Operating Instructions
Installation of the appliance may only be carried out by an installer/competent person.
Please ask your installer to instruct you on how to fill and bleed the appliance and the
installation and on their operation. Strictly abide by all the instructions and warnings.
Always use the appliance in accordance with the Operating Instructions. It is forbidden to
interfere with a sealed component.
CONTENTS
1 Operation of the appliance 2
1.1 Operation of the central heating ................................................................. 2
1.2 Operation of domestic hot water supply (in combination with an indirectly
heated hot water storage cylinder ............................................................. 2
2 Operation and display read- 2 out
2.1 Operating mode on the service display 3 ......................................................
2.2 Changing the settings of the various functions ........................................... 3
3 Start- 3 up
4 Faults 4
5 Maintenance 4
© 2014 Intergas Heating Ltd Subject to change.
2
Intergas Heating Ltd is a licensed member of the Benchmark Scheme which aims to improve the standards of installation and commissioning of domestic
heating and hot water systems in the UK and to encourage regular servicing to optimise safety, efficiency and performance. Benchmark is managed and
promoted by the Heating and Hotwater Industry Council. For more information visit www.centralheating.co.uk. Please ensure that the installer has fully
completed the Benchmark Checklist on the inside back pages of the installation instructions supplied with the product and that you have signed it to say that
you have received a full and clear explanation of its operation. The installer is legally required to complete a commissioning checklist as a means of
complying with the appropriate Building Regulations (England and Wales). All Installations must be notified to Local Aerea Building Control either directly or
through a Competent Persons Scheme. A Building Regulations Compliance Certificate will then be issued to the customer who should, on receipt, write the
Notification Number on the Benchmark Checklist. This product should be serviced regularly to optimise its safety, efficiency and performance. The service
engineer should complete the relevant Service Record on the Benchmark Checklist after each service. The Benchmark cheklist may be required in the
event of any warrranty work and as supporting documentation relating to home improvements in the optional documents section of the Home Information
Pack.
1 OPERATION OF THE APPLIANCE
The purpose of the Intergas Compact HRE OV wall mounted gas fired boiler is to heat water and to supply it to the central heating (CH)
system and when an indirectly heated domestic hot water storage cylinder is installed, apply heat to the domestic hot water (DHW)
installation. The Intergas Compact HRE OV boiler is designed for use in open vent systems with a header tank.
The appliance is fitted with a modulating control. This means that the power is adjusted in line with the required heat. The boiler
controller responds to each call for heat from the heating or the DHW system by igniting the burner and monitoring the flame.
1.1 Operation of the central heating
The call for heat arises as a result of the room temperature being lower than the temperature set on the room thermostat. The central
heating temperature control modulates on the basis of the set central heating supply temperature. This means that when the desired CH
supply temperature is approached the appliance adjusts the power. The pump for the CH has a post purge period of 1 minute. The post
purge period may be changed if desired. The pump runs automatically for 10 seconds once every 24 hours to prevent blocking.
1.2 Operation of domestic hot water supply
By connecting the Compact HRE OV to a DHW storage tank the DHW circuit can be heated. The built-in regulation ensures that the
DHW demand takes preference over a CH demand. During delivery of hot tap water no heat is supplied by the appliance to the central
heating system.
2 OPERATION AND DISPLAY READ-OUT
Read-out
Operation
1
On / off
A
On / Off button
2
CH operation or setting maximum CH temperature
B
DHW / CH button, for setting desired temperature
3
DHW operation or setting DHW temperature
C
- button
4
Desired temperature of CH or DHW in °C / Fault code/ Time
D
+ button
5
Clock “on” CH enabled
E
Clock function setting
6
Clock “off” CH disabled
F
DHW comfort function off/eco/on (not applicable for Compact HRE OV)
7
DHW comfort function eco (not applicable for Compact HRE OV)
G
Service button
8
DHW comfort function on ((not applicable for Compact HRE OV)
H
Reset button
9
Operating code
10
Flashes to indicate fault
3
2.1 Operating mode on the service display:
Ventilate
Ignite
CH mode
DHW mode
Heat up appliance on (not applicable for Compact HRE OV)
Note
When the red LED above the reset key flashes a fault has occurred. A fault code will then appear on the temperature/clock display.
2.2 Changing the settings of the various functions
Keeping the key pressed for 2 seconds takes you to the user settings menu (LED at display starts to flash). and the
Then each time you press the key a different function LED will start to flash. The value of the function can be set using the
and keys. The value set is displayed on the display.
The reset key closes the settings menu and stores the changes.
If no key is pressed for 30 seconds, the settings menu is automatically closed and the changes are stored.
The on/off key closes the settings menu without storing the changes.
The button restores the default setting for the switch moments (hold for 5 seconds).
By pressing the or keys the clock can be set and the switch moments can be defined.
By pressing the button 2 time blocks can be programmed in which the CH is on (switch moments 1 to 4).
By pressing the short period. button the new times will be stored in the boiler controller. In the display appears [P] for a
Pressing the button for less than 1 second the following additional functions can be activated:
1. t-on (temporary on), the boiler will respond on every CH demand from the room thermostat until the next switch moment.
2. c-on (continuous on), the boiler will respond on every CH demand from the room thermostat without any time limit.
3. OFF, the boiler will not respond on any CH demand from the room thermostat.
. Can be set between 30°C and 90°C (standard setting 80°C). The maximum CH supply temperature
Low setting for moderately cold weather, high setting for colder weather.
DHW temperature. The temperature in the DHW storage cylinder can be set, if it is connected to an external sensor,
between 40°C and 65°C (standard setting 60°C). To prevent the growth of legionella it is advised not to set the DHW
temperature below 60°C.
All other alterations of settings of the boiler may only be carried out by your installer.
3 START- UP
Once the appliance has been connected to water, gas and electricity supplies and
checked by an authorised installer, the appliance can be started.
Please check the following points:
The heating system feed tank and system must be filled and bled with the manual bleed screws on the radiators.
The appliance must be switched off (Horizontal dash on service display, other LEDs off).
Never switch the appliance on if the appliance, the CH system and heating system feed tank have not been completely
filled and bled.
The room thermostat must be set below the temperature in the room.
The gas tap must be open.
Switch the appliance on with the on/off key in the display (The LED lights up, and the service display goes out).
Set the clock and the switch moments. If the boiler is in a time block that CH is not active the boiler must be set in c-on (see §2.2).
Set the room thermostat higher than the actual room temperature. The appliance will fire for purposes of the CH system.
4 FAULTS
If the following simple appliance faults occur, they can be resolved as follows. In the case of repeated occurrence or other faults
always notify your installer.
1. The CH system does not heat up or does not become sufficiently warm:
Increase the temperature setting at the room thermostat.
Open the radiator valves.
Increase the CH water temperature setting using the key on the operating panel (see §2 and the and ).
Bleed the appliance and installation and check the CH water pressure.
2. The domestic hot water supply does not become hot or hot enough (only when an indirectly heated DHW cylinder
is applied):
Open the domestic hot water tap further.
Set the domestic hot water temperature higher using the key on the operating panel (see §2 and the and ).