Irritrol CL-100- Handleiding


Lees hieronder de 📖 handleiding in het Nederlandse voor Irritrol CL-100- (24 pagina's) in de categorie Niet gecategoriseerd. Deze handleiding was nuttig voor 49 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/24
Get more done
TM
Introduction
The Irritrol Climate LogicTM wireless weather sensor system
transforms your automatic irrigation control system into
a high-eciency, water resource-management center.
Compatible with remote-ready Irritrol and Toro controllers,
Climate Logic automatically regulates watering duration
corresponding to real-time weather conditions and specic
geographic and local weather prole information provided on
a region-specic Setup Card. In addition, integral rain and
freeze sensing further reduce wasteful, unnecessary irrigation
and icing conditions.
Your Climate Logic system consists of a self-contained,
Weather Sensor/Transmitter that continuously monitors
current air temperature, solar radiation and precipitation.
This data is transmitted at regular intervals throughout the
day to the Receiver Module; linked directly to your controller’s
remote control port. Each day, Climate Logic calculates and
adjusts the programmed station run time duration to the
amount required for the next automatic watering cycle.
The Climate Logic system is designed for easy installation,
setup and use. To take full advantage of the features and
capabilities provided by the Climate Logic system, take a
moment to review the detailed information provided within
this guide.
To answer any questions you may have regarding the Climate
Logic system, or any Irritrol product, please contact an Irritrol
Customer Service representative at 1-800-634-8873.
Climate LogicTM User’s Guide
Wireless Weather Sensor System
Quick Start Guide 2–3 ...................................................................
System Components at a Glance 4–5 .....................................
CL-M1 Receiver Module 4 ..................................................
CL-W1 Wireless Weather Sensor .................................. 5
Climate Logic System Installation 6–11 ...................................
Receiver Module Installation and Setup 6–8 ..................
Weather Sensor Installation and Setup 9–11 ....................
Climate Logic System Operation 12–19 ......................................
Control Feature Setup Options 12 ....................................
Setup Menu Options 13 ........................................................
Utility Menu Options 14 ........................................................
Water Adjust Feature 15 ........................................................
Rain/Freeze Sensor Control Feature 16 ..........................
Water History Review Feature 17 ......................................
Weather Sensor Identication Feature 18 .....................
Control System Synchronization 19 .................................
Remote PIN Setup 19 ..............................................................
Weather Sensor Battery Replacement 20 ...........................
Specications 21 ...........................................................................
FCC Information 22 ......................................................................
2
Climate Logic System Quick-Start Guide
The Quick-Start guide provides the essential steps required to properly install and setup the
Climate Logic system in the most direct route possible. As needed, refer to the detailed information
on the page number listed with each step.
Step 1 – Connect and secure the Receiver Module next
to the controller. See .page 6
Step 2 – Adjust controller program for the A hottest/
driest conditions expected, without causing
over-watering and runo. Retain all watering
time/day restrictions in the program schedule
as required See page .6
Step 3 – Synchronize the Receiver Module and controller
to the current time and date. See page 7.
Step 4 – Insert the Receiver Module as Setup Card
shown. See .page 8
Step 5 – Establish your location by entering the ve-digit
ZIP code, or Lat/Lon coordinates as preferred.
See .page 8
2 Quick Start Setup Guide
MENU
_ _ _ F100%
CLIMATE LOGIC
9:15a11/16
CLIMATE LOGIC
SETUP CARD
CLIMATE LOGIC
SETUP CARD
TM
LOC
ATION
CLIMATE LOGIC
SETUP CARD
CLIMATE LOGIC
SETUP CARD
THIS SIDE UP
Location
LAT
LONG
North America
-000.0000
00.0000
SAVE CANCEL ZIP NEXT
Location
ZIP
00000
CANCEL NEXTLAT
Quick Start Setup Guide 3
Quick-Start Guide
Step 6 – Press and hold the sensor Test Pin for 10–15
seconds to activate the Weather Sensor!
A red LED (viewable through the lower vent
ring) will illuminate twice after 10 seconds to
conrm activation (if not already active).
See . page 9
Step 7 – Press the sensor Test Pin again to conrm
signal reception at the Receiver Module. The
receiver’s red LED will turn on momentarily
when the signal is received. Press the BYPASS
key to cancel the mode delay period Dry-out
and resume normal operation. See .page 9
If the LED does not turn on, refer to the Note:
Weather Sensor setup procedure on . page 19
Step 8 – Check the Rain Sensor threshold setting and
adjust as needed. See page .10
Step 9 – Secure the Weather Sensor to a rain gutter
or other suitable structure that provides
unrestricted exposure. Adjust the sensor
alignment to vertical. See page 11.
CLIMATE LOGIC
52 40%F
Dry Out Remain 12h
MENU
10:15a
BYPASS
11/16


Product specificaties

Merk: Irritrol
Categorie: Niet gecategoriseerd
Model: CL-100-

Heb je hulp nodig?

Als je hulp nodig hebt met Irritrol CL-100- stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Niet gecategoriseerd Irritrol

Handleiding Niet gecategoriseerd

Nieuwste handleidingen voor Niet gecategoriseerd