1. Filter grille
2. Eight Torx-screws
3. Coarse dust filter pad
4. Second filter grille
5. Four plastic clips
1/3
PF40 Coarse Dust Pre-Filter
Accessory Fitting Instructions
1
To gain access to the base of the IQAir device, carefully
lay the IQAir system on the floor. Do not place the
device onto its side arms. To avoid scratching the IQAir
housing, place the device on a soft surface, such as a
towel.
1Insert the filter grille with the holes along the edge into
the base of the IQAir system.
2
Secure the filter grille with the eight Torx-screws and
screw driver supplied with the installation kit. Ensure that
all screws are tight, but be careful not to over-tighten
the screws.
3The PF40 coarse dust filter pad has a rough, cottony side
and a smooth side. Place the filter on top of the filter
grille with the rough, cottony side facing outward. When
properly installed the rough, cottony side will be facing
the floor when the system is in its upright position.
4
Fitting PF40
105.03.00.07 / 11112/3
Accessory Fitting Instructions
To hold the filter pad securely in position, place the
second filter grille over the filter. The metal tabs have
to face outward.
5Secure the filter grille by sliding the supplied plastic clips
into the pre-cut slots in the base of the IQAir system.
6
When all four clips have been fitted, carefully lift the
IQAir device into its upright position again. To replace
the coarse dust filter, simply remove the plastic clips and
the second filter grille to gain access to the filter pad.
7
Fitting PF40
105.03.00.07 / 11113/3
Washing the PF40 filter pad
The filter pad may be washed several times before it
needs to be replaced.
To wash the PF40 filter pad simply take the filter pad
out of the PF40 frame and rinse the pad under cold
water und wipe it gently. Do not use soap or any other
cleaners. Let the pad air dry completely before putting
it back onto your IQAir system.
Accessory Fitting Instructions


Product specificaties

Merk: IQAir
Categorie: Niet gecategoriseerd
Model: PF40

Heb je hulp nodig?

Als je hulp nodig hebt met IQAir PF40 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Niet gecategoriseerd IQAir

Handleiding Niet gecategoriseerd

Nieuwste handleidingen voor Niet gecategoriseerd