RT003 START & STOP
BATTERY & ELETRICAL SYSTEM ANALYSER
TEST PROCEDURES / OPERATING INSTRUCTIONS
IMPORTANT:
1.
For testing 6 / 12 volt batteries and 12 / 24 volt charging
systems. (ONLY 12 volt for START & STOP battery test)
2.
Suggested operation range 32℉(0℃) to 122℉(50℃) in
ambient temperature.
1 : Display
2 : Previous/Next keys
3 :ENTER key
1
3
2
GB.2-V1
WARNING:
1.
Working in the vicinity of a lead acid battery is dangerous.
Batteries generate explosive gases during normal battery
operation. For this reason, it is of utmost importance, if
you have any doubt, that each time before using your
tester, you read these instructions very carefully.
2.
To reduce risk of battery explosion, follow these
instructions and those published by the battery
manufacturer and manufacturer of any equipment you
intend to use in the vicinity of the battery. Observe
cautionary markings on these items.
3.
Do not expose the tester to rain or snow.
PERSONAL SAFETY PRECAUTIONS:
1.
Someone should be within range of your voice or close
enough to come to your aid when you work near a lead
acid battery.
2.
Have plenty of fresh water and soap nearby in case
battery acid contacts skin, clothing or eyes.
3.
Wear safety glasses and protective clothing.
4.
If battery acid contacts skin or clothing, wash
immediately with soap and water. If acid enters eye,
immediately flood eye with running cold water for at least
ten minutes and get medical attention immediately.
5.
NEVER smoke or allow a spark or flame in vicinity of
battery or engine.
6.
Be extra cautious to reduce risk of dropping a metal tool
onto the battery. It could spark or short-circuit the battery
or other electrical parts and could cause an explosion.
7.
Remove personal metal items such as rings, bracelets,
necklaces and watches when working with a lead acid
GB.3-V1
battery. It can produce a short circuit current high enough
to weld a ring or the like to metal causing a severe burn.
INSERTION OR REPLACEMRNT OF LEAD WIRE:
1.
Remove the cover in the backside bottom of the battery
tester.
2.
Insert the connectors which contain black-yellow pair and
yellow-red pair in one end of the lead wire into the
sockets which can be found when you remove the cover
as above. Be sure to make colors matched between the
connectors and sockets as shown below.
PREPARING TO TEST:
1.
Be sure area around battery is well ventilated while
battery is being tested.
2.
Clean battery terminals. Be careful to keep corrosion
from coming in contact with eyes.
3.
Inspect the battery for cracked or broken case or cover. If
battery is damaged, do not use tester.
4.
If the battery is not sealed maintenance free, add distilled
water in each cell until battery acid reaches level
specified by the manufacturer. This helps purge
excessive gas from cells. Do not overfill.
Yellow
Black white
Red (Connector)
Yellow (Socket)
Black
White
Red
Connect
(RT003 Backside)