WH21
ELECTRIC WATER HEATER TIME SWITCH
SINGLE POLE SINGLE THROW (SPST)
25 AMP (6250 WATT) RESISTIVE, 1500 WAT TUNGSTEN,
2 H.P. (20 FLA/80 LRA) - 208 OR 250 VOLT, 60 HZ.
CAUTION: THIS SINGLE POLE TIMER SWITCH BREAKS ONLY ONE
(HOT) LINE CONNECTED TO THE WATER HEATER. THE OTHER
(HOT) LINE IS UNINTERRUPTED FOR YOUR SAFETY. DISCONNECT
ALL ELECTRIC POWER AT THE MAIN PANEL BEFORE SERVICING
THIS SWITCH OR THE WATER HEATER IT IS CONNECTED TO.
This time switch will repeat a pre-
set schedule daily except when
the EXTERNAL MANUAl PUSH-
BUTTON is used. This manual
button permits the user to turn
the water heater ON and OFF
ahead of the schedule. The Time
Switch will resume the preset
program by the next scheduled
ON OFFor operation. The dia-
gram on the right shows the
mechanism and wiring of this
time switch. The TIME-MARK is
used to line up the correct time-
of-day on the TIME-DIAL. The
ON and OFF TRIPPERS turn the
water heater ON and OFF at the
times indicated by their respec-
tive position on the TIME-DIAL.
•TO SET PROGRAM
1. Grasp time-dial firmly. and remove time-dial completely from PULL
timer.
2. Remove all trippers (silver) and trippers (brass). Use pencil orON OFF
paper clip if necessary.
3. Insert OFF trippers (brass) in slots for desired OFF times, but NOT
CLOSER than 2 hours apart.
4. Insert ON trippers (silver) in slots for desired ON times, but NOT
CLOSER than 2 hours apart. ON and OFF trippers may be spaced
1/2 hour apart from each other.
5. Replace time dial. PUSH IN FIRMLY. If any trippers are near the time-
mark, rotate time-dial to avoid interference with mechanism inside.
6. Turn time-dial CLOCKWISE one or more revolutions until correct time-
of-day is opposite time-mark.
•TO STOP AUTOMATIC OPERATION (But without stopping timer),
PULL outward on time-dial until it clicks.
•TO RESUME AUTOMATIC OPERATION, PUSH inward on dial.
•AFTER POWER FAILURE (or if water heater was disconnected at
main panel) time-dial must be reset to correct time-of-day.
TO SECURE EXTRA TRIPPERS ORDER No. 156T1945A FOR A SET
OF TWO (2) ON AND TWO (2) OFF TRIPPERS.
INTERMATIC INCORPORATED, SPRING GROVE, IL 60081-9698
158WH11638
LR3730
“ON” TRIPPER
(SILVER)
“OFF” TRIPPER
(BRASS)
TIME-DIAL
TERMINAL
BLOCK
INDICATOR
LAMP
TIME
MARK
MANUAL
CONTROL
GROUNDING
SCREW
GRD
LINE 1
LINE 2
GRD
250V
FROM
FUSE
BOX {TO
WATER
HEATER
}
158WH11638 1/5/04 11:41 AM Page 1
hp://waterheatermer.org/Intermac-mers-and-manuals.html#WH21
156EB1945A trippers
hp://waterheatermer.org/How- -troubleshoot-Intermac-WH21-mer.htmlto


Product specificaties

Merk: Intermatic
Categorie: Tijdschakelklok
Model: WH21

Heb je hulp nodig?

Als je hulp nodig hebt met Intermatic WH21 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Tijdschakelklok Intermatic

Handleiding Tijdschakelklok

Nieuwste handleidingen voor Tijdschakelklok