Horstmann BX2000 Handleiding


Lees hieronder de 📖 handleiding in het Nederlandse voor Horstmann BX2000 (2 pagina's) in de categorie Thermostaat. Deze handleiding was nuttig voor 48 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/2
The Horstmann BX2000 has been designed to provide greater
flexibility to the consumer using Off-Peak electricity for Water
heating. It provides the facility to Boost your Hot water at any
time and to ensure you are automatically connected to the
Off-Peak supply whenever it is available.
FRONT VIEW OF BX2000
INSTALLATION AND CONNECTION SHOULD ONLY BE CARRIED OUT BY A SUITABLY QUALIFIED PERSON
AND IN ACCORDANCE WITH THE CURRENT EDITION OF THE IEE WIRING REGULATIONS.
WARNING : ISOLATE MAINS SUPPLY BEFORE COMMENCING INSTALLATION
BOOST FACILITY 1 or 2 HOUR
Whenever you require additional Hot water out side of an Off-Peak period, simply press either the one
or two hour BOOST button.
NEON INDICATORS
LEAFLET No P80094
ISSUE 3
Press 2 HOUR Boost button for
2 hours of
Hot Water
The BOOST period may be
cancelled at any time by pressing
the CANCEL button
Press 1 HOUR Boost button for
1 hour of
Hot Water
The Boost will automatically switch OFF at the end of the chosen Boost period, ensuring that you use
only the minimum of Standard Rate electricity required to meet your requirements.
Should an Off-Peak supply become available during a Boost period, the BX2000 will automatically
connect to the Off-Peak supply and CANCEL any remaining Boost period.
Pressing either of the Boost button during an Off-Peak period will have no effect. Repeated pressing of
the Boost buttons will not extend the Boost period.
NOTE.
On systems with dual or two separate immersion elements, the Boost supply activates the short or top
element. The Off-Peak rate supply activates the long or bottom element.
The BX2000 has three indicating neons.
The OFF PEAK ACTIVE indicator is illuminated whenever the Off-Peak supply to the immersion heater is
switched ON.
The 1 HOUR or 2 HOUR Boost indicator is illuminated whenever the relevant Boost button is pressed
and the Standard Rate supply to the immersion element is switched ON.
SERVICE AND REPAIR
This programmer is NOT user serviceable. Please do not dismantle the unit.
In the unlikely event of a fault developing please contact a local heating engineer or a qualified
electrician.
ISOLATOR SWITCHES
The BX2000 has two built in double pole isolator switches labelled NORMAL supply and OFF PEAK
supply. When in the OFF position they isolate the relevant supply to the immersion heater and switch
OFF the associated indicator light.
If total isolation of the immersion element(s) is required both switches should be in the OFF position.
For the unit to operate normally both switches should be in the ON position.
Horstmann Controls Limited
Bristol
BS4 1UP
Email: sales@horstmann.co.uk
Website: www.horstmann.co.uk


Product specificaties

Merk: Horstmann
Categorie: Thermostaat
Model: BX2000

Heb je hulp nodig?

Als je hulp nodig hebt met Horstmann BX2000 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Thermostaat Horstmann

Horstmann

Horstmann BX2000 Handleiding

10 Februari 2023
Horstmann

Horstmann HRT3 Handleiding

10 Februari 2023
Horstmann

Horstmann HFT4 Handleiding

10 Februari 2023
Horstmann

Horstmann HTT4 Handleiding

10 Februari 2023
Horstmann

Horstmann HCT2 Handleiding

10 Februari 2023

Handleiding Thermostaat

Nieuwste handleidingen voor Thermostaat