Giga Copper G4201TM Handleiding


Lees hieronder de šŸ“– handleiding in het Nederlandse voor Giga Copper G4201TM (5 pagina's) in de categorie Niet gecategoriseerd. Deze handleiding was nuttig voor 32 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/5
G4201TM
G.hn Master and Client
Quick start guide
For further informaī‡‘on and purchase enquiries
please contact info@gigacopper.net
1. Introducī‡‘on
With the G.hn modem G4201TM you can easily extend
your network via exisī‡‘ng data and telephone cables.
The devices are also suitable for the distribuī‡‘on of ī…­ber
opī‡‘c connecī‡‘ons from the ONT to the router via exisī‡‘ng
telephone line.
The modem can use any type of cable - both twisted pair
and non-twisted pair - for data transmission and
achieves a speed of approx. 1500 Mbit/s (sum of both
transmission direcī‡‘ons).
The devices are always connected in pairs - a master and
a client. The master determines how fast the data is
transferred towards the client and back
(download/upload).
In networks with several clients, a G.hn switch can be
used instead of several master modems (see
Installaī‡‘on). This enables the central administraī‡‘on of
all G.hn components.
2. Package content
ļ‚· G420 M Master or G4201TM Client 1T
ļ‚· DC-12V/1A Power adapter
ļ‚· RJ11/RJ11 telephone cable , 4- wire (SISO and MIMO) 1.5m
ļ‚· TAE-F/RJ11 , 4- pole (SISO and MIMO) plug
3. Technical data
ļ‚· Dimensions: 111.5 * 83 * 24.5 mm
ļ‚· Weight: 0,19 kg
ļ‚· Operaī‡‘ng temperature: 0Ā°C - 40Ā°C
ļ‚· Power consumpī‡‘on: < 3 Waī‡›
4. G.hn Speciī…«caī‡‘on
ļ‚· G.hn Wave2, 2-200 MHz
ļ‚· Connecī‡‘on type: SISO (1 wire pair, 2-200MHz) and
MIMO (2 wire pairs, 2- MHz) 100
ļ‚· Total bandwidth ca. 1500 Mbit/s ā€“
(Total Download and Upload)
ļ‚· Spliī‡ng of the bandwidth variable default: ā€“,
70% Download (from master client) to
30% Upload (from client master) to
ļ‚· Maximum permissible aī‡›enuaī‡‘on of the cable
connecī‡‘on: 75dB
5. Interfaces
Panel and LED descripī‡‘on
Labelling
Descripī‡‘on
12V DC
Power input
RST
Recessed reset buī‡›on (15 Sec .)
LINE
G.hn port
GE
Gigabit Ethernet Port
PWR LED
Displays power availability
LINE LED
Status of the G.hn connecī‡‘on
(Green - OK, Yellow - weak signal,
Oī…Ŗ - no connecī‡‘on)
GE LED
Ethernet Connecī‡‘on Status
6. Installaī‡’on
Variant 1 Point- -Point one master and client ā€“ ā€ž to ā€œ:
Variant 2 Connecī‡¤on to the Switch G4224T or G4200- ā€“8T/4T
7. Connecī‡’on type and wire assignment on device (RJ11 plug)
The G.hn connecī‡¤on can be established either via one wire pair (connecī‡¤on type SISO PHONE ) or = G.hn proī…‡le ā€œ 200MHzā€
via two wire pairs (connecī‡¤on type MIMO PHONE 100MHz MIMO ). The connecī‡¤on type must be = G.hn proī…‡le ā€œ ā€
conī…¾gured via web interface in both modems or via the G.hn switch.
The default seī‡°ng PHONE is one wire pair connecī†Æon (ā€œ 200MHzā€).
Wire assignment SISO
Variant 1 oint- -Point ā€“ ā€žP to ā€œ
Wire assignment SISO
Variant 2 Connecī‡¤on to Switch ā€“
Wire assignment MIMO
Variant 1 Point- -Point ā€“ ā€ž to ā€œ
8. Installaī‡Žon notes
ļ‚· The wires of a pair can be connected straight or crossed.
ļ‚· Maximum range of the G.hn connecī‡on depends on the type of cable used, the connecī‡on type and the environment.
Typical values for a 0.5 mm twisted pair cable: connecī‡on possible up to approx. 600/800 metres (SISO/MIMO),
maximum bandwidth of 1500 Mbit/s - up to approx. 100/200 metres (SISO/MIMO).
ļ‚· For longer cables ( approx. 100-150m), the bandwidth can be increased by up to 15% (SISO) resp. up to 25% (MIMO) up
by adjusī‡ng the signal level. For this purpose, the "Range opī‡mizaī‡on model" must be set to "Long" in the web
interface of both devices resp. the "LongRangeMode" seī‡œng must be acī‡vated in the G.hn switch.
ļ‚· The negoī‡ated bandwidth can be queried via the web interface of the devices (see point 11).
ļ‚· The bandwidth split of the G.hn connecī‡on is variable. It can be set between 80/20% and 20/80%. In the factory seī‡œng,
70% of the bandwidth is reserved for download (direcī‡on master to client) and 30% for upload (direcī‡on client to
master). The allocaī‡on can be conī…­gured via master web interface (menu G.hn DownStream / UpStream Raī‡o) resp. via
the G.hn switch.
ļ‚·
9. Administraī‡Žon
10. IP address
The devices do not require IP addresses from the local network segment during operaī‡on, because they transmit the data
traī…·c via the MAC addresses. In the factory seī‡œng, they do not obtain any addresses from the local DHCP server.
If desired, staī‡c IP addresses can be conī…­gured or the DHCP client can be acī‡vated ("IP" menu in the web interface).
11. Query of the negoī‡Žated bandwidth
The negoī‡ated bandwidths for both direcī‡ons can be queried via web interface of each modem. The values shown are
gross data transmission rates on physical layer (PHY). The transmission rate on applicaī‡on layer is approx. -20% lower.15
IP-Adress: 192.168.10.252 (Master), 192.168.10.253 (Client). Login passwort: paterna Factory reset passwort: betera ,
Login via Webinterface
ļ‚· Connect your computer to the G.hn modem via the GE
port..
ļ‚· Assign a ī…­xed IP address to your computer, e.g.
192.168.10.100 (network mask 255.255.255.0).
ļ‚· Open a web browser and connect to 192.168.10.252 or
192.168.10.253
ļ‚· Login with the standard password: paterna
It is possible to transmit an analogue telephone line on the same
line parallel to the G.hn signal. Use a DSL splinter for this purpose.


Product specificaties

Merk: Giga Copper
Categorie: Niet gecategoriseerd
Model: G4201TM

Heb je hulp nodig?

Als je hulp nodig hebt met Giga Copper G4201TM stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Niet gecategoriseerd Giga Copper

Handleiding Niet gecategoriseerd

Nieuwste handleidingen voor Niet gecategoriseerd