Intellinet 562041 Handleiding


Lees hieronder de 📖 handleiding in het Nederlandse voor Intellinet 562041 (16 pagina's) in de categorie Schakelaar. Deze handleiding was nuttig voor 18 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/16
Scan to
register your
product warranty
Important: Read before use. • Importante: Leer antes de usar.
For additional benets:
or go to: register.intellinet-network.com/r/562041
54-Port L3 Fully Managed
PoE+ Switch with 48 Gigabit
Ethernet Ports and 6 SFP+ Uplinks
Instructions Model 562041 (IPS-54M06-10G-850W)
2
This guide presents the basic steps to set up and operate this device.
For the user manual and specifications, visit . Register your product intellinet-network.com
at register.intellinet-network.com/r/562041 or scan the QR code on the cover.
Placement
Prior to use, it is recommended that the switch be placed/positioned:
• on a level surface that can support the weight of the switch
(and any other items that need to be considered);
• with a minimum of 25 mm (approx. 1”) of clearance
on the top and sides for adequate ventilation;
• away from sources of electrical noise: radios, transmitters, broadband amplifiers, etc.;
• where it cannot be affected by excessive moisture;
• within 100 m (approx. 328’) of network devices (RJ45) it’s to be connected to.
• Attach the rubber feet to the bottom of each corner of the switch to increase stability.
The switch includes brackets and screws for optional rack mounting.
1 Disconnect any cables from the switch.
2 Position a bracket over the mounting holes on one side
of the switch and secure it in place with screws.
3 Repeat Step 2 on the other side of the switch.
4 Position the switch in the rack and screw
the brackets to the rack.
5 Reconnect any cables.
Front Panel
All ports on the switch support Auto-MDI/MDI-X functionality, so
you can use straight or crossover UTP/STP cables to connect the
RJ45 ports to PCs, routers, hubs, other switches, etc.
Cat5e/6/6a/8.x UTP/STP cables provide optimal performance; if a status LED doesn’t
English
Instructions
3
English
indicate a link or activity, check the corresponding device for proper setup and operation.
Ports 1 – 48 can provide power to a connected powered device (PoE+ output up
to 30 watts on ports); all powered devices should comply with IEEE 802.3at/af.
LED Color Status Operation
PWR Green On The Switch is connected to a power source
Off The Switch is not connected to a power source
SYS Orange Flashing System is running.
Off System is abnormal or no power
1–48
Link Green
On Port is connected
Flashing Data is transmitted/received
Off No link established.
1–48
PoE Orange On The connected device (PD) is receiving power.
Off The port is not powered or no PD is found
49–54
(SFP) Green
On Valid port connection.
Flashing Data transmitted/received.
Off No link established.
Rear Panel
Chassis Ground Column
Located on the side of the power supply connector, a grounding
terminal connector is used to provide proper grounding for your switch.
It should be wired to an object that provides earth ground.
Power
Use the included power cable to connect the receptacle on the back of
the switch to a power outlet. Then, turn the On/Off switch to On.
WARNING: Avoid turning on the power switch before connecting the power
cable, as it may cause a power surge that could damage the Switch.
Basic Web-Based Browser Management
1 Open your Web browser.
2 http://Enter and the IP address of the switch in the Address field.
The default management IP address is . 192.168.2.1
3 Press to display the login screen. In the Username field, enter ; in the Enter admin
Password field, enter the on the bottom of the switch. Click .serial number OK
Instructions


Product specificaties

Merk: Intellinet
Categorie: Schakelaar
Model: 562041

Heb je hulp nodig?

Als je hulp nodig hebt met Intellinet 562041 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden