Application
This thermostat is designed to control an electric heating system such as a baseboard
heater, a radiant ceiling, a convector or a fan-forced heater.
The thermostat be used with:CANNOT
• a resistive load under 0.83 A
• a resistive load over 14.6 A
• a system driven by a contactor or a relay (inductive load)
• a central heating system.
WARNING Electrical Shock Hazard.
This thermostat is a line voltage control (120240 Volts). Do not install it if you
are not completely familiar with house wiring. If handled improperly, there is risk
of electric shock hazard, which may cause serious injury or death.
Do you need assistance? We are here to help.
Call 18008312823 for wiring assistance before returning the
thermostat to the store.
2
ATTENTION: MERCURY RECYCLING NOTICE
This product does not contain mercury. However,
this product may replace a product that contains
mercury. Mercury and products containing mercury
should not be discarded in household trash.
For more information on how and where to properly
recycle a thermostat containing mercury in the
United States, please refer to the Thermostat
Recycling Corporation at www.thermostat-recycle.
org.
For mercury thermostat recycling in Canada, please
refer to Switch the Stat at www.switchthestat.ca
N O M E R C U RY
Hg
SUPPLIED PARTS
• One (1) thermostat
• Two (2) 632 mounting screws
• Two (2) solderless connectors
Installation
TURN OFF POWER TO THE HEATING SYSTEM AT THE MAIN
POWER PANEL TO AVOID ELECTRICAL SHOCK.
• All cables and connections must comply with local electrical codes.
• This thermostat has tinned copper wires for line and load connections.
• Special CO/ALR solderless connectors must be used if these wires will be
connected to aluminium conductors.
• Install the thermostat onto an electrical box.
• Install the thermostat about 5 ft. (1.5 m) high, on an inside wall facing the
heater.
• Avoid locations where there are air drafts (such as the top of a staircase or
an air outlet), dead air spots (such as behind a door), or direct sunlight.
• Do not install the thermostat on a wall that conceals chimney or stove
pipes.
• The thermostat wires are not polarized; either wire can be connected to the
load or to the power supply.
CAUTION: ELECTRONIC WASTE NOTICE
The product should not be disposed of with other household waste.
Check for the nearest authorized collection centers or authorized
recyclers. The correct disposal of end-of-life equipment will help
prevent negative consequences for the environment and human
health.
3
Wiring
Connect the thermostat wires to the power and to the load using solderless
connectors for copper wires.
4-wire Installation2-wire Installation
M38834
Thermostat mounting
1. Push the excess wires back inside the electrical
box.
2. Secure the thermostat to the electrical box using
the provided screws.
3. Insert the screws through either the right or left
pair of mounting holes on the thermostat.
NOTE: If there is a protective film or sticker on the
thermostat’s screen, peel it off.
4. Apply power to the heating system. Verify the
installation by checking that the heater can be
turned on by raising the setpoint using the button Up
and off by lowering the setpoint using the button.Down
WARNING
Keep the thermostat’s air vents clean and free
from obstructions.
M38835