T10000R SERIES
POOL/SPA EQUIPMENT CONTROLS
INSTALLATION
OPERATION &
SERVICE MANUAL
CONTROL PANEL WITH TIME SWITCH FOR INDOOR/OUTDOOR USE
Suitable for Pool Equipment Control and for Direct Connection of Underwater Lights
ELECTRICAL RATINGS: See inside Enclosure Door
Many of today’s energy efficient pools and spas utilize
the advantages of a single electrical panel, containing
all the necessary controls for the safe, efficient and
automatic operation of the pool/spa equipment. In
addition, this Panel can also be used to control any
outdoor equipment, sign or pump within its rated
capacity.
The all-weather enclosure contains none, one or two
heavy-duty, industrial grade Time Switches.
Also, it has provisions to install switches inside
as well as a switch or GFCI receptacle on the outside.
The Time Switch can also accommodate an
optional heater control (fireman) switch.
The Control is designed to operate any pump,
within its rated capacity. However, if protection
to prevent dry start is required by the pump
manufacturer, it must be provided in addition
to this Control. Contact pump manufacturer
if not sure and/or for more details.
DANGER! TO AVOID RISK OF INJURY:
...do not permit children to operate the Control Unit or use the Pool/Spa unless they are closely supervised at all times.
...test GROUND FAULT protection regularly. If it fails to reset, DO NOT USE THE POOL or SPA!
Contact a qualified service technician.
...always disconnect electricity before servicing this control or the equipment connected to it.
READ, FOLLOW AND SAVE THIS INSTRUCTION MANUAL
GENERAL INFORMATION
1
INSTALLATION
1. Remove the four #10 hex head screws from the
back of the enclosure and attach mounting brackets
to enclosure.
2. Select the proper location for the Control and hang
enclosure on a flat vertical surface or other support,
using hardware suitable for the purpose.
3. Prepare the necessary conduit runs, terminate them
at both ends and pull in the conductors as specified
by the installation layout.
4. Refer to Figure 1 below;
note that this enclosure
contains one or two Time
Switch(es). To wire the
panel, follow the wiring diagram located inside the
enclosure door. Make sure that connections to time
switch terminals are tight (25 lb.-in. minimum) and
insulation clears the pressure plate - see illustration.
5. If required by the heater manufacturer, install
fireman switch kit 156T4042A (not furnished)
on Time Switch Plate and make the fireman switch
connections. Use at least #18 AWG wiring with
insulation rated 300 Volt or higher. Place heater
ON/OFF switch on heater to ON (see Figure 2).
Some heaters may require a special connecting
harness, contact heater manufacturer
for details.
6. For direct wiring of underwater lights, the
installation must comply with Article 680-21(b)
of the National Electrical Code or in Canada,
Articles 68-060, -062 and -066.
7. To install additional wiring devices inside the
enclosure, first remove rectangular knock-out(s) in
dead front. Next, remove hex head screws in back
of enclosure and install stand-offs* in place of
screws. Attach wiring device to stand-offs.
Stand-offs are not furnished. Order 21T156A for
a set of four (4) stand-offs and mounting hardware.
8. If external bonding is required, install a bonding
lug at bottom of enclosure and bond installation
according to code requirements.
9. Testing of the installation is optional and recom-
mended only if pump is securely in place and will
not be damaged by this test:
a. Turn the manual lever of the Time Switch to OFF.
b. Turn ON power at breaker panel.
c. Move the manual lever of Time Switch to the
right (ON). Pump should start and run on full speed.
In case of unsatisfactory results, turn OFF power,
check your wiring, refer to Troubleshooting on Page 3.
10. Install front panel over wiring compartment.
The control is now ready for programming,
see OPERATION section on Page 3.
IMPORTANT SAFETY INSTRUCTIONS
When installing and operating this Product and other associated equipment, basic safety precautions should always be followed, including the following:
1. Read and follow all instructions.
2. This Control must be installed by a qualified electrician, according to National and Local Electrical Codes.
3. Install this control not less than 5 feet (3 meters in Canada) from inside edge of pool. USE COPPER CONDUCTORS ONLY.
4. Do not exceed the maximum ratings of individual components, wiring devices, and current carrying capacity of conductors.
5. For Control grounding, bonding, installing and the wiring of underwater lights, refer to Article 680 of the National Electrical Code or Article 68 of the
Canadian Electrical Code.
6. The Control should not operate any equipment which would cause bodily injury or property damage should it be activated unexpectedly.
READ, FOLLOW AND SAVE THIS INSTRUCTION MANUAL
Figure 1
2
OPERATION
TO SET FILTER PUMP TIME SWITCH, follow
instructions on the right. The length of the daily filtration/ heating
cycle depends on many variables such as size, shape, geographic
location of the pool, water chemistry, type of pool equipment,
usage and season of year. If not sure,
contact your local pool service professional for advice.
THE FIREMAN SWITCH (Heater Protection Mechanism), if required,
is factory set and shuts OFF the heater 20
minutes before the Time Switch turns OFF the filter pump. The
Fireman Switch requires no setting or service.
3
TIME SWITCH OPERATING
INSTRUCTIONS
1. TO SET “ON” AND “OFF
TIMES: Hold TRIPPERS against
edge of CLOCK-DIAL, pointing
to time (AM or PM) when ON
and OFF operations are
desired. Tighten tripper screws
firmly.
2. TO SET TIME-OF-DAY:
Pull CLOCK-DIAL outward. Turn in either direction and align
the exact time-of-day on the CLOCK-DIAL (the time now,
when switch is being put into operation) to the pointer.
TO OPERATE SWITCH MANUALLY: Move
MANUAL LEVER below CLOCK-DIAL left or
right as indicated by arrows. This will not affect
the next operation.
FOR MORE THAN ONE DAILY ON-OFF
OPERATION: Place additional tripper pairs on
CLOCK-DIAL (order 156T1978A).
IN CASE OF POWER FAILURE: Reset CLOCK-
DIAL to proper time of day. See step 2 above.
TROUBLESHOOTING
SYMPTOM
1. Time Switch will not keep
time but dial is turning.
2. Time Switch Dial stops
at ON or OFF tripper.
3. Dial stops after switch
turns OFF.
4. Load is ON at all times -
dial is turning.
5. Dead clock motor. (Clock
motor gears do not rotate).
CAUSE(S)
1a. Frequent power outages
1b. Wrong voltage/cycle
1c. Loose clock motor connections
2a. Loose tripper
2b. Bent dial
2c. Defective motor
3a. LINE leads are connected
to LOAD terminals
4a. Welded contacts
4b. Two ON trippers and
no OFF tripper on dial
4c. Defective mechanism
5a. Defective clock motor
(open coil due to lightning or surge)
5b. Loose clock motor connections
5c. Wrong voltage
CORRECTIVE ACTION
Reset dial
Change clock motor
Check connections
Check/change tripper
Check/change mechanism
Change clock motor
Reverse LINE and LOAD con-
nections
Change mechanism
Change tripper
Change mechanism
Change clock motor
Check connections
Change clock motor
Figure 2


Product specificaties

Merk: Intermatic
Categorie: Niet gecategoriseerd
Model: T10000R

Heb je hulp nodig?

Als je hulp nodig hebt met Intermatic T10000R stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Niet gecategoriseerd Intermatic

Handleiding Niet gecategoriseerd

Nieuwste handleidingen voor Niet gecategoriseerd