Kathrein ZAS 40XL Handleiding


Lees hieronder de ๐Ÿ“– handleiding in het Nederlandse voor Kathrein ZAS 40XL (2 pagina's) in de categorie Niet gecategoriseerd. Deze handleiding was nuttig voor 29 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/2
1 / 2
ZAS 40XS 214500011
ZAS 40XL 214500012
ZAS 41XS 214500013
ZAS 41XL 214500014
Rafter fasteners for the sat antennas CAS 06/60/80/90 and KEA 650/750/850/1000
About this guide
This document is part of the product.
โ–บDo not install or use the device until you have read and understood
this document.
โ–บPerform all operating steps described in this manual in the speci๏ฌ ed
sequence.
โ–บKeep this document for reference throughout the service life of the
device. Pass this document on to any new owner or user.
For the most up-to-date version of this document, go to
www.kathrein-ds.com.
Features
โ—ZAS 40XS/ZAS 40XL for one sat antenna
ZAS 41
XS/ZAS 41XL for one sat antenna
and an additional radio
antenna
โ– Mounting directly from the outside or through the battens onto the
rafter
โ– Flexibly adjustable to the gaps between the rafters by means of a
telescopic tube
โ– Continuously adjustable for any roof slope (limited only by the cover
plate)
โ– Hot-dip galvanised
โ– Cable is inserted through mast tip by means of the ZTC 08 (included
in the scope of delivery of the ZTS๎˜ž40/ZTS 41ro/ZTS 41sw)
โ– Designed to withstand lightning current (100๎˜žkA, 10/350 ยตs according
to DIN VDE 0855-300)
The ZAS 40XS, ZAS 40XL, ZAS 41XS und ZAS 41XL are rafter fasteners for mounting parabolic antennas with a diameter of up to ร˜๎˜ž100๎˜žcm on the roof.
Any other use, or failure to comply with these instructions or documentation and instructions enclosed with the devices, will result in voiding of
warranty or guarantee.
Intended use
Technical data
Type Einheit ZAS๎˜Ÿ40XS ZAS๎˜Ÿ41XS ZAS 40XL ZAS 41XL
Order no. 214500011 214500013 214500012 214500014
Length mm 900 1300 900 1300
Diameter mm 48
Gaps between rafters mm 390 โ€“ 520 870 โ€“ 1100
Roof slope ยฐ 0๎˜žโ€“๎˜ž90
Rafter frame dimensions mm 390 โ€“ 520๎˜žx๎˜ž148๎˜žx๎˜ž40 870 โ€“ 1100๎˜žx๎˜ž148๎˜žx๎˜ž40
Suitable for sat antennas CAS๎˜ž06/CAS๎˜ž60/CAS๎˜ž80/CAS๎˜ž90, KEA 650/750/850/1000
Suitable mounting accessories see โ€žMounting sets ZTS๎˜ž40/ZTS 41ro/ZTS 41swโ€œ on page 1
Packing unit mm 980 x 200 x 115 1380 x 200 x 115 980 x 200 x 115 1380 x 200 x 115
Perm. bending moment Nm 700
Packing unit/weight, approx. pc./kg 1/5,7 1/6,6 1/7,1 1/8,0
Scope of delivery
โ—Rafter fastener
โ—6๎˜žwood screws 10๎˜žx๎˜ž100๎˜žmm
โ—Earthing terminal
โ—Mast cover
โ—4 nuts M10
โ—Fastening screw M10 x 20
โ—User manual
Mounting sets ZTS๎˜Ÿ40/ZTS 41ro/ZTS 41sw
โ—For securing the rafter fasteners ZAS 4x
โ—Consists of:
โ€“ZTB 61: Lead cover plate (410 x 410 mm)
ZTB 60ro/ZTB 60sw: Aluminium cover plate (500 x 450 mm)
โ€“ZTC 08: Mast cap for insertion of eight or ten cables
โ€“ZTC 48: Cover collar (รธ 48๎˜žmm)
900 mm (ZAS 40XS/ZAS 40XL)
1300 mm (ZAS 41XS/ZAS 41XL)
390 โ€“ 520 mm (ZAS 40XS/ZAS 41XS)
870 โ€“ 1100 mm (ZAS 40XL/ZAS 41XL)
โˆ… 48 mm
The items in the sets are
also available individually.
Please ๏ฌ nd further moun-
ting accessories under
www.kathrein-ds.com
www.kathrein-ds.com | support@kathrein-ds.com 936500087/a/A4/STM/0421/GB | Subject to change.
KATHREIN Digital Systems GmbH | Anton-Kathrein-Str. 1โ€“3 | 83022 Rosenheim | Germany | Phone +49 731 270 909 70
Installation
Safety instructions
WARNING!
Danger of falling during assembly work on the roof
.
โ–บThe equipment described may only be installed by trained specialist personnel.
โ–บMake sure that the supporting structure has su๎˜œ cient load-bearing capacity.
โ–บWear stable shoes with non-slip soles.
โ–บMake sure that the roof and climbing aid are dry, clean and non-slip.
โ–บMount the sat antenna (max. รธ 100 cm) only up to a height of 800 mm (see sticker marking).
โ–บFor a mast length of 1300๎˜žmm (ZAS 41XS/ZAS 41XL), install the re๏ฌ‚ ector below and the FM antenna above.
Required tools
โ—Drill bit ร˜ 6.5๎˜žmm
โ—17 AF open-ended spanner
โ—Spirit level
Installing the rafter fastener
1. Remove a su๎˜œ cient number of roof tiles.
2. Extend the rafter fastener to the width of rafters or counter battens.
Align the rafter fastener and the lead cover plate to
suit the covering materials of the roof. Take care to
leave enough overhang above and below the gap in
the roo๏ฌ ng material.
The cross-tube of the ZAS 40 and ZAS 41 rafter faste-
ners has an o๎˜š set of about 2 cm relative to the side
securing clips. Depending on the alignment, this
o๎˜š set allows the rafter fastener to be moved upwards
or downwards within the roof space and, for instance,
in the conjunction with the rafter fastener installation
set ZTS 40, to achieve an optimum position relative
to the existing roof tiles. When installing on steeper
roofs, make sure the shorter securing section points
downwards relative to the slope of the roof.
3. Mark six screw holes on rafters or counter battens.
4. Pre-drill screw holes 50 mm deep using a ร˜ 6,5 mm drill bit.
5. Screw in the six wood screws 10 x 100 mm from above on the rafters
or counter battens using an A7 19 open-ended spanner. If the
counter battens are too thin, place a suitable piece of wood under-
neath the rafter bracket in the areas of the bolts.
6. Tighten the fastening screw of the telescopic tube using an AF 17
open-ended spanner.
7. Place the earthing wire (16 mm2 copper or 25 mm2 aluminium) into
the earthing terminal and tighten the nut.
8. Slide the mast along the telescopic tube in such a way that the
cover plate matches the joints of the roof tiles.
9. If you intend to lead cables through the mast tip, remove the mast
cap.
10. Swing the mast towards the gable and pull the cover plate and the
cover collar over the mast tip.
11. Mark six screw holes on rafters or counter battens.
12. Pre-drill screw holes 50 mm deep using a ร˜ 6,5 mm drill bit.
13. Screw in the six wood screws 10 x 100 mm from above on the rafters
or counter battens using an A7 19 open-ended spanner. If the
counter battens are too thin, place a suitable piece of wood under-
neath the rafter bracket in the areas of the bolts.
14. Tighten the fastening screw of the telescopic tube using an AF 17
open-ended spanner.
15. Place the earthing wire (16 mm2 copper or 25 mm2 aluminium) into
the earthing terminal and tighten the nut.
16. Slide the mast along the telescopic tube in such a way that the
cover plate matches the joints of the roof tiles.
17. If you intend to lead cables through the mast tip, remove the mast
cap.
18. Swing the mast towards the gable and pull the cover plate and the
cover collar over the mast tip


Product specificaties

Merk: Kathrein
Categorie: Niet gecategoriseerd
Model: ZAS 40XL

Heb je hulp nodig?

Als je hulp nodig hebt met Kathrein ZAS 40XL stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Niet gecategoriseerd Kathrein

Handleiding Niet gecategoriseerd

Nieuwste handleidingen voor Niet gecategoriseerd