Modular car alarm CA-02 Fox 1/2 MHJ51103
The CA-02 Fox car alarm is a simple modular car alarm. It is to be installed
in the interior of cars with 12V and a negative ground.
The alarm can be operated by the ignition key, a hidden switch or by the
original remote control for central locking.
The status of the car alarm is indicated by an LED indicator.
The built-in vibration detector has two levels of sensitivity and a digital
filter which provides a high immunity to false alarms. It responds with either
a warning or an alarm trigger or both. The warning mode causes a short siren
chirp in the case of vibration detector activation. In alarm mode the alarm is
triggered if a vibration is followed by another one within 15 sec. If both modes
are activated then the first vibration will cause a short siren chirp and the other
vibration (within 15 sec.) will trigger the alarm.
A built-in current sensor will trigger the alarm if electrical equipment is
switched ON while the CA-02 is armed. The current sensor will be activated
10 minutes after arming. This prevents the cooling fan from triggering the
alarm. The sensor can be disabled to allow the use of additional equipment
(independent heating, fridge etc.)
The functions of the inputs, the ignition key and the additional detectors
depend on the settings used (see setting table below). The alarm is triggered if
any of the alarm inputs is activated while the alarm is armed. The siren output is
activated for 30 sec. A siren can also confirm arming/disarming by short chirps.
A programmable output can control the immobilization relay or activate
additional detectors while the car is armed. A VALET push button can be used
for emergency disarming or for setting the optional alarm functions according to
the individual customer’s needs.
Specifications
Voltage 9 – 15VDC
Current consumption max. 11mA
Working temperature range -40°C to +85°C
Duration of alarm 30 s
SIR output 1.2 A
PGM output 0.2A
Current sensor 10 min. exit delay
Vibration detector 2 levels of sensitivity
Complies with the basic requirements of the ECE Regulation No. 97 and 1995/56/EC
Directive
Hereby, Jablotron Ltd., declares that this CA-02 is in compliance with
the essential requirements and other relevant provisions of ECE
Regulation No. 97.01 and Directive 1995/56/EC.
Original of the conformity assessment can be found at the web page
www.jablotron.com, section Technical support
Note: Although this product does not contain any harmful materials we
suggest you to return the product to the dealer or directly to the producer
after usage.
Terminal board description
Installation
GND black – connect to the original grounding in the car.
ULK/AL3 white-blue – input to control the alarm by the original central
locking. It reacts to connection or disconnection from ground (depending on
setting). The input can be connected directly onto the wire of the servomotor or
to the signal wire called “unlock” on the central locking unit. If the alarm is
controlled by an ignition key (KEY) it will function as a delayed alarm input. It is
not suitable for connection the hood (bonnet) contact!
LCK/AL2 white-black – input to control the alarm by the original central
locking. It reacts to connection or disconnection from ground (depending on
the setting). The input can be connected directly onto the wire of the
servomotor or to the signal wire called “lock” on the central locking unit. If the
alarm is controlled by an ignition key (KEY) it will function as an instant alarm
input. It is not suitable for connection the hood (bonnet) contact!
DOOR grey - door switch input. It reacts to connection or disconnection from
ground
LED indicator black-white – install it on a visible spot on the dashboard.
Connect the other end of this lead to GND.
PGM Output blue-white - programmable output that can control the
immobilization relay or activate additional detectors while the car is armed. The
maximum load is 0.2A switching to GND.
The function of PGM depends on the setting of parameter 4 (see the
setting table below):
- power supply for an additional detector – the output is activated
when the alarm is armed
- immobilization relay activation - copies the status of the ignition
key when the car alarm is disarmed.
SIR yellow – siren output (max. 1,2 A) switching to GND.
+12V red – connect directly to the battery. Check that the installation is done
properly before powering up! Protected by a built-in fuse.
BLK yellow-white – this input is activated by +12V according to its setting to
confirm locking/unlocking of the car by the original remote control, is activated
by the confirmation signal from the turn lights (flashers) or it blocks the current
sensor and the AL3 input.
KEY blue – input (+12V). Be sure, that there is +12V present while the key is
on while starting the engine.
AL1 white – an alarm input with an instant reaction. It reacts to connection or
disconnection from ground.
VALET green – a push button used for emergency disarming, memory
reading and setting the selectable functions.
NC – not used
The LED indicator
The LED indicator shows the status of the car alarm:
OFF - disarmed
ON - exit delay
Regular slow flashing - armed
Regular fast flashing - entry delay
If you can hear three siren chirps while disarming, then an alarm had
been triggered during the last arming. The cause of the alarm is signaled
by the LED indicator while switching the ignition key on. The number of
flashes indicates the alarm input:
1 flash - DOOR
2 flashes – AL1
3 flashes - current sensor
4 flashes - vibration sensor
5 flashes – ignition key (not when the alarm is controlled by KEY)
6 flashes – AL2
7 flashes – AL3
(AL2, AL3 – not when the alarm is controlled by the central locking)
It is also possible to determine the cause of the last two alarms. With
the ignition key on, press the VALET button the LED will flash repeatedly
(10 times) indicating the cause of last alarm. If the VALET button is
pressed once again during indication, the cause of the second-to last
alarm will be indicated (10 times). You can stop indication by switching the
ignition key off.
Maintenance
The device does not require any special maintenance. We recommend
you to check the function of the door, the hood switches and additional
detectors regularly.
Setting
Some parameters can be changed in the setting mode according to the
table below.
To enter the setting mode:
1. Press and hold the VALET button, for between 4 to 6 seconds, and switch
the ignition key on. Entering setting mode is confirmed by two siren chirps.
2. Parameter status is indicated by the LED and can be changed by switching
the ignition key off for less than 3 sec.
3. To select the next parameter, briefly press the VALET button. Each setting
parameter is confirmed by a corresponding number of siren chirps.
4. To exit setting mode without saving changes, switch the ignition key off for
longer than 3 s (two siren chirps will be heard).
5. To exit and save the changes go through all the parameters. A long siren
chirp acts as confirmation.
If parameter 15 is set to yes, then when programming is finished and the
alarm has been disarmed for the first time the interval between the
unlocking signal (ULK) and the flashing of the turn lights (BLK) is read by
the car alarm. Further disarming will only be possible if the interval
between the ULC and BLK signals is the same (tolerance +/- 200ms).
Warning!!! If parameter 15 is set to
yes and the turning lights are
flashing when the car is armed, it
will not be possible to disarm the
alarm by remote central locking.
CA-02 FOX modular car alarm Installation instruction
s
Modular car alarm CA-02 Fox 2/2 MHJ51103
Alarm controlled by remote central locking
The alarm can be armed when the car is locked by remote control and
disarmed when the car is unlocked remotely. The locking (according to the
parameter 14) and unlocking must always be followed by confirmation from
the turn lights. If the car is unlocked by key (no confirmation from the turn
lights) then the alarm will be triggered. To stop the alarm it is necessary to
unlocked remotely using the original remote control.
If you hear four fast siren chirps when arming, it indicates that an
input has been activated (for example a door is not closed properly).
This input will be disabled automatically until it is deactivated.
If you do not enter the car within one minute after disarming, the car
alarm will rearm but not the central locking. REARM can be disabled
by parameter 2.
Alarm - When armed, the car alarm is guarding the door’s contacts
(DOOR), input AL1 (the hood contact or additional detectors can be
connected here) and checking for any manipulation of the ignition key
(KEY). It also reacts to the activation of built-in vibration and current
sensors. When an alarm is triggered, the siren will sound for 30 sec. To
stop the alarm, disarm the alarm by unlocking the doors using the
original remote control.
Emergency disarming
If the remote controller has been lost, it is still possible to disarm the
car alarm using the VALET button. To disarm the alarm, open the door
(the alarm gets triggered), switch the ignition key on and press the
VALET button. Emergency disarming can be disabled by setting
parameter 5 accordingly.
Alarm control by KEY input
In this mode, the car alarm can be controlled by the ignition key or by
a hidden button. Before you exit the car switch the ignition key on and
off twice. The LED diode starts to light permanently and a 30 sec. exit
delay is provided. Exit the car in that time and close all the car doors. At
the end of the exit delay the siren chirps once and the alarm is then
armed. If any of the alarm inputs is active, the siren chirps four times.
This input is bypassed until it is deactivated (e.g. you close the door). If
you open the door, an entrance delay will start which is indicated by a
short siren chirp and the LED will start flashing quickly. The entry delay
is 15 sec. during which it is necessary to disarm the alarm by switching
the ignition key on. The siren chirps twice to confirm disarming of the
alarm. If parameter 2 - REARM is set to yes, it is possible to control the
car alarm by a switch connected to +12V. When you disconnect +12V
from the KEY input, the alarm will be armed in 30 sec. and by
connecting the input KEY to +12V you will disarm the system.
Alarm - The car alarm provides a 15 sec. entrance delay for opening
the door, vibration and current sensor activation and AL3 input. If the
car is not disarmed during the entrance delay, the alarm will be
triggered. The other inputs react to their activation by triggering the
alarm immediately. When an alarm has been triggered, the siren will sound
for 30 sec.
Disabling the current sensor
If input BLK is active when armed, the current sensor is disabled.
Emergency disarming
If it is enabled by parameter 5, it is possible to disarm the alarm
by pressing the VALET button.
Parameter Setting Function
LED on LED off
1. Alarm controlled by ignition key yes inputs LCK/ULK Alarm controlled by KEY or LCK/ULK and BLK inputs
2. Rearm yes
no Rearming in case there is no activation of alarm input within 1 minute after disarming. If
the alarm is controlled by key and set to yes then 0V on KEY=DISARM and +12V on
KEY=ARM
3. LCK/AL2 and ULK/AL3 input
activation grounding disconnection
from GND Setting of inputs logic. The setting is valid for both alarm control modes.
4. PGM output activation IMO Sensor supply The PGM output can be used for immobilization relay control (it copies the status of
the ignition key) or for supplying additional sensors (active when armed).
5. Emergency disarming yes no Enabling emergency disarming by the VALET button.
6. Acoustic signaling yes no If acoustic signaling is disabled there is no siren confirmation of arming and disarming.
Other actions are confirmed normally.
7. Current sensor yes no To permanently disable the current sensor (for a fridge, independent heating etc.)
8. Higher sensitivity of the vibration
sensor no yes To set the sensitivity of the vibration detector.
9. Warning due to vibration yes no A short siren chirp after vibration sensor activation.
10. Alarm due to vibration yes no An alarm is triggered after the second vibration. The second vibration must follow the
first one within 15s.
11. Open door warning yes no Signaling of an active input during arming
12. AL1 input reaction alarm warning Selection of reaction type for input AL1.
13. AL1 input logic grounding GND
disconnection Selection of activation type for input AL1.
14. Confirmation by the turn lights
(flashers) required yes no If yes, then the locking signal must be followed by confirmation from the turn
lights to arm (the confirmation is always required to disarm)
15 ULK and BLK timer yes no If yes is selected, then disarming will only be possible if the interval between the ULC
and BLK signals is the same as in the case of the first interval (tolerance +/-200ms)
Product specificaties
Merk: | Jablotron |
Categorie: | Auto alarm |
Model: | CA-02 |
Heb je hulp nodig?
Als je hulp nodig hebt met Jablotron CA-02 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding Auto alarm Jablotron
20 Maart 2023
20 Maart 2023
20 Maart 2023
20 Maart 2023
20 Maart 2023
20 Maart 2023
20 Maart 2023
Handleiding Auto alarm
- Auto alarm HP
- Auto alarm Audiovox
- Auto alarm Eufab
- Auto alarm Gemini
- Auto alarm GT
- Auto alarm Spy
- Auto alarm Technaxx
- Auto alarm Viper
- Auto alarm Waeco
- Auto alarm Olympia
- Auto alarm Cobra
- Auto alarm Clifford
Nieuwste handleidingen voor Auto alarm
7 Februari 2024
7 Februari 2024
7 Februari 2024
6 September 2023
30 December 2022
15 Januari 2023
25 April 2023
10 Juli 2023
10 Juli 2023
10 Juli 2023