GMH 38 Series
Materialfeuchte material moisture /
H60.0.12.6C-13 Operating Manual GMH 3851 Page 2 22 of
_____________________________________________________ _____________________________________________________________________________
Index
1 GENERAL ADVICE .................................................................................................................................................. 3
2 INTENDED USE ........................................................................................................................................................ 3
2.1 S ................................................................................................................................ 3 AFETY SIGNS AND SYMBOLS
2.2 S I ......................................................................................................................................... 3 AFETY NSTRUCTIONS
3 PRODUCT DESCRIPTION ...................................................................................................................................... 4
3.1 S .............................................................................................................................................. 4 COPE OF DELIVERY
3.2 O M ........................................................................................................................... 4 PERATING AND AINTENANCE
3.3 S .......................................................................................................... 4 TART UP AND READINESS FOR OPERATION
3.4 C ....................................................................................................................................................... 5 ONNECTIONS
3.5 D E .............................................................................................................................................. 5 ISPLAY LEMENTS
3.6 P ....................................................................................................................................................... 5 USHBUTTONS
4 DEVICE CONFIGURATION ................................................................................................................................... 6
5 SOME BASICS OF PRECISION MATERIAL MOISTURE MEASURING ...................................................... 7
5.1 M C W -B M C OISTURE ONTENT AND UET ASIS OISTURE ONTENT W ........................................................................ 7
5.2 S ....................................................................................................................... 7 PECIAL FEATURES OF THE DEVICE
5.3 A -H F ......................................................................................................................................... 7 UTO OLD UNCTION
5.4 A - ('A ........................................................................................... 7 UTOMATIC TEMPERATURE COMPENSATION TC')
5.5 M I W : M W T M -N ............................................................. 8 EASURING N OOD EASURING ITH WO EASURING EEDLES
5.6 S ........................................................................................................................ 8 PLIT LOG FIREWOOD MEASURING
5.6.1 Presettings ...................................................................................................................................................... 8
5.6.2 Sample taking ................................................................................................................................................. 8
5.6.3 Measuring ...................................................................................................................................................... 9
5.7 M O M ........................................................................................................................ 10 EASURING THER ATERIALS
5.7.1 ‘Hard‘ Materials (concrete or similar): Measuring with brush-type probes (GBSL91 or GBSK91) ............ 10
5.7.2 ‘Soft‘ Materials (polystyrene or similar): Measuring with Measuring-rods or -pins ) ........... 10 (GMS 300/91
5.7.3 Measuring bulk cargo, bales and other special measures ........................................................................... 10
5.8 M , .................................................... 10 EASURING OF MATERIALS HAVING NO CHARACTERISTIC CURVES STORED
6 HINTS FOR SPECIAL FUNCTIONS ................................................................................................................... 11
6.1 M ('WET' - OISTURE EVALUATION 'MEDIUM' - 'DRY') ................................................................................... 11
6.2 P - ('S .......................................................................................... 11 RE SELECTION OF FAVOURITE MATERIALS ORT')
6.3 I P C C ............................................................................. 11 NDIVIDUALLY ROGRAMMABLE HARACTERISTIC URVES
7 OPERATION OF LOGGER ................................................................................................................................... 12
7.1 F -S S S UNC TOR“: TORING INGLE EASUREMENTSM ............................................................................................. 12
7.2 - A „FUNC CYCL“: UTOMATIC ECORDING ITH ELECTABLE OGGER YCLE IMER W S L -C -T ..................................... 13
8 OUTPUT ................................................................................................................................................................... 14
8.1 I - B A ('A .') ................................................................................................................. 14 NTERFACE ASE DDRESS DR
8.2 A O S DAC.0 DAC.1 ................................................................................ 14 NALOGUE UTPUT CALING WITH AND
9 APPLICATION IN THE GLUED TIMBER CONSTRUCTION ACC. TO DIN 1052-1 (MPA CERTIFIED) ................................. 14
10 FAULT AND SYSTEM MESSAGES ................................................................................................................. 15
11 INSPECTION OF THE ACCURACY / ADJUSTMENT SERVICES ............................................................ 15
12 MEASURING PRECISION ................................................................................................................................ 15
13 SPECIFICATION ................................................................................................................................................. 16
14 DISPOSAL NOTES .............................................................................................................................................. 16
15 APPENDIX A: SORTS OF WOOD .................................................................................................................... 17
16 APPENDIX B: ADDITIONAL MATERIALS ................................................................................................... 22
16.1 M ............................................................................................................ 22 EASURING OF BUILDING MATERIALS
16.2 M ................................................................................................ 22 EASURING OF AGRICULTURAL BULK CARGO
16.3 E ....................................................................................................... 22 STIMATION OF ADDITIONAL MATERIALS
H60.0.12.6C-13 Operating Manual GMH 3851 Page 3 22 of
_____________________________________________________ _____________________________________________________________________________
1 General advice
Read through this document attentively and make yourself familiar to the operation of the device before you
use it. Keep this document in a ready- -hand way in order to be able to look up in the case of doubt. to
2 Intended use
The device is suitable for the measurement of moisture content and temperature.
The measurement is done using appropriate electrodes and cables. The electrodes are connected via a BNC
or thermocouple connector.
The safety instructions of these operating manual must be followed (see below).
The device may be used only under the conditions and for the uses for which it was designed.
The device must be treated carefully and used according to the technical data (do not throw hit, etc.). ,
Protect against contamination.
2.1 Safety signs and symbols
Warning notices are marked in this manual as shown in table 1:
Warning! Symbol warns of impending danger, death, serious
bodily injury or serious property damage if ignored.
Attention! Symbol warns of potential hazards or hazardous
situations that can cause damage on the equipment or the
environment if ignored.
Note! Symbol indicates incidents that have an indirect impact on
the operation or can trigger an unforeseen reaction if ignored.
table 1
2.2 Safety Instructions
This device has been designed and tested in accordance to the safety regulations for electronic devices.
However, its trouble-free operation and reliability cannot be guaranteed unless the standard safety measures
and special safety advises given in this manual will be adhered to when using it.
1. Trouble-free operation and reliability of the device can only be guaranteed if it is not subjected to any
other climatic conditions than those stated under “Specification”.
Transporting the device from a cold to a warm environment condensation may result in a failure of the
function. In such a case make sure the device temperature has adjusted to the ambient temperature
before trying a new start- up.
2. Whenever there may be a risk whatsoever involved in running it, the device has to be
switched o immediately and to be marked accordingly to avoid re-starting. Operator safety
may be a risk if:
- there is visible damage to the device
- the device is not working as specied
- the device has been stored under unsuitable conditions for a longer time
In case of doubt, please return device to manufacturer for repair or maintenance.
3. Do not use this product as safety or emergency stop device or in any other application
where failure of the product could result in personal injury or material damage.
Failure to comply with these instructions could result in death or serious injury and material
damage.
DANGER
DANGER


Product specificaties

Merk: Greisinger
Categorie: Niet gecategoriseerd
Model: GMH 3851

Heb je hulp nodig?

Als je hulp nodig hebt met Greisinger GMH 3851 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Niet gecategoriseerd Greisinger

Handleiding Niet gecategoriseerd

Nieuwste handleidingen voor Niet gecategoriseerd