Jung TRDLS-DISPWW Handleiding

Jung Thermostaat TRDLS-DISPWW

Lees hieronder de πŸ“– handleiding in het Nederlandse voor Jung TRDLS-DISPWW (4 pagina's) in de categorie Thermostaat. Deze handleiding was nuttig voor 19 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/4
Standard room temperature controller with display
Art. No.: TR D .. 231 ..
Safety instructions
The unit may only be opened by an electrician
and installed according to the circuit
diagram on the unit or in these instructions.
Observe existing safety instructions.
To satisfy the requirements of protection class II,
corresponding installation measures are required.
This independently-mountable electronic device
is exclusively for controlling the temperature in
dry, enclosed rooms with normal surroundings.
This device conforms with EN 60730 and
functions according to operating mode 1C.
Damage to the device, re or other hazards may
arise if these instructions are not followed.
These instructions are a component part of the
product and must remain with the end customer.
Structure of the device
(2)
(3)
(1)
(4)
(5)
(6)
(7)
Fig. 1: Layout of the temperature controller
(1) Controls
(2) Display
(3) Control buttons
(4) Plug-in contacts
(5) Design frame (not including delivery)
(6) Socket for the plug-in contacts
(7) Use
Function
Correct use
– Measuring and controlling the room temperature
– Measuring and controlling the oor temperature
– Room temperature control via oor heating with
a limiting function (for example in conjunction
with tiled stoves)
– Can be used for "heating only" or "cooling only"
– Installable in a box in conformance with
DIN 49073
– Only for use in dry, enclosed rooms
Product characteristics
– Large display with backlighting
– Text display for self-explanatory operation
– Di󰀨erent user languages can be selected
– Internal temperature sensor
– An external remote sensor can be connected
– ECO input [clock] for the activation of a freely-
settable temperature, e.g. for night reduction
– Time limit for the manually-selected temperature
– Simply switch between 2 temperatures (comfort,
reduction)
– Short-time timer ("party function")
– Frost protection function
– Display of energy consumption for electric
heating systems
– Pulse width modulation (PWM) or two-point
control system
– Adjustable cycle time (PWM), hysteresis and
minimum on/o󰀨 time (two-point)
– Switch on delay, such as for burners (with two-
point control)
– Adaptation to valves normally open or closed
– Valve protection (as a room temperature
controller with and without a limiting function)
– Resetting separate from user and installer
settings
Description of functions
The temperature controller controls the room
or oor temperature according to the set target
temperature and is equipped with an internal sensor
for measuring the room temperature. In addition,
an external remote sensor can be connected,
for example to measure the oor temperature.
The temperature controller compares the measured
temperature with set values. If the temperature falls
below the current setting, the heating system is
turned on.
Two temperature values, T+ and T-, can be preset
(comfort and reduction temperature), between which
it is possible to switch at the touch of a button.
Optionally, an external switch (e.g. a timer) can
be used to control the temperature automatically
to another preset ECO value.
The depends on the type of heating control method
and is determined by the installer:
–Room temperature controller: The heating
is turned on when the room temperature
falls below the set target temperature
(measured with an internal sensor or external
remote sensor).
–Floor temperature controller: The underoor
heating is turned on when the oor temperature
falls below the set target temperature
(measured using an external remote sensor).
–Room temperature controller with a limiter:
(in conjunction with underoor heating):
The room temperature is measured
and regulated using the internal sensor.
An additional external remote sensor is
connected to measure the oor temperature,
and a target temperature range for the oor
is set. The room temperature control is
deactivated when the oor temperature is
outside of this range. If temperature falls below
this range, the heater is turned on, and if the
temperature is above this range, the heater
is turned o󰀨 independent of the current room
temperature.
Operation
(9)
(11)
(12)
(13)(14)(15)
(16)
(8)
(9)
(11)
(12)
(13)(14)(15)(16)
(8)
Fig. 2: Default display
(8) Function display (such as the mode)
(9) Large display (such as the current temperature)
(10) –
(11) Heating mode display
(12) Display (e.g. target temperature)
(13) ξ™š button (OK, switchover T+/Tβˆ’/ECO)
(14) ξ™˜ button
(15) ξ™™ button
(16) ξ™› button (menu)
Basic information
Four buttons below the display are used to operate
the temperature controller (Fig. 2, items (13) to (16)).
In the menu, you can activate operating modes
and make settings. If a button is not pressed for
more than three minutes, the unit automatically
switches back to the previous function and the basic
display (Fig. 2).
Operation when the controls are removed
The unit can also be operated when the controls are
removed. The current temperature is not displayed,
the "heating mode" display ashes, and the display
is not illuminated. If a button is not pressed for more
than three minutes, the display goes dark.
Display information on the current mode
ξ˜ƒξ™— To go to the default display when the controls
are removed and the display is dark, press any
button.
β– Press ξ™š in the default display.
Information on the current mode/setting is
displayed.
β– Return to the default display by pressing
ξ™š.
Selecting modes and setting menus
β– Press ξ™› in the default display.
MENU briey appears in the function display (8).
A help text as a marquee appears at the bottom
edge of the display.
β– Use the ξ™˜ /
ξ™™ buttons to switch to the desired
mode/setting.
β– Select the desired mode/setting by pressing
ξ™š.
Another menu opens depending on the
mode/setting.
β– Go back to the last display/setting by
pressing ξ™›.
β– Return to the default display by pressing
ξ™›
several times.
Manually adapting the target temperature
You can always adapt the target temperature in
modes CONTROL and TIMER.
β– In the default display, press
ξ™˜ξ˜ƒorξ˜ƒξ™™.
The current target temperature ashes.
β– Set the desired temperature by pressing
ξ™˜ /
ξ™™.
β– Accept the displayed temperature by pressing
ξ™š
.
The device returns to the default display.
Turning o󰀨 the control
β– In the default display, press the
ξ™› button for
10 seconds.
First "MENU" appears in the display.
After 10 seconds, the device switches to the
default display and "OFF" appears.
β– Turn the controls back on by selecting a mode.
Main menu
Modes and setting menus (overview 1)
To follow is an overview of the modes and setting
menus within the main menu.
CONTROL
Control of the temperature to the value set here:
T+ = Comfort temperature
Tβˆ’ = Reduction temperature
ECO = When the ECO function is active, the preset
temperature or that set here.
T* = Temperature changed with ξ™˜ /
ξ™™
TIMER
Short-time timer to specify the room temperature
for a set number of hours ("Party function").
β– Press ξ™˜ /
ξ™™ to set the hours and conrm
with ξ™š.
β– Press
ξ™˜ /
ξ™™ to set the temperature and
conrm with ξ™š.
The display (12) shows the number of
remaining hours.
On exiting, that mode is continued which was
active before TIMER. TIMER continues when
ECO is activated and ECO is delayed accordingly.
Manual exiting of TIMER by selecting the
CONTROL mode.
USER SETTINGS
Open the menu for the user settings.
The display (9) shows the menu ID G1.
β– To select the desired submenu, see "User
settings".
INSTALLER SETTINGS
Open the setting menu for the installer.
The display (8) shows the menu ID H1.
β– To select the desired submenu, see "Installer
settings".
Overview 1: Modes and setting menus
Select the desired mode/setting menu
The device is in the default display.
β– Press the ξ™›ξ˜ƒbutton.
The help text "MENU..." appears at the bottom
edge of the display.
β– Press the buttons ξ™˜ /
ξ™™ until the desired menu
item (mode or setting menu) appears.
β–  Conrm with ξ™š.
The function is activated in modes CONTROL
and TIMER.
With the other menu items, the device jumps to
additional settings (see overview 1).
User settings
Overview 2
A marquee at the bottom of the display shows
information for an individual menu items identied
with G1 to G16.
ξ˜ƒξ™— The menu item G3 is not available and,
depending on the set control procedure,
the menu items G11 and G12 are not available.
(The menu displays and set all values are in
UPPERCASE, and the settings are
bold
)
G1 T+ TEMP
Presetting of the comfort temperature:
– For H1 = ROOM or LIMITER:
OFF, 5.0 Β°C, 5.5 Β°C …
21.0 Β°C
… 30.0 Β°C
– For H1 = FLOOR:
OFF, 10.0 Β°C, 10.5 Β°C …
28.0 Β°C
… 40.0 Β°C
Press ξ™˜ /
ξ™™ to set the temperature and conrm
with ξ™š.
G2 Tβˆ’ TEMP
Presetting of the reduction temperature:
– For H1 = ROOM or LIMITER:
OFF, 5.0 Β°C, 5.5 Β°C …
18.0 Β°C
… 30.0 Β°C
– For H1 = FLOOR:
OFF, 10.0 Β°C, 10.5 Β°C …
18.0 Β°C
… 40.0 Β°C
Press ξ™˜ /
ξ™™ to set the temperature and conrm
with ξ™š.
G4 OFF HEATING PERMANENT
Turn o󰀨 the temperature control:
– YES = Control o󰀨
–
NO
= Control on
Select YES/NO with ξ™˜ /
ξ™™, conrm with ξ™š.
If OFF HEATING PERMANENT = YES is selected,
the frost protection is active, provided that it has
been set by the installer, see also Installer settings
H6 - FROST PROTECTION β‰  OFF.
Display function (8): OFF
Turn on the control again: Select a function using
the menu, or hold ξ™› for 10 s.
G5 T* MAX LENGTH
The maximum validity period for T* can be set,
e.g. setting to 3 hrs: After 3 hrs, the previously
selected temperature (T+, Tβˆ’, ECO) is used.
–
OFF
, 1 hrs, 2 hrs … 23 hrs
Select the number of hours with
ξ™˜ /
ξ™™,
conrm with ξ™š.
G6 KEY LOCK
Protect the controller against unauthorized use.
Use is not possible when access protection is
enabled.
– access protection onYES =
–
NO
= no access protection
Select YES/NO with ξ™˜ /
ξ™™, conrm with ξ™š.
Remove access protection: Press any button,
and when CODE is displayed, set 93 with
ξ™˜ /
ξ™™
and conrm with ξ™š.
G7 TEMP LIMIT MIN/MAX TEMP
Set the lower and upper temperature to be
controlled:
– LOWER TEMP LIMIT:
For room temperature controller
(H1 = ROOM or LIMITER):
5.0 Β°C
, 5.5 Β°C … 30.0 Β°C
For oor thermostat (H1 = FLOOR):
10.0 Β°C
, 10.5 Β°C … 40.0 Β°C
– UPPER TEMP LIMIT:
For room temperature controller
(H1 = ROOM or LIMITER):
5.0 Β°C, 5.5 Β°C …
30.0 Β°C
For oor thermostat (H1 = FLOOR):
10.0 Β°C, 10.5 Β°C …
40.0 Β°C
Set the temperatures with
ξ™˜ /
ξ™™ and conrm with ξ™š.
In CONTROL mode, the temperature range is
limited to the values set here.
G8 COSTS/HR OF ENERGY
Enter the estimated energy costs per hour for the
room in which the temperature is being controlled:
1, 2, ...
100
... 999 CENT/HR
ξ˜ƒξ™— If the energy cost meter is to serve
as an operating hour meter, set the value
COST/HR to 100.
Set COST/HR with ξ™˜ /
ξ™™, conrm with ξ™š.
The determined consumption is displayed
under G9.
G9 ENERGY CONSUMPTION TO DATE
Display of the approximate energy consumption
in euros (or operating hours) per time period.
The current day is included up to the displayed time.
Calculation: Time heat turned on x COST/HR (G8).
EURO/2DAYS, EURO/WEEK, EURO/30DAYS,
EURO/YEAR.
Select the period for calculating the energy
consumption, display it with
ξ™˜ /
ξ™™, go back to the
menu with ξ™š.
Reset using INSTALLER SETTINGS (H9)
G10 DISPLAY TARGET TEMP
Setting for the target temperature to be shown in
the display instead of the current room temperature:
– Target temperatureYES =
–
NO
= Room temperature
Select YES/NO with ξ™˜ /
ξ™™, conrm with ξ™š.
G11 ADJUST TEMP
ξ˜ƒξ™— This menu item is not available when used as
a oor temperature controller.
Specify a correction value to be displayed and
regulated:
-5.0 Β°C, -4.9 Β°C …
0.0 Β°C
... 4.9 Β°C, 5.0 Β°C
ξ˜ƒξ™— Useful adaptations are for example matching
calibrated thermometers, or adapting to
installation heights or locations that are
problematic.
Adjust the correction value with
ξ™˜ /
ξ™™ and conrm
with ξ™š.
G12 NUMBER FOR FLOOR TEMP
ξ˜ƒξ™— This menu item is not available when used
as a room temperature controller with/without
a limiting function.
Activate the oor temperature display for
information (without the unit Β°C).
– YES = display the oor temperature
–
NO
= display the room temperature
Select YES/NO with ξ™˜ /
ξ™™, conrm with ξ™š.
G13 BACKLIGHT
Set the display lighting:
–
SHORT
= short time after pressing the button
– OFF = always o󰀨
– PERMANENT (only when using a remote sensor)
Select SHORT/OFF or PERMANENT with ξ™˜ /
ξ™™,
conrm with ξ™š.
G14 LANGUAGE
Select the language for the texts shown in the
display: GERMAN, ENGLISH, DUTCH, FRENCH,
RUSSIAN, SPANISH, ITALIAN, POLISH, TURKISH
Select the LANGUAGE with ξ™˜ /
ξ™™, conrm
with ξ™š.
G15 INFO
Display controller type and controller version:
TR D ...
Display the controller version with
ξ™˜ / ξ™™, go back
to menu with ξ™› or ξ™š.
G16 RESET USER SETTINGS ONLY
Reset the user settings to the defaults.
ξ˜ƒξ™— The counter ENERGY CONSUMTION TO
DATE is not reset. This is reset by the installer
in the menu H9.
– resetYES =
–
NO
Select YES/NO with ξ™˜ /
ξ™™, conrm with ξ™š.
Overview 2: User settings
ALBRECHT JUNG GMBH & CO. KG
Volmestrasse 1
58579 SchalksmΓΌhle, Germany
Telephone: +49 (0)2355 8060
Fax: +49 (0)2355 806204
kundencenter@jung.de
www.jung.de
Service Centre
Kupferstr. 17-19
44532 LΓΌnen
Germany
Temperature management
EN
Operating and installation instructions
09/2018
0024073402
Open the settings menu and make settings
The display shows the menu code G1 in the display
(9) and, beneath that, the marquee T+ SET.
β– Press ξ™˜ /
ξ™™ to select the desired menu.
The menu ID and a help text appear at the
bottom edge of the display (8) and (12).
β–  Conrm with ξ™š.
The rst settable value ashes in the display.
β– Set the desired value by pressing
ξ™˜ /
ξ™™.
β–  Conrm with ξ™š.
The next settable value ashes in the display.
Once all the values are set, the display returns
to the higher level and displays the menu ID.
Start-up
ξ˜ƒξ™– CAUTION!
The heating system will malfunction
if the controls are incorrectly set.
This can damage the heating system.
Only a technician may adjust the settings
of the heating system.
Set the heating mode when starting the controller.
β– Press ξ™› in the default display.
MENU briey appears in the function display (8).
A help text as a marquee appears at the bottom
edge of the display.
β– Press the ξ™˜ /
ξ™™ buttons until INSTALLER
SETTINGS appears.
β–  Select INSTALLER SETTINGS with
ξ™š.
CODE is displayed, and code number 0 ashes.
β–  Select code 7 with ξ™˜ /
ξ™™, conrm with ξ™š.
H1 and the marquee text HEATING TYPE are
displayed.
β– Press ξ™š.
ROOM
is the default. When switching the heating
mode, all the user and installer settings are reset to
the default.
β– Press ξ™˜ /
ξ™™ to set the desired heating mode
and conrm with ξ™š.
The heating mode is set.
Additional settings are available under "Installer
settings".
Installer settings
Overview 3
A marquee at the bottom of the display shows
information for an individual menu items identied
with H1 to H11.
ξ˜ƒξ™— Some menu items are not available under the
control modes set under H1.
The abbreviations for the relevant control mode for
each menu item are indicated in the table.
The abbreviations have the following meaning:
R = Room temperature controller
F = Floor temperature controller
L = Room temperature controller with a limiting
function
(The menu displays and set all values are in
UPPERCASE, and the )presettings are bold
H1 HEATING TYPE R F L
Selection of the control method depending on the
heating mode:
–
ROOM
= Room temperature controller with
the setting of whether or not a remote sensor is
connected:
EXTERNAL SENSOR = YES/
NO
– FLOOR = Floor temperature controller
– LIMITER = Room temperature controller with
limiter
Select with ξ™˜ /
ξ™™, conrm with ξ™š.
H2 CONTROL MODE R F L
Select the control mode:
–
PWM
= Pulse width modulation with the cycle
time set in minutes:
10
, 15 ... 30.
ξ˜ƒξ™— For fast heating systems, select a short cycle
time, for slow heating systems, select a long
cycle time. The minimum on/o time is 10% of
the cycle time.
– ON/OFF = Two-point control with setting option
of the hysteresis (
OFF
, 0.1 Β°C, 0.2 Β°C … 5.0 Β°C)
and the minimum switch-on/switch-o󰀨 time of the
relay in minutes (1, 2 …
10
... 30).
ξ˜ƒξ™— If the hysteresis is not set, the relay switches
with the minimum on/o time even when the
temperature dierences are very small.
Select with ξ™˜ /
ξ™™, conrm with ξ™š.
H3 MIN/MAX FLOOR TEMP L
Setting the upper and lower limit for the oor
temperature:
– LOWER LIMIT FLOOR TEMP: The oor should
not be colder than the temperature set here
(
OFF
, 10.0 Β°C, 10.5 Β°C … 35.0 Β°C).
– UPPER LIMIT FLOOR TEMP: The oor should
not be warmer than the temperature set here
(OFF, 10.0 Β°C, 10.5 Β°C …
35.0
Β°C
... 40.0 Β°C,
OFF).
Set the temperatures with ξ™˜ /
ξ™™ and conrm with
ξ™š.
ξ˜ƒξ™— To deactivate the upper or lower limit, set the
lower temperature limit < 10Β°C, or the upper
temperature limit > 40Β°C with ξ™˜ /
ξ™™ . OFF is
displayed.
H4 HEATING OR COOLING R
Switching the controller between heating and
cooling mode:
–
HEATING
– COOLING
ξ˜ƒξ™— Precondition for switching to cooling mode:
H2 - CONTROL = ON/OFF
ξ˜ƒξ™— H4 = Heating: If there is an error, heating takes
place for 30 % of the time.
H4 = Cooling: If there is an error, the relay
is o.
ξ˜ƒξ™— When switching to cooling mode, H6 - FROST
PROTECTION is automatically set to OFF,
and H7 - OPTIMUM START is set to NO.
ξ˜ƒξ™— The switching times and temperatures of
heating mode are used.
Select with ξ™˜ /
ξ™™, conrm with ξ™š.
H5 VALVE PROTECTION R L
Protection of the valve from seizing after
long periods with no control. Every 24 hours,
calculated from the last switch-on of the voltage of
RESET (H11), the valve is opened for the time set
here in minutes: OFF, 1, 2,
3
… 10.
Set the opening time with
ξ™˜ /
ξ™™ and conrm with ξ™š.
H6 FROST PROTECTION R F L
Setting the frost protection temperature:
– For H1 = ROOM or LIMITER:
OFF,
5.0 Β°C
, 5.5 Β°C … 30.0 Β°C
– For H1 = FLOOR:
OFF,
10.0 Β°C
, 10.5 Β°C … 40.0 Β°C
Press ξ™˜ /
ξ™™ to set the temperature and conrm
with ξ™š.
If the temperature falls below the set frost protection
temperature, heating is turned on.
ξ˜ƒξ™— To deactivate the frost protection with a button
ξ™™ξ˜ƒselect the OFF setting under the lowest
temperature.
ξ˜ƒξ™— Frost protection mode is only possible when
the control is shut o; see user settings:
G4 - OFF HEATING PERMANENT = YES
H7 ECO SETTING R F L
Presetting of the ECO temperature:
– For H1 = ROOM or LIMITER:
OFF, 5.0 Β°C, 5.5 Β°C …
18.0 Β°C
… 30.0 Β°C
– For H1 = FLOOR:
OFF, 10.0 Β°C, 10.5 Β°C …
18.0 Β°C
… 40.0 Β°C
Press ξ™˜ /
ξ™™ to set the temperature and conrm
with ξ™š.
ξ˜ƒξ™— The temperature set here is only used when
the ECO input is activated (see ...).
H8 VALVES NORMALLY OPEN R L
Reverse of the relay switching behaviour for using
actuators that are normally open:
– activatedYES =
–
NO
= deactivated
Select YES/NO with ξ™˜ /
ξ™™, conrm with ξ™š.
H9 ENERGY COUNTER RESET R F L
Reset to zero the energy cost meter set under
G8/G9 (see user settings).
– resetYES =
–
NO
Select YES/NO with ξ™˜ /
ξ™™, conrm with ξ™š.
H10 FLOOR TEMPERATURE DISPLAY L
Display of the current oor temperature for service
purposes.
H11 RESET ALL R F L
Reset to the defaults all of the settings made in the
menus for the installer and user.
– resetYES =
–
NO
Select YES/NO with ξ™˜ /
ξ™™, conrm with ξ™š.
ξ˜ƒξ™— For safety reasons settings among H1 and the
selected language will not be changed with a
RESET. .
Overview 3: Installer settings
Open the settings menu and make settings
The display shows the menu code H1 in the display
(8) and, beneath that, the marquee HEATING TYPE.
β– Press ξ™˜ / ξ™™ to select the desired menu.
The menu ID and a help text appear at the
bottom edge of the display (7) and (11).
β–  Conrm with
ξ™š.
The rst settable value ashes in the display.
β– Set the desired value by pressing
ξ™˜ /
ξ™™.
β–  Conrm with
ξ™š.
The second settable value ashes.
β– Repeat the aforementioned steps until all the
values are set.
The display returns to higher-level and displays
the menu ID.
Appendix
Do not dispose of this product in household
waste. Dispose of the device in a facility
designated for electronics waste.
Consult the local recycling authorities.
ξ™”This symbol conrms that the product is in
conformance with the relevant guidelines.
Technical data
Operating voltage: AC 230 V ~
Rated frequency: 50 Hz
Output: N/O contact relay, non-oating
Switching current: 10 mA ... 10 (4) A, 230 V~
Power consumption: ~ 1.2 W
Degree of protection: IP 30
Protection class: II (with corresponding installation)
Pollution category: 2
Ambient temperature:
- Operation: 0Β°C to 40 Β°C (without thawing)
- Storage: -20Β°C to 70Β°C (without thawing)
Temperature setting range (in increments of 0.5 Β°C):
- As a room temperature controller: 5Β°C ... 30 Β°C
- as a oor temperature controller: 10Β°C ... 40 Β°C
Temperature display: In increments of 0.1Β°C
Output signal: Pulse width modulation (PWM)
or two-point control ( on/o󰀨)
PWM cycle time: Adjustable (10 ... 30 min)
Hysteresis: Adjustable (with two-point control)
Minimum switching time: Adjustable (1 ... 30 min)
Rated impulse voltage: 4 kV
Temperature for the ball thrust test: 75 Β± 2Β°C
Voltage and current for the EMC
emitted interference test: 230 V, 0.1 A
Software class: A
Accuracy: < 4 min/year
Reserve power: ~ 10 years (lithium cell)
Help in case of problems
Overviews 4 and 5 describe a few error messages
and problems as well as probable causes and
solutions.
Error message/problem
Possible cause
– Suggestions for troubleshooting
Display of device errors
Errors in the hardware conguration can be shown
on the display. In this case, ERR and an error type
are displayed as marquee text.
ERR CONFIGURATION
The controls and insert do not match.
– Only use matching components.
– Turn the power o󰀨 and on.
ERR COMMUNICATION
Communication problem between the controls and
insert.
– Remove the controls and put them back on.
– Turn the power o󰀨 and on.
ERR EXT SENSOR
External remote sensor broken/shorted/missing.
– Check whether the remote sensor is connected.
The limits of the display range are exceeded.
– Determine the cause and eliminate it.
Overview 4: Display of device faults
Other problems and operating errors
The room is heating up too slowly.
The oor temperature is limited by the maximum
limiter.
– Adjust the upper limit (H3).
The room temperature is too hot.
The oor temperature is limited by the minimum
limiter.
– Adjust the lower limit (H3).
No entries can be made.
Access protection is enabled.
– Disable access protection (G6).
The desired temperature cannot be set.
The temperature limitation prevents the desired
setting.
– Adjust the temperature limitation (G7).
The temperature display does not change.
The target temperature display is activated.
– Activate the display of the room temperature (G10).
Overview 5: Other problems and operating errors
Accessories
Remote sensor (not included in the delivery)
The external sensor must meet the requirements of
protection class II.
Please use sensor cable H03VV-F for installation in
protection tube or H05VV-F without protection tube.
Type: FF 7.8
Length: 4 m (can be extended up to 50 m)
Wire: Flexible, nely stranded
Stripped end: 8 mm
Fig. 7: External remote sensor
Resistance/temperature table for remote sensor
FF 7.8
Temperature [Β°C] Resistance [k ]W
10 66.8
20 41.3
25 33
30 26.3
40 17.0
50 11.3
Table 1: Resistance/temperature table for
remote sensor FF 7.8
Warranty
The warranty is provided in accordance with
statutory requirements via the specialist trade.
(7)
(22)
(23)
(21)
Fig. 5: Installation
ξ˜ƒξ™— Only install the temperature controller in non-
conductive plastic ush-mounted boxes with
a diameter of 60 mm!
β– Align the insert (7) in the appliance box (22).
β–  Fix the insert with fastening screws (23).
Install the insert so that the plastic tongue (21)
functions as insulation against the fastening
screw (Fig. 5).
(7)
(5)
(1)
Fig. 6: Mounting the controls
β– Mount the design frame (5) and secure by
attaching the controls (1).
Connecting the remote sensor
A remote sensor can be used instead of the internal
sensor to measure the room temperature. The menu
item H1 can be used to select whether the remote
sensor is to be used.
An external remote sensor is necessary for
the modes "Floor temperature controller" and
"Room temperature controller with limiter".
The remote sensor line carries mains voltage and
can be extended to 50 m with appropriate lines.
In order to prevent signal faults, do not run the
remote sensor line together with power lines. It is
recommendable to run the remote sensor in ducting.
β– Connect the remote sensor according to the
connection diagram (Fig. 4, item (20)).
β–  When inserting and removing the connecting
line using an appropriate tool, press the release
buttons (Fig. 4/7, item (24)).
Connecting an external switch to the ECO input
To control the temperature to a preset value
automatically, it is necessary to connect an external
switch, e.g. a timer.
β– Connect the connecting line of the external
switch according to the connection diagram.
β–  When inserting and removing the connecting
line using an appropriate tool, press the release
button (Fig. 4, item (25)).
Information for electrically
skilled persons
Installation and electrical connection
ξ˜ƒξ™– DANGER!
Electric shock from touching live parts.
Electric shock can be fatal.
Before working on the device,
disconnect the connecting lines and
cover surrounding live parts!
Installation site
The controller should be installed at a location in the
room which is easily accessible for use.
When using the internal temperature sensor,
the chosen installation site should:
– Enable free circulation of air
– Not be in a draft (such as an open window or doors)
– Not be located behind curtains, cabinets, shelves,
etc.
– Not be exposed to direct sunlight
– Not be directly inuenced by sources of heat
– Not be adjacent to external walls
– Be 1.5 m above the oor
Connecting and installing the controller
(7)
(1)
Fig. 3: Remove the controls from the insert
β– Remove the controls (1) from the insert (7).
β– Remove a maximum of 8 mm of the insulation
from the connecting lines.
N
L
230 V~, 50 Hz
(17)
(18)
(20)
(24) (25)
Fig. 4: Connection diagram
(17) Load heating
The connection terminals (18) for mains and
switching current are designed for solid or exible
conductors with cross-sections of 1 to 2.5 mm
2.
β– Connect the controller according to the
connection diagram (Fig. 4).
β– If necessary, connect an external remote sensor
(20) (see "Connecting the external remote
sensor").


Product specificaties

Merk: Jung
Categorie: Thermostaat
Model: TRDLS-DISPWW

Heb je hulp nodig?

Als je hulp nodig hebt met Jung TRDLS-DISPWW stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Thermostaat Jung

Handleiding Thermostaat

Nieuwste handleidingen voor Thermostaat