Gossen Metrawatt GEOHM PRO Handleiding


Lees hieronder de 📖 handleiding in het Nederlandse voor Gossen Metrawatt GEOHM PRO (49 pagina's) in de categorie Meetapparatuur. Deze handleiding was nuttig voor 55 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/49
Operating Instructions
GEOHM PRO and XTRA
Earth Tester (without/with GPS)
3-349-915-03
2/4.17
2 -I Messtechnik GmbHGMC
Table of Contents
1 Safety............................................................................................................................................... 4
2 Menu ................................................................................................................................................ 5
2.1 Data transmission ......................................................................................................................... 5
2.2 Measurement Settings .................................................................................................................. 5
2.2.1 Line Frequency ............................................................................................................................. 5
2.2.2 Calibrating C-3 Clamp Meters (Z592X) ........................................................................................ 6
2.3 Measuring Instrument Settings ..................................................................................................... 7
2.3.1 LCD Contrast ................................................................................................................................ 7
2.3.2 LCD Illumination ........................................................................................................................... 8
2.3.3 AUTO - OFF Settings ..................................................................................................................... 8
2.3.4 Settings Display ............................................................................................................................ 8
2.3.5 Date and Time .............................................................................................................................. 8
2.3.6 Discharging the Rechargeable Batteries ...................................................................................... 9
2.4 Language Selection ...................................................................................................................... 9
2.5 Information Concerning the Manufacturer .................................................................................... 9
3 Measurements .............................................................................................................................. 10
3.1 Continuity Measurement at Protective Conductors and Equalizing Leads (2-pole) ................... 10
3.2 Calibrating the Measurement Cables ......................................................................................... 11
3.2.1 Activating Automatic Zeroing ...................................................................................................... 11
3.2.2 Deactivating Automatic Zeroing .................................................................................................. 12
3.3 3-Pole Measurement .................................................................................................................. 12
3.4 4-Pole Measurement .................................................................................................................. 15
3.5 3-Pole + Clamp Meter Measurement ......................................................................................... 18
3.6 Measurement with Two Clamp Meters (Z592X/Y) ..................................................................... 21
3.7 4- Pole Measurement (according to the pulse method) ............................................................ 22
3.8 Current Measurement ................................................................................................................. 26
3.9 Measuring Soil Resistivity ........................................................................................................... 27
4 Memory.......................................................................................................................................... 30
4.1 Saving Measurement Results ..................................................................................................... 30
4.2 Clearing Memory ........................................................................................................................ 31
4.3 Scrolling Through the Memory ................................................................................................... 32
5 Data transmission ........................................................................................................................ 33
5.1 Features Package for Working in Combination with a Computer .............................................. 33
5.2 Data Transmission via USB ........................................................................................................ 33
5.3 GPS Settings .............................................................................................................................. 33
6 Measuring Instrument Power Supply ......................................................................................... 34
6.1 Monitoring Supply Voltage .......................................................................................................... 34
6.2 Recharging the Battery Operation with the Charger ............................................................... 34
6.3 Changing the Fuse ..................................................................................................................... 35
6.4 Charging the Batteries ................................................................................................................ 36
6.5 Discharging the Rechargeable Batteries .................................................................................... 37
6.6 General Rules for the Use of Rechargeable Nickel Metal Hydride Batteries (NiMH) ................ 37
-I Messtechnik GmbH 3 GMC
7 Cleaning and Maintenance .......................................................................................................... 38
8 Storage .......................................................................................................................................... 38
9 Dismantling and Disposal............................................................................................................ 38
10 Technical Data .............................................................................................................................. 39
10.1 Primary Technical Data .............................................................................................................. 39
10.2 Additional Data ........................................................................................................................... 41
10.2.1 Influence of Series Interference Voltage on Resistance Measurement for the
- - -Functions 3 Pole, 4 Pole and 3 Pole + Clamp Meters ............................................................... 41
10.2.2 Influence of Series Interference Voltage on Resistance Measurement for the ρ Function ....... 42
10.2.3 Influence of the Auxiliary Electrodes on Earthing Resistance Measurement for
- - -the Functions 3 Pole, 4 Pole and 3 Pole + Clamp Meters ......................................................... 42
10.2.4 Influence of the Auxiliary Electrodes on Earthing Resistance Measurement for the
ρ Function ................................................................................................................................... 42
10.2.5 Influence of the Auxiliary Electrodes on Earthing Resistance Measurement According
to the Pulse Method .................................................................................................................... 42
10.2.6 Influence of Interference Current on the Measurement Results for Earthing
-Resistance, 3 Pole + Current Clamp .......................................................................................... 42
10.2.7 Influence of Interference Current on the Measurement Results for Earth Resistance
with the Help of Two Clamp Meters ............................................................................................ 43
10.2.8 Influence of the Relationship of Resistance Measured with the Clamp Meters
at Branches with Multiple Earthing to the Resultant Resistance (3 pole + clamp meters)- ....... 43
10.2.9 Additional Measuring Uncertainty per IEC 4 (2 61557- - pole)...................................................... 43
10.2.10 Additional Measuring Uncertainty per IEC 61557 5 -
- -(3 pole, 4 pole, 3 clamp meters)-pole + .............................................................................. 43
11 Instrument Reset (default settings) ............................................................................................ 44
12 Scope of Delivery ......................................................................................................................... 44
13 Repair and Replacement Parts Service, Calibration Center and Rental Instrument Service 44
14 Product Support ........................................................................................................................... 44


Product specificaties

Merk: Gossen Metrawatt
Categorie: Meetapparatuur
Model: GEOHM PRO

Heb je hulp nodig?

Als je hulp nodig hebt met Gossen Metrawatt GEOHM PRO stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Meetapparatuur Gossen Metrawatt

Handleiding Meetapparatuur

Nieuwste handleidingen voor Meetapparatuur