Intellihot iQ1001 Gen II Handleiding

Intellihot Ketel & boiler iQ1001 Gen II

Lees hieronder de 📖 handleiding in het Nederlandse voor Intellihot iQ1001 Gen II (80 pagina's) in de categorie Ketel & boiler. Deze handleiding was nuttig voor 61 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/80
Operation & Installation Manual
iQ751, Gen II
1001, Gen IIiQ
iQ1501, Gen II
WARNING
If the information in these instructions is not followed
exactly, a or explosion could result causing re
property damage, personal injury, or death.
Do not store or use gasoline or other ammable
vapors and liquids in the vicinity of this or any
other appliance.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not use
any phone in your building.
Immediately call your gas supplier from a
neighbor’s phone. Follow the gas supplier’s
instructions.
If you cannot reach your gas supplier, call the
re department.
Installation and service must be performed by
a installer, service agency, or the gas qualied
supplier.
Ne pas entreposer ni utiliser d’essence ou
ni d’autres vapeurs ou liquides inammables
à proximité de cet appareil ou de tout autre
appareil.
QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ
Ne pas tenter d’allumer d’appareil.
Ne touchez à aucun interrupteur; ne pas vous
servir des téléphones se trouvant dans
le bâtiment.
Appelez immédiatement votre fournisseur de gaz
depuis un voisin. Suivez les instructions
du fournisseur.
Si vous ne pouvez rejoindre le fournisseur,
appelez le service des incendies.
L’installation et l’entretien doivent être assurés
par un installateur ou un service d’entretien
qualié ou par le fournisseur de gaz.
AVERTISSEMENT
Assurez-vous de bien suivre les instructions données
dans cette notice pour duire au minimum le
risque d’incendie ou d’explosion ou pour éviter tout
dommage matériel, toute blessure ou la mort.
1
Thank you for purchasing this Intellihot unit,
Our journey to create a better heating system began back in the winter of 2005, when a tank-
type water heater brRNHGRZQDQGƠRRGHGP\EDVHPHQW%\FRPELQLng the principles of a diesel
engine’s robustness, robotics intelligence, and marine environment durability, we set out to
design a unit from the ground up ¬that would outperform and outlast all others. Quickly, our goal
grew from not just making a better water heaterEXWFUHDWLQJDQHƝFLHQWDQGLQWHOOLJHQWZDWHU
heating and delivery system.
,QQRYDWLRQLVRXUKDOOPDUNDQGVLPSOLFLW\HƝFLHQF\DQGGXUDELlity are at the core of every
lntellihot product. Our water heaters utilize the best attributes of tank and tankless – with
intelligent logic and integrated recirculation. The result is a water heating system capable
of handling the extreme loads of commercial applications with the preciseness needed for
residential applications.
Our products are proudly engineered and built in GalesburJ,OOLQRLVPDNLQJOQWHOOLKRWWKHƟUVWDQG
RQO\86EDVHGPDQXIDFWXUHURIJDVƟUHGFRQGHQVLQJWDQNOHVVZDWHr heating systems. Over
the past eight years lntellihot has helped commercial customers throughout the nation save
thousands of dollars while eliminating downtime. As we continue to expand our coverage across
North America, we strive to provide you with the same unmatched performance advantages
and savings. Our talented team of dedicated professionals is ready to assist you and help your
business succeed.
I thank you for purchasing our lntellihot products.
Sincerely,
Sridhar Deivasigamani
President, lntellihot Inc.
2
Table of Contents
1. General Information
1.1 Items Shipped With Water Heater. . . . . . . . . . 5
1.2 Serial Number Locations . . . . . . . . . . . . . . . . . 5
2. Safety
2.1 Safety Signal Words. . . . . . . . . . . . . . . . . . . . . 6
2.2 Installation Warnings . . . . . . . . . . . . . . . . . . . . 6
3. Technical Speci cations
3.1 Speci cations Chart . . . . . . . . . . . . . . . . . . . . 8
3.2 High Elevation Installations . . . . . . . . . . . . . . . 8
3.3 Clearance Requirements . . . . . . . . . . . . . . . . . 9
3.4 Connection Speci cations . . . . . . . . . . . . . . . . 9
3.5 Exhaust Gas Standards . . . . . . . . . . . . . . . . . . 9
3.6 Overall Dimensions. . . . . . . . . . . . . . . . . . . . . 10
3.7 Con guration Options . . . . . . . . . . . . . . . . . . 12
4. Quick Reference Installation Guide
4.1 Install the Water Heater. . . . . . . . . . . . . . . . . 13
4.2 Pre-Startup Instructions . . . . . . . . . . . . . . . . 13
5. Preparation Before Installation
5.1 Selecting an Indoor Installation Site . . . . . . . 15
5.2 Selecting an Outdoor Installation Site . . . . . . 16
6. Gas Connection
6.1 Quick Reference Installation Instructions . . . .17
6.2 Fuel Source . . . . . . . . . . . . . . . . . . . . . . . . . . .17
6.3 Gas Pressure Requirements . . . . . . . . . . . . . .17
6.4 Gas Pressure Regulator . . . . . . . . . . . . . . . . . .17
6.4.1 Venting of Gas Supply Regulators . . . .17
6.5 Length of Gas Supply Line. . . . . . . . . . . . . . . 18
6.6 Gas Piping Material . . . . . . . . . . . . . . . . . . . . 18
6.7 Determine Correct Gas Pipe Diameter . . . . . 18
6.8 Gas Pipe Drip Leg and Shut-o Valve . . . . . . 18
6.9 Connecting Gas Line to Unit . . . . . . . . . . . . . 18
6.10 Gas Pipe Sizing Tables . . . . . . . . . . . . . . . . . . 20
7. Air Intake Inlet and Exhaust Gas Outlet
Pipe Connections
7.1 Quick Reference Installation Guide . . . . . . . . 22
7.2 Typical Single Unit Air Intake Inlet and
Exhaust Gas Outlet Pipe Installation . . . . . . . 22
7.3 Two Pipe Vent System (Direct Vent) . . . . . . 24
7.3.1 Single Unit Con gurations . . . . . . . . . 24
7.3.2 Multiple Units Con gurations . . . . . . . 24
7.3.3 Side Wall Air Intake Inlet and Exhaust
Gas Outlet Pipe Termination. . . . . . . . 25
7.3.4 Roof Air Intake Inlet and Exhaust Gas
Outlet Pipe Termination . . . . . . . . . . . 25
7.4 Single Pipe Venting System (Power Vent) . . 26
7.4.1 Single Unit . . . . . . . . . . . . . . . . . . . . . . 26
7.4.2 Multiple Units . . . . . . . . . . . . . . . . . . . 26
7.5 Combustion Air Requirements . . . . . . . . . . . . 27
7.6 Intake Air Inlet and Exhaust Gas Outlet
Pipe Diameter and Length . . . . . . . . . . . . . . 27
7.7 Venting Clearance Speci cations . . . . . . . . . 28
7.8 Exhaust Gas Outlet Pipe Materials . . . . . . . . 29
7.9 Air Intake Inlet Pipe Vent Materials . . . . . . . . 29
7.10 Recommended Exhaust Gas Outlet Pipe
Transitions . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
8. Water Connections
8.1 Quick Reference Installation Instructions . . . 31
8.2 Hot Water Connection . . . . . . . . . . . . . . . . . . 31
8.3 Cold Water Connection . . . . . . . . . . . . . . . . . 32
8.4 Condensate Drain Line. . . . . . . . . . . . . . . . . . 33
9. Electrical Power
9.1 Electrical Recommendations . . . . . . . . . . . . . 3 4
9.2 Connection Instructions. . . . . . . . . . . . . . . . . 34
10. Adjusting CO2 Level
10.1 General Information . . . . . . . . . . . . . . . . . . . . 3 5
10.2 Adjustment Procedure . . . . . . . . . . . . . . . . . . 3 5
11. Natural Gas to Propane Conversion
11.1 General Information . . . . . . . . . . . . . . . . . . . . 39
11.2 Conversion Procedure . . . . . . . . . . . . . . . . . 39
12. Operation
12.1 Control Panel . . . . . . . . . . . . . . . . . . . . . . . . . 4 1
12.2 Turning Water Heater ON and OFF . . . . . . . . 41
12.3 Setting the Time . . . . . . . . . . . . . . . . . . . . . . 4 2
12.4 Adjusting the Water Temperature . . . . . . . . . 42
12.5 Security . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
12.5.1 Setting Passcode Protection . . . . . . . 43
12.5.2 Forgot Passcode . . . . . . . . . . . . . . . . . 43
12.6 iNTouch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
12.7 Life Screen. . . . . . . . . . . . . . . . . . . . . . . . . . . 4 4
12.8 Unit Information . . . . . . . . . . . . . . . . . . . . . . . 44
12.9 More Screens. . . . . . . . . . . . . . . . . . . . . . . . . 45
12.9.1 Wi-Fi . . . . . . . . . . . . . . . . . . . . . . . . . . 45
12.9.2 Error History . . . . . . . . . . . . . . . . . . . . 45
12.9.3 telliCare Service
(Subscribe at Startup) . . . . . . . . . . . . 46
13. Connecting Multiple Units
13.1 General Information . . . . . . . . . . . . . . . . . . . . 4 8
13.2 Installation Procedure . . . . . . . . . . . . . . . . . . 48
13.2.1 telliCare for Multiple Units . . . . . . . . . 50
14. Maintenance
14.1 Side Panel Doors . . . . . . . . . . . . . . . . . . . . . . 51
14.2 Air Filter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
14.2.1 Inspection . . . . . . . . . . . . . . . . . . . . . . 51
14.2.2 Cleaning Procedure . . . . . . . . . . . . . . . 5 1
14.3 Condensate Sediment Cup Cleaning . . . . . . . 5 2
14.4 Maintenance-Free Circulation Pump. . . . . . . 53
14.5 Heat Engine Locations . . . . . . . . . . . . . . . . . . 5 3
15. Wiring Diagrams and Troubleshooting
15.1 Operational Flow Chart . . . . . . . . . . . . . . . . . 54
15.2 Complete Wiring Diagram (all models) . . . . . 55
15.3 Control Board Wiring Diagram
(iQ751 / iQ1001) . . . . . . . . . . . . . . . . . . . . . . . 56
15.4 Control Board Wiring Diagram (iQ1501) . . . . 57
15.5 Troubleshooting Guide . . . . . . . . . . . . . . . . . . 58
1 .
7
7
7
77 Requirements for State of Massachusetts
1 .1 7Notice Before Installation . . . . . . . . . . . . . . . 74
1 .
8
8
8
88 Warranty
1 .1 8Warranty. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75
1 .
9
9
9
99 Product Warranty Card
1 .1 9Warranty Card . . . . . . . . . . . . . . . . . . . . . . . . 78
16. Serviceable Parts . . . . . . .. . . . . . . . . . . . . .. 62
3


Product specificaties

Merk: Intellihot
Categorie: Ketel & boiler
Model: iQ1001 Gen II

Heb je hulp nodig?

Als je hulp nodig hebt met Intellihot iQ1001 Gen II stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Ketel & boiler Intellihot

Handleiding Ketel & boiler

Nieuwste handleidingen voor Ketel & boiler