APPLICATION
The T8602 Chronotherm® IV Programmable Thermostat
provides electronic control of 24 Vac single-stage heating
and cooling systems or 750 mV heating and 750 mV
cooling. Refer to Table 1 for a general description of the
thermostat. All T8602 Thermostats are powered by
batteries.
MERCURY NOTICE
If this control is replacing a control that contains
mercury in a sealed tube, do not place your old
control in the trash. Dispose of properly.
Contact your local waste management authority
for instructions regarding recycling and the
proper disposal of the old control.
INSTALLATION
When Installing this Product...
1. Read these instructions carefully. Failure to follow
the instructions can damage the product or cause
a hazardous condition.
2. Check the ratings given in the instructions and on
the product to make sure the product is suitable for
your application.
3. Installer must be a trained, experienced service
technician.
4. After completing installation, use these instructions
to check out the product operation.
Location
Install the thermostat about 1.5m (5 ft) above the floor in
an area with good air circulation at average temperature.
See Fig. 1.
Do not install the thermostat where it can be affected by:
— drafts, or dead spots behind doors and in corners.
— hot or cold air from ducts.
— radiant heat from sun or appliances.
— concealed pipes and chimneys.
— unheated (uncooled) areas such as an outside wall
behind the thermostat.
Wallplate Installation
The thermostat can be mounted horizontally on the wall
or on a 50.8 mm x 101.6 mm (2 in. x 4 in.) wiring box.
Position wallplate horizontally on the wall or on a
50.8 mm x 101.6 mm (2 in. x 4 in.) wiring box.
1. Position and level the wallplate (for appearance
only). The thermostat will function properly even
when not level.
2. Use a pencil to mark the mounting holes. See Fig.
2.
3. Remove the wallplate from the wall and drill two
4.76 mm (3/16 in.) holes in the wall (if drywall) as
marked. For firmer material such as plaster, drill
two 5.56 mm (7/32 in.) holes. Gently tap anchors
(provided) into the drilled holes until flush with the
wall.
4. Position the wallplate over the holes, pulling wires
through the wiring opening.
5. Loosely insert the mounting screws into the holes.
6. Tighten mounting screws.
Table 1. Description of T8602 Thermostats.
T8602 System Changeover
System
Selection
Fan
Selection Comments
D Heat-Cool Manual or
Automatic
Selectable
Heat-Off-Cool or
Heat-Off-Cool-Auto
On-Auto System and fan selections are done
by keyboard.
T8602D CHRONOTHERM® IV PROGRAMMABLE THERMOSTATS
69-1510-4 2
Fig. 1. Typical location of thermostat.
Fig. 2. Mounting the wallplate.
WIRING
All wiring must comply with local electrical codes and
ordinances. Refer to Fig. 3 through 6 for typical hookups.
A letter code is located near each terminal for
identification.
CAUTION
Electrical Hazard.
Can cause electrical shock or equipment
damage.
Disconnect power before wiring.
1. Loosen the terminal screws on the wallplate and
connect the system wires. See Fig. 7.
IMPORTANT
Use 18 gauge, color-coded thermostat cable for
proper wiring.
2. Securely tighten each terminal screw.
3. Push excess wire back into the hole.
4. Plug the hole with nonflammable insulation to pre-
vent drafts from affecting the thermostat.
Fig. 3. Typical hookup in heat and cool
system with two transformers.
1.5 METERS
(5 FEET)
YES
NO
NO
NO
M10856
WIRES
THROUGH WALL
WALL
MOUNTING
HOLES
M15044
MOUNTING
SCREWS
WALL
ANCHORS (2)
L1
(HOT
)
L2
M10855
FAN
RELAY
Y G
THERMOSTAT
RC
HEAT
RELAY
RW
L
1
(
HOT)
L
2
COMPRESSOR
CONTACTOR
HEATING
TRANSFORMER
COOLING
TRANSFORMER
2
1 POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD
PROTECTION AS REQUIRED.
JUMPER RC TERMINAL TO R TERMINAL WHEN INSTALLED ON A
ONE TRANSFORMER SYSTEM.
AVAILABLE ON SELECT MODELS. OT WIRES MUST HAVE A
SEPARATE CABLE FROM THE THERMOSTAT CABLE.
2
1
1
3
OTOT
OUTDOOR
TEMPERATURE
SENSOR
3
T8602D CHRONOTHERM® IV PROGRAMMABLE THERMOSTATS
3 69-1510-4
Fig. 4. Typical hookup in heat and cool system with
one transformer.
Fig. 5. Typical hookup in millivoltage heating circuit.
Fig. 6. Typical hookup in millvoltage heating and
24 Vac cooling circuit.
Fig. 7. Correct wiring technique.
Mounting Thermostat
1. Engage tabs at the top of the thermostat and wall-
plate. See Fig. 7.
2. Press lower edge of case to close and latch.
NOTE: To remove the thermostat from the wall, first pull
out at the bottom of the thermostat; remove top
last.
Fig. 8. Mounting thermostat on wallplate.
L1
(HOT
)
L2
M10347A
FAN
RELAY
Y G
THERMOSTAT
HEAT
RELAY
RW
COMPRESSOR
CONTACTOR
TRANSFORMER
B
HEAT
DAMPER
COOL
DAMPER
O
1 POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD
PROTECTION AS REQUIRED.
CAN BE USED FOR CHANGEOVER VALVE ON SINGLE-STAGE HEAT
PUMP SYSTEMS.
AVAILABLE ON SELECT MODELS. OT WIRES MUST HAVE A
SEPARATE CABLE FROM THE THERMOSTAT CABLE.
2
2
2
1
3
OTOT
OUTDOOR
TEMPERATURE
SENSOR
3
RC
W
MILLIVOLT HEATING-ONLY
WALLPLATE
R
M2931
TH
TH/
PP
PP MILLIVOLTAGE
GAS CONTROL
LIMIT
CONTRO
L
M
ILLIVOLTAGE
G
ENERATOR
PILOTSTAT
CONTROL
(IF USED)
M2942
TH
TH/
PP
PP
MILLIVOLTAGE
GAS CONTROL
LIMIT
CONTROL
M
ILLIVOLTAGE
G
ENERATOR
PILOTSTAT
CONTROL
(IF USED)
COOLING
CONTACTOR
W G R RC Y O
L1
(HOT)
L2
1
FAN
RELAY
CHANGEOVER
RELAY
POWER SUPPLY. PROVIDE DISCONNECT MEANS
AND OVERLOAD PROTECTION AS REQUIRED.
1
MILLIVOLT HEATING-24Vac
COOLING WALLPLATE
M482
6
F
OR WRAPAROUND
I
NSERTION STRIP
7
/16 IN. (11 MM).
FOR STRAIGHT INSERTION
STRIP 5/16 IN. (8 MM).
M1462
8
PRESS LOWER
EDGE OF CASE
TO LATCH.
ENGAGE TABS
AT TOP OF
THERMOSTAT
AND WALLPLATE.
A.
B
.


Product specificaties

Merk: Honeywell
Categorie: Thermostaat
Model: Chronotherm IV T8602D

Heb je hulp nodig?

Als je hulp nodig hebt met Honeywell Chronotherm IV T8602D stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Thermostaat Honeywell

Handleiding Thermostaat

Nieuwste handleidingen voor Thermostaat