Do not operate this equipment unless you
have read and understood the contents
of this manual! Failure to follow the
instructions contained in this manual
may result in serious injury or death.
This manual contains important safety
information concerning the maintenance,
use, and operation of this product. If
you’re unable to understand the contents
of this manual, please bring it to the
attention of your supervisor. Keep this
manual in a safe location for future
reference.
English = p 2
WARNING
No opere este equipo al menos que haya
leído y comprendido el contenido de este
manual! Cualquier falla en el seguimiento
de las instrucciones contenidas en
este manual puede resultar en un serio
lesión o muerte. Este manual contiene
importante información sobre seguridad
concerniente al mantenimiento, uso y
operación de este producto. Si usted
no puede entender el contenido de
este manual por favor pregunte a su
supervisor. Almacenar este manual en
una localización segura para la referencia
futura.
ADVERTENCIA
Ne pas utiliser cet équipement sans avoir
lu et compris le contenu de ce manuel ! Le
non-respect des instructions contenues
dans ce manuel peut entraîner de
graves blessures ou la mort. Ce manuel
contient des informations importantes
concernant l’entretien, l’utilisation et le
fonctionnement de ce produit. Si vous ne
comprenez pas le contenu de ce manuel,
veuillez le signaler à votre supérieur.
Conservez ce manuel dans un endroit
sûr pour pouvoir vous y référer plus tard.
Français = p 16
AVERTISSEMENT
Form No. CWBSM-0220 5
English
Model
Compressor
Size Voltage Hertz Watts Amps
Plug
Configuration
Shipping
Weight
CWB-S1 1/5 hp 120 60 300 3.8 NEMA 5-15P 133 lbs. (60 kg)
1/3 hp 220 230 240– – 50 1089–1190–1296 5.0–5.2–5.4 CEE 7/7 Schuko,
BS-1363, AS 3112 133 lbs. (60 kg)
60 1129–1234–1344 5.1–5.4–5.6 CEE 7/7 Schuko, BS-1363
CWB-S2 1/5 hp 120 60 300 3.8 NEMA 5-15P 175 lbs. (79 kg)
1/3 hp 220 230 240– – 50 1089–1190–1296 5.0–5.2–5.4 CEE 7/7 Schuko,
BS-1363, AS 3112 175 lbs. (79 kg)
60 1129–1234–1344 5.1–5.4–5.6 CEE 7/7 Schuko, BS-1363
CWB-S3 1/3 hp 120 60 450 5.9 NEMA 5-15P 213 lbs. (97 kg)
3/8 hp 220 230 240– – 50 826–904–984 3.8–3.9–4.1 CEE 7/7 Schuko,
BS-1363, AS 3112 213 lbs. (97 kg)
1/3 hp 60 1129–1234–1344 5.1–5.4–5.6 CEE 7/7 Schuko, BS-1363
CWB-S4 5/8 hp 120 60 800 8.7 NEMA 5-15P 235 lbs. (107 kg)
1/2 hp 220 230 240– – 50 826–904–984 3.8–3.9–4.1 CEE 7/7 Schuko,
BS-1363, AS 3112 235 lbs. (107 kg)
5/8 hp 60 1956–2138–2328 8.9–9.3–9.7 CEE 7/7 Schuko, BS-1363
MODEL DESIGNATION
SPECIFICATIONS
C W B - S x
Cold Well
Built-In Slim
Full-Size Pan Capacity
Electrical Rating Chart
Plug Configuration
Units are supplied from the factory with an electrical cord and
plug installed. Plugs are supplied according to the application.
WARNING
ELECTRIC SHOCK HAZARD: Plug unit into a properly
grounded electrical receptacle of the correct voltage,
size, and plug configuration. If plug and receptacle do not
match, contact a qualified electrician to determine and
install proper voltage and size electrical receptacle.
NOTE: Receptacle not supplied by Hatco.
NEMA 5-15P CEE 7/7 Schuko
AS 3112
BS-1363
Plug Configuration
Refrigerant Information
All Hatco Slim Refrigerated Drop-In Wells use R-513A
refrigerant in the condensing unit.
NOTE: Shipping weight includes packaging.
The shaded areas contain electrical information for
International models only.
NOTE: The specification labels are located on the bottom of
the unit and the back of the control panel. See the label
for the serial number and verification of unit electrical
information.
6Form No. CWBSM-0220
English
Model
Width
(A)
Depth
(B)
Overall Height
(C)
Well Height
(D)
CWB-S1 27-1/16″
(687 mm)
18-15/16″
(481 mm)
33-1/2″ *
(851 mm)
12-1/16″
(305 mm)
CWB-S2 48-1/8″
(1222 mm)
18-15/16″
(481 mm)
26-1/16″
(661 mm)
12-1/16″
(305 mm)
CWB-S3 68-3/16″
(1757 mm)
18-15/16″
(481 mm)
26-1/16″
(661 mm)
12-1/16″
(305 mm)
CWB-S4 90-1/4″
(2292 mm)
18-15/16″
(481 mm)
26-1/16″
(661 mm)
12-1/16″
(305 mm)
SPECIFICATIONS
D
C
A
Front View
(Model CWB-S4)
Side View
(Model CWB-S4)
B
2-3/4″ (70 mm)
17-3/8″
(441 mm) 9-1/8″
(232 mm)
15-7/16″
(392 mm)
17″ (430 mm)
2-3/4″
(70 mm)
Dimensions
* Subtract 7-1/2″ (190 mm) from Overall Height (C) when control box
is remote-mounted (CWB-S1 model only).
Discharge
Pressure
Suction
Pressure Superheat Subcooling
115 to 125 psig
(7.9 to 8.6 bar)
6 to 9 psig
(0.4 to 0.6 bar)
4° to 10°F
(2.2° to 5.6°C)
5° to 10°F
(2.8° to 5.6°C)
Operating Specifications
NOTE: The Operating Specifications are accurate for units in an ambient
air temperature of 75°F (24°C).
High Side Low Side
186 psig
(12.8 bar)
88 psig
(6.07 bar)
Design Pressure