Temperature Management Center plate for Timer Thermostat
Timer Thermostat insert
Ref.no.: UT 238 D, UT 238 E
Operating Instructions
Center plate for Timer Thermostat/ Insert
Operating Instructions Center plate for Timer Thermostat/ Insert .... 1
1. Starting up the Timer Thermostat ................................................... 2
1.1. Prolonging the heating phase (party function).............................. 3
1.2. Changing over to the lowering temperature (economy button) .... 3
1.3. Switching for longer periods to the lowering temperature ............ 4
1.4. Setting the individual temperature ................................................ 4
1.5. Push button lock-out ..................................................................... 5
2. Settings in the program menu ......................................................... 6
2.1. Setting the date and time – Uhr menu item.................................. 6
2.2. Modifying the temperature steps – tEMP menu item.................... 7
2.3. Checking the anti-freeze temperature .......................................... 7
2.4. Modifying the time program - ProG menu item............................. 8
2.5. Inserting a new switching time.................................................... 10
2.6. Aborting the settings at the time program................................... 11
2.7. Setting the holiday program – UrLb menu item.......................... 11
2.8. Activating/deactivating the anti-freeze function – FrSt menu item
13
Mounting Instructions and Commissioning for the Electrician........ 14
3. Installation........................................................................................ 14
3.1. Installation and safety instructions.............................................. 14
4. Mounting .......................................................................................... 15
5. Electrical connection ...................................................................... 15
5.1. Safety function ............................................................................ 16
6. Technical data ................................................................................. 21
7. Guarantee......................................................................................... 22
Stand: Jul-08 0024094100
Temperature Management Center plate for Timer Thermostat
Timer Thermostat insert
Ref.no.: UT 238 D, UT 238 E
How the Timer Thermostat functions
Your Timer Thermostat functions similarly to a time delay switch – at
specific times which can be set, your heating system is regulated by the
Timer Thermostat to three temperatures which can be set.
The comfort temperature is usually used for the daytime, put
more precisely for the periods when you are present.
The lowering temperature is usually used for the night. It is also
called the economy temperature.
The anti-freeze temperature is usually used for longer periods of
absence (e.g. holidays). The temperature is just high enough to
protect the heating system against freezing.
1. Starting up the Timer Thermostat
When the Timer Thermostat is switched on for the first time as well as
after long deactivation periods, e.g. after a mains failure, the Timer
Thermostat jumps automatically to the time input - the current data has to
be entered here.
(you can edit these data later --> for further information please refer to
”Setting the date and time – Uhr menu item” on Page 7).
The hour display flashes
Press the + or - button until the desired hour has been set.
L Time format
You can have the time displayed in international 24 hour format
(0H...23H) or in the English-speaking a.m. (12AM...11AM) and p.m.
format (12PM...11PM). When you set the clock, the display begins
with the 24- hour format, followed by the AM/PM format. Depending on
the hour format which you conrm with S, the time is displayed in
future in 24- hour format or in AM/PM format.
Press the S button.
2
Temperature Management Center plate for Timer Thermostat
Timer Thermostat insert
Ref.no.: UT 238 D, UT 238 E
The hour is set and the minute display ashes.
You now have to enter all the further data in the same manner:
Minutes
Calendar jear
Month
Day
Confirm each entry with the „SET“ button.
After the last confirmation with „SET“ the system returns
automatically to the normal display.
1.1. Prolonging the heating phase (party function)
If necessary, you can extend or activate the comfort temperature – the
so-called party function. This extension applies only once. After the
extension has expired, the set time program is executed as usual.
L Note!
You can extend or activate the heating phase by up to four hours. This
extension can furthermore be repeated as often as wished.
Press the “ button.
The comfort temperature is extended by 1 hour whenever the button
is pressed - counting is started from the time the button is pressed.
The period for which the party function is set flashes at the lower
display margin.
The display returns to the normal display when no button is pressed for a
few seconds. The period for which the party function is set flashes at the
lower display margin.
Terminating the party function
You can terminate the party function as follows:
Press the „Prog“, button in order to terminate the party function.
The Timer Thermostat returns to the normal time program.
1.2. Changing over to the lowering temperature (economy
button)
You can change over to the lowering temperature for brief or long-term
periods of absence by means of the economy button.
3