WIRELESS WEATHER STATION
Ref.: SM121 + SM121-B
- OPERATION INSTRUCTION -
1/ MAIN FUNCTIONS
1. Radio-controlled clock
2. Weather forecast for 4 states: sunny, semi-sunny, cloudy, rainy
3. Seven languages to show the day: English, Germany, French, Italian, Spanish, Dutch, Danish
4. Indoor temperature range: 0°C to 50°C, sampling cycle: 12 seconds
5. Indoor humidity range: 20% to 95%
6. Outdoor temperature/ humidity with RF : up to 3 channels
7. In/out trend indication of temperature/humidity
8. Alarm function for upper or lower limit of outdoor temperature
9. Indication of the comfort index
10. The function of Alarm/ Snooze
11. Summer time
12. Moon phase
2/ POWER-ON AND RESET
2.1 Setting up batteries
a) Open the battery compartment on the back of the station and remove plastic protections of 2 batteries.
b) Place the batteries based polarity, and properly close the door.
c) Then open the door to stack probe back and remove plastic protections of batteries.
d) Place the batteries based on polarity, and properly close the compartment.
e) Then wait for about 7 minutes time is automatically displayed.
Note: for manual tuning, see paragraph 3.3.
2.2 When Power-On and reset, LCD full display for 3 seconds enter the normal state after “Beep” check temperature
and humidity
1. The calendar defaults 0:00 January 1, 2004
2. Alarm defaults 0:00
3. The weather icon defaults semi-sunny
4. Temperature scales defaults Celsius degree °C.
5. Time system defaults 24Hr.
3/ INSTRUCTION OF OPERATING THE KEYS
3.1 Key functions
Six functional keys: DOWN, UP, SET, ALARM, CHANNEL, SNOOZE.
English
SET ALARM
UP
DOWN
SNOOZE
CHANNEL
Click Alarm
On/Off 12hr/24hr
switchable
°C/°F
switchable
Enter into
snooze state
Switchable
between CH1,
2 and 3
Standard
mode Hold Enter into
clock
setting
Enter into
alarm setting Clear current
registere CH
Click Confirm
the setting One step
forward One step
backward
SET Hold 8
steps/second 8 steps/second
backward
Click Confirm the
setting One step
forward One step
backward
ALARM Hold 8
steps/second
forward
8 steps/second
backward
Click One step
forward One step
backward Choose the
channel
ALARM
of
temperature Hold 8
steps/second
forward
8 steps/second
backward
3.2 Normal states
A) Hold “SET” for 2 seconds to enter into time setting
B) Click “ALARM” to switch the alarm on/off
C) Hold “ALARM” for 2 seconds to enter into Alarm setting
D) Press “DOWN” to switch between °C/°F
E) When ALARM rings, click “SNOOZE” to enter into the snooze state every 5 minutes
F) Press “CHANNEL” to switch RF channel, CH1 CH2CH3
G) Hold “CHANNEL” key for 2 seconds to clear out all data of current “CHANNEL”
3.3 Manual time set
1. Hold “SET” key for 2 seconds to enter into time setting
2. The sequence of time setting: Year(2000-2099) Month Date Language Hour Minute Time zone Exit
3. The figures will flash during the setting.
4. Press “SET” to confirm the setting, and enter the next setting state
5. Press “UP” one time, the setting will go ahead for one step; hold the key for 2 seconds, it will run forward by 8
steps/second.
6. Press “DOWN” one time, the setting will backward for one step; hold for 2 seconds, it will run back by 8 steps/second.
7. Moon phase is changed accordingly
8. The system will exit automatically if no key is operated in 8 seconds.
3.4 Alarm set
A) Hold “ALARM” key for 2 second to enter into alarm setting
B) The sequence of alarm setting: Hour Minute exit
C) The figures will flash during the setting.
D) Press “ALARM” to confirm the setting, and enter the next setting state
E) Press “UP” one time, the setting will go ahead for one step; hold the keys for 2 seconds, it will run forward by
8 steps/seconds.
F) Press “DOWN” one time, the setting will backward for one step; hold for 2 seconds, it will run back by 8 steps/second.
G) The system will exit automatically if no key is operated in 8 seconds.
4/ FUNCTION AND EFFECT
4.1 The receiving function of RF
A) After installing the battery and checking temperature/humidity, it will enter RF receiving state automatically for 3 minutes.
B) Under normal display mode, hold the “CHANNEL” key for 2 seconds to clear out the channel information
C) If there is no effective signal with same ID code received for the current channel in 35 minutes, the temperature of
that CH will shows “--.-“.
D) The temperature display will resume back when the correct signal is received again
FONCTION
OPERATION
4.2 The function of alarm
A) The BUZZER will ring for 2 seconds as below:
a. 0 – 10 sec.: 1 “beep” for second
b. 10 – 20 sec.: 2 “beep” for second
c. 20 – 30 sec.: 4 “beep” for second
d. after 30 sec.: “beep” continuously
B) When ringing, click “SNOOZE” key once to enter into 5 minutes snooze states, exit if any other key is clicked.
C) Under snooze state, it will start ringing again if another alarm time is due.
4.3 RCC receiving function
1. How to enter RCC receiving status:
a. It will enter RCC receiving state automatically 3 minutes after powering ON or resetting.
b. It enters RCC receiving automatically at 2:00, 3:00, 4:00, 5:00 everyday.
c. Press “DOWN” key for 2 seconds to enter RCC receiving status forcibly.
2. RCC receiving time is 7 minutes.
3. When it is receiving signals, press “DOWN” key will exit RCC receiving status, pressing any other key will have no
effect.
4. When DST is able and is receiving the signal, it will display the symbol of sun on the LCD, showing that it enters the DST
system, and the time will be 1 hour faster.
5. When the RCC symbols display fully, the relative RCC icon will be OFF if the present time is changed.
4.4 The function of temperature and humidity
A) The indoor temperature range: 0°C to +50°C (32°F to +122°F)
B) The humidity range: 20% to 95%
C) The outdoor temperature range: - 50°C to +70°C (-58°F to +158°F)
D) Sampling period: 12 seconds.
E) The accuracy of temperature: +/- 1°C
F) The temperature and hygrometer sampling will be held when the alarm is ringing
4.5 The function of weather forecast
The weather icons for 4 states: sunny semi-sunny cloudy rainy
DETAILS AND PRECAUTIONS ON THE USE OF BATTERIES :
- Discard a used battery in nature or garbage pollutes and prevents the recovery of recyclable materials.
It is therefore important to limit consumption of batteries and follow these guidelines:
focus on alkaline batteries (that last longer than the saline batteries) and when possible, rechargeable
batteries
deposit batteries and accumulators in specific containers arranged among traders.
For example, metals will be valued and polluted the environment because they contain heavy metals
hazardous to health and the environment primarily (cadmium and nickel)
- The piles must installation by respecting the polarity indicated on the apparatus and the pile.
An incorrect positioning can is to damage the apparatus, is to cause escapes on the level of the pile, is to the extreme to cause a fire or the
explosion of the pile.
- To ensure proper operation, the batteries must be in good condition. In case of abnormality in the functioning of the device, put fresh
batteries
- Never attempt to recharge non-rechargeable batteries. They could run, warm up, causing a fire or explosion.
- Replace all batteries at the same time. Never mix zinc batteries with alkaline batteries or rechargeable batteries
- The batteries must be removed from the device
- Also, remove the batteries from your device if you do not use it for a long time, if the batteries may leak and cause damage.
- Never try to short-circuit the battery terminals
- Never dispose of batteries in fire, they might explode
- Charging of batteries is to be performed by an adult.
- Remove batteries from the device before reloading.
- We recommend an adult to supervise children when they change the batteries so that these instructions are complied with or to make
himself the replacement of batteries.
- If a battery is swallowed, immediately consult a doctor or poison control center nearest you.
Do not forget to carry the product with you
Product specificaties
Merk: | Inovalley |
Categorie: | Weerstation |
Model: | SM121 |
Kleur van het product: | Zwart |
Ingebouwd display: | Ja |
Meeteenheid temperatuur: | F, °C |
Alarm functie: | Ja |
Beeldscherm, aantal kleuren: | Monochroom |
Klok functie: | Ja |
Meetfuncties: | Indoor hygrometer, Indoor thermometer, Outdoor thermometer |
Meetfuncties trend display: | Hygrometer, Thermometer |
weerstation extremum data: | Thermometer |
Weersvoorspelling: | Ja |
Maanfase: | Ja |
Heb je hulp nodig?
Als je hulp nodig hebt met Inovalley SM121 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding Weerstation Inovalley
24 Februari 2023
24 Februari 2023
Handleiding Weerstation
- Weerstation Braun
- Weerstation Daewoo
- Weerstation Honeywell
- Weerstation Ade
- Weerstation Adler
- Weerstation Alecto
- Weerstation Ascot
- Weerstation Auriol
- Weerstation Balance
- Weerstation Balance Meteo
- Weerstation Beurer
- Weerstation Blaupunkt
- Weerstation Brandson
- Weerstation Bresser
- Weerstation Brigmton
- Weerstation Daikin
- Weerstation Davis
- Weerstation Denver
- Weerstation Dexford
- Weerstation Digi-tech
- Weerstation DMV Electronics
- Weerstation Durabase
- Weerstation Ea2 LABS
- Weerstation Elgato
- Weerstation Elro
- Weerstation ELV
- Weerstation EQ-3
- Weerstation Eurochron
- Weerstation Extech
- Weerstation Fluke
- Weerstation Garni
- Weerstation Gira
- Weerstation GlobalTronics
- Weerstation Guardo
- Weerstation Hama
- Weerstation Hesdo
- Weerstation HomeMatic
- Weerstation Hyundai
- Weerstation Irox
- Weerstation IT
- Weerstation Konig
- Weerstation Krontaler
- Weerstation La Crosse
- Weerstation Lexibook
- Weerstation Livoo
- Weerstation Lowrance
- Weerstation Marquant
- Weerstation Meade
- Weerstation Mebus
- Weerstation Medisana
- Weerstation Minox
- Weerstation Muse
- Weerstation Nasa
- Weerstation National Geographic
- Weerstation Nedis
- Weerstation Netatmo
- Weerstation Nor-tec
- Weerstation Paget Trading
- Weerstation PCE Instruments
- Weerstation Perel
- Weerstation Prestigio
- Weerstation Profile
- Weerstation Pyle
- Weerstation Renkforce
- Weerstation Rocktrail
- Weerstation Saphir
- Weerstation Saxon
- Weerstation Sempre
- Weerstation Sencor
- Weerstation Soehnle
- Weerstation Solar
- Weerstation Tanita
- Weerstation Taylor
- Weerstation Techno Line
- Weerstation Technoline
- Weerstation Telefunken
- Weerstation TFA
- Weerstation Theben
- Weerstation Thierry Mugler
- Weerstation Thomson
- Weerstation Unitec
- Weerstation UPM
- Weerstation Velleman
- Weerstation Ventus
- Weerstation Vitek
- Weerstation Weinberger
- Weerstation Xeecom ApS
- Weerstation Ytora
- Weerstation Jacob Jensen
- Weerstation Jung
- Weerstation Optex
- Weerstation Oregon Scientific
- Weerstation Orion
- Weerstation Otio
- Weerstation Clas Ohlson
- Weerstation Camry
- Weerstation Clatronic
- Weerstation ECG
- Weerstation OBH Nordica
- Weerstation GoGEN
- Weerstation EMOS
- Weerstation Cotech
- Weerstation Levenhuk
- Weerstation Cresta
- Weerstation Avidsen
- Weerstation Majestic
- Weerstation Prologue
- Weerstation Trevi
- Weerstation Day
- Weerstation Kemot
- Weerstation Chacon
- Weerstation AcuRite
- Weerstation Buienradar
- Weerstation La Crosse Technology
- Weerstation EVE
- Weerstation Waldbeck
- Weerstation EQ3
- Weerstation Homematic IP
- Weerstation EMOS SELECT
- Weerstation Uzoli
- Weerstation TFA Dostmann
- Weerstation Greisinger
- Weerstation Ease Electronicz
- Weerstation Rebel
- Weerstation PeakTech
- Weerstation YONO
- Weerstation JDC
- Weerstation Greenure
- Weerstation Chauvin Arnoux
- Weerstation ChiliTec
- Weerstation Global Water
- Weerstation Marathon
- Weerstation Gewiss
- Weerstation Browin
- Weerstation ClimeMET
- Weerstation Baldr
- Weerstation Setti+
- Weerstation Bearware
Nieuwste handleidingen voor Weerstation
19 November 2024
19 November 2024
19 November 2024
19 November 2024
18 November 2024
18 November 2024
18 November 2024
18 November 2024
18 November 2024
18 November 2024