapparatuur Technoline
- Meetapparatuur TFA
- Meetapparatuur Toolland
- Meetapparatuur Trotec
- Meetapparatuur Truelife
- Meetapparatuur Uni-T
- Meetapparatuur VDO
- Meetapparatuur Velleman
- Meetapparatuur VirtuFit
- Meetapparatuur Voltcraft
- Meetapparatuur Wachendorff
- Meetapparatuur Westfalia
- Meetapparatuur Joy-it
- Meetapparatuur Omnitronic
- Meetapparatuur Oregon Scientific
- Meetapparatuur Black And Decker
- Meetapparatuur Continental Edison
- Meetapparatuur CSL
- Meetapparatuur Klein Tools
- Meetapparatuur Peak
- Meetapparatuur Cocraft
- Meetapparatuur Meec Tools
- Meetapparatuur Soler And Palau
- Meetapparatuur Sauter
- Meetapparatuur Festo
- Meetapparatuur Proficare
- Meetapparatuur Eurolite
- Meetapparatuur SIIG
- Meetapparatuur RIDGID
- Meetapparatuur REV
- Meetapparatuur MSW
- Meetapparatuur SHX
- Meetapparatuur Victron Energy
- Meetapparatuur Carrier
- Meetapparatuur Fantini Cosmi
- Meetapparatuur Vemer
- Meetapparatuur Lund
- Meetapparatuur Testo
- Meetapparatuur Circutor
- Meetapparatuur Eastron
- Meetapparatuur Stabila
- Meetapparatuur Testboy
- Meetapparatuur Hazet
- Meetapparatuur Yato
- Meetapparatuur IFM
- Meetapparatuur Wago
- Meetapparatuur GW Instek
- Meetapparatuur Kyoritsu
- Meetapparatuur Dahua Technology
- Meetapparatuur Owon
- Meetapparatuur Eltako
- Meetapparatuur Cablexpert
- Meetapparatuur Wentronic
- Meetapparatuur Comark
- Meetapparatuur Clean Air Optima
- Meetapparatuur ORNO
- Meetapparatuur Multimetrix
- Meetapparatuur Etymotic
- Meetapparatuur Hameg
- Meetapparatuur PICO
- Meetapparatuur Sonel
- Meetapparatuur YSI
- Meetapparatuur TFA Dostmann
- Meetapparatuur Werma
- Meetapparatuur Greisinger
- Meetapparatuur Testec
- Meetapparatuur Hikmicro
- Meetapparatuur Vimar
- Meetapparatuur Kreg
- Meetapparatuur Kemo
- Meetapparatuur Pancontrol
- Meetapparatuur SRS
- Meetapparatuur H-Tronic
- Meetapparatuur Ebro
- Meetapparatuur X-Rite
- Meetapparatuur Tempest
- Meetapparatuur Arya
- Meetapparatuur PeakTech
- Meetapparatuur Tru Components
- Meetapparatuur Emko
- Meetapparatuur KS Tools
- Meetapparatuur Trumeter
- Meetapparatuur Aeros
- Meetapparatuur Delta Ohm
- Meetapparatuur Aqua Master Tools
- Meetapparatuur Hanna
- Meetapparatuur Atmel
- Meetapparatuur Qualita
- Meetapparatuur MGL Avionics
- Meetapparatuur Adwa
- Meetapparatuur Rigol
- Meetapparatuur Chauvin Arnoux
- Meetapparatuur Aim TTi
- Meetapparatuur AREXX
- Meetapparatuur UHoo
- Meetapparatuur CEM
- Meetapparatuur Jonard Tools
- Meetapparatuur TDE Instruments
- Meetapparatuur CESYS
- Meetapparatuur Angler
- Meetapparatuur Aerospace Logic
- Meetapparatuur Zircon
- Meetapparatuur BJZ
- Meetapparatuur Johnson Level
- Meetapparatuur GMW
- Meetapparatuur SOEKS
- Meetapparatuur Rotronic
- Meetapparatuur Apollo Ultrasonic
- Meetapparatuur Softing
- Meetapparatuur Weltron
- Meetapparatuur Oscium
- Meetapparatuur Janitza
- Meetapparatuur Condtrol
- Meetapparatuur J.P. Instruments
- Meetapparatuur Weidmüller
- Meetapparatuur Ermenrich
- Meetapparatuur Siglent
- Meetapparatuur INFICON
- Meetapparatuur Qubino
- Meetapparatuur Lascar Electronics
- Meetapparatuur HT Instruments
- Meetapparatuur P3 International
- Meetapparatuur Beckmann & Egle
- Meetapparatuur Seek Thermal
- Meetapparatuur Motrona
- Meetapparatuur Kübler
- Meetapparatuur AkYtec
- Meetapparatuur Tempo
- Meetapparatuur Camille Bauer
- Meetapparatuur Blebox
- Meetapparatuur Seaward
- Meetapparatuur HOZO Design
- Meetapparatuur Corentium
- Meetapparatuur GQ
- Meetapparatuur Tektronix
- Meetapparatuur Dostmann Electronic
- Meetapparatuur Murideo
- Meetapparatuur SecuTech
- Meetapparatuur NetPeppers
- Meetapparatuur SensoProtect
- Meetapparatuur Water-i.d.
- Meetapparatuur ZKETECH
- Meetapparatuur LabNation
- Meetapparatuur Electronics International
- Meetapparatuur Cliff
- Meetapparatuur ClimeMET
- Meetapparatuur Fixpoint
- Meetapparatuur Stahlwille
- Meetapparatuur MASIMO
- Meetapparatuur Milesight
- Meetapparatuur Noyafa
- Meetapparatuur Stamos
- Meetapparatuur Brookhuis
- Meetapparatuur Crowcon
- Meetapparatuur Aeroqual
- Meetapparatuur Intact
- Meetapparatuur PQ Plus
- Meetapparatuur DriveTest
- Meetapparatuur Helvi
Nieuwste handleidingen voor Meetapparatuur
29 Januari 2025
29 Januari 2025
29 Januari 2025
27 Januari 2025
27 Januari 2025
27 Januari 2025
27 Januari 2025
27 Januari 2025
27 Januari 2025
27 Januari 2025