Infresco Dimmer 6Kw Handleiding
Infresco
Temperatuurregeling
Dimmer 6Kw
Lees hieronder de π handleiding in het Nederlandse voor Infresco Dimmer 6Kw (2 pagina's) in de categorie Temperatuurregeling. Deze handleiding was nuttig voor 13 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld
Pagina 1/2
Specificati
o
Infresco M
a
Mains Volt
a
Max load a
t
Power Con
s
PIR Set Ti
m
Temperatu
r
Factory Se
t
IP Rating
Gland Dia
m
2 Lamp Ins
t
Operating
T
IP Rating
Max Unit O
p
Dimension
s
PIR Move
m
Operating
V
Direction
Detect
Outdoor T
e
Dimension
s
WARNING
It is import
a
It is recom
m
heat
dissipation
It is recom
m
reference t
o
qualified/tr
a
These regu
Internation
a
ξ
ξ
ξ
ξ
o
ns
a
in Unit
a
ge
t
20Β°C ambient
s
umption
m
e Period
r
e Set point
t
Temperature trip poi
n
m
eter
t
allation
T
emperature
p
erating Temperature
s
m
ent Sensor (option
a
V
oltage
e
mperature Sensor
(
s
a
nt that the Infresco I
R
m
ended that the heats
m
ended that installatio
o
the current edition o
f
a
ined personnel.
lations contain import
a
a
l Standards refer to I.
230
V
6 kW
50m
A
5 Mi
n
5Β°C t
o
n
t 20Β°C
65
Max
C
Must
-20Β°
C
IP65
65Β°C
W=2
8
βDβ in
c
a
l)
12V
d
90Β°A
d
18 M
e
(
optional)
W=1
1
R
is not mounted direc
t
ink be spaced off any
n and maintenance o
f
f
the I.E.E. wiring reg
u
a
nt requirements reg
a
E.C/ directive IEC95
0
V
ac +/-10% 50 Hz
A
n
utes
o
25Β°C
C
able Entry 2.5mmΒ²
be fitted in Parallel
C
to 30Β°C
8
0mm D=200mm H=
8
c
lusive of Glands
d
c
d
justable
e
tres
1
5mm D=110mm H=
5
t
ly to any flammable
m
the mounting wall usi
f
this equipment shou
l
u
lations (BS7671) by
s
a
rding safety of electri
c
0
).
8
0mm
5
5mm
m
aterial i.e. wood.
ng pillars to aid in
d be done with
s
uitably
c
al equipment (for
INFRE
S
S
CO
Installa
M
6kW
ξ
tion & U
s
M
anual
IR Cont
r
s
ersβ
r
ol
INTRODUCTION
The Infresco has been designed specifically to work with Infra Red Heaters, with a rating of 4kW it
will allow you to control a variety of heating and lighting solution.
The Infresco has a 1 to 10 step setting allowing you to find the optimum comfort setting in you
specific area. With energy saving a major factor in the design brief, once the Infresco is switched
on it will automatically manage the heating system. With a built in temperature sensor only
allowing the unit to switch on when required and a PIR that will detects a requirement for the
heater to switch on only when needed. An optional remote control allows for the unit to be fitted
out of the way so safety is paramount. The Infresco has a built in soft start function which will add
up to an additional 30% life to your heater lamp.
APPLICATIONS
Any application were high inrush current is an issue or control is required. Typical use is for Infra Red
Heating lamps, Garden lighting
FEATURES
Soft Start β up to 30% extended life of Lamp
Variable Control β Ability to find comfort level
Simple Installation β Ability to plug directly in 13A Plug with up to 3kW load
Energy Saving β Automated system. (Only heat when required)
Temperature Monitoring β If ambient temperature is above preset the Infresco unit remains
switched off
SAFETY FIRST
Please read these instructions before installing and operating this product. (See warning for
additional information).
Installation
The ideal site for the PIR to be mounted is approximately 2.5 + Meters of the floor. Ceiling
mounting is preferred but not essential
The PIR must not be mounted.
β’ Directly in line of the lamps output
β’ Highly reflective surfaces
β’ Radiators or other thermostatically controlled heaters
β’ Open door ways with people walking past
Commissioning
NOTE: On switch on the PIR takes 60 seconds to set before detection takes place
NOTE: The PIR continues to monitor the area and will reset to the set time every time it detects
movement.
Before testing ensure the wiring is correct. The temperature trip point has already been preset at
the factory. The timer is preset to 5 minutes.
The expected detection area can now be βwalked testedβ using the diagram shown in mind. The
area should be crossed in various directions to ensure coverage is as expected.
Display Features
Display shows βtβ The Infresco is turned OFF as the ambient temperature
is above the trip level set by TEMP. SET.
Display shows βFβ The Infresco is set to FULL output.
Display decimal point pulses The PIR input is waiting to be enabled i.e. no movement.
Display decimal point fully on The Infresco is in Standby mode pressing the remote
control POWER button will toggle the power ON and OFF.
You can check the remote control is transmitting by observing the decimal point flashing rapidly.
ξ
ξ
ξ
ξ
UijthovenξInfraroodξ
Nijverheidstraatξ31ξ
4261ξTKξWijkξenξAalburgξTheξNetherlandsξ
Phone:ξ00ξ31ξ416ξ532724ξ
Fax:ξξ00ξ31ξ416ξ532719ξ
Eβmail:ξinfo@uithoven.nlξ
Web:ξξwww.terrastopper.nlξ
Product specificaties
Merk: | Infresco |
Categorie: | Temperatuurregeling |
Model: | Dimmer 6Kw |
Heb je hulp nodig?
Als je hulp nodig hebt met Infresco Dimmer 6Kw stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding Temperatuurregeling Infresco
18 Juli 2023
18 Juli 2023
Handleiding Temperatuurregeling
- Temperatuurregeling Bosch
- Temperatuurregeling AEG
- Temperatuurregeling ATAG
- Temperatuurregeling Honeywell
- Temperatuurregeling Junkers
- Temperatuurregeling Nefit
- Temperatuurregeling Remeha
- Temperatuurregeling Siemens
- Temperatuurregeling ACV
- Temperatuurregeling Barbecook
- Temperatuurregeling Buderus
- Temperatuurregeling Bulex
- Temperatuurregeling Danfoss
- Temperatuurregeling Elco
- Temperatuurregeling EQ-3
- Temperatuurregeling ICY
- Temperatuurregeling Landis Staefa
- Temperatuurregeling Plugwise
- Temperatuurregeling Sabi
- Temperatuurregeling Samson
- Temperatuurregeling Sentiotec
- Temperatuurregeling Tado
- Temperatuurregeling Thermomax
- Temperatuurregeling Velbus
- Temperatuurregeling Ventus
- Temperatuurregeling Viessmann
- Temperatuurregeling WTH
Nieuwste handleidingen voor Temperatuurregeling
19 December 2024
19 December 2024
30 September 2023
13 Augustus 2023
25 Juli 2023
27 Mei 2023
24 Juli 2023
24 Juli 2023
24 Juli 2023
24 Juli 2023