Geist RCMW248-103PH6TL21-OD Handleiding

Geist Stekkerdoos RCMW248-103PH6TL21-OD

Lees hieronder de 📖 handleiding in het Nederlandse voor Geist RCMW248-103PH6TL21-OD (4 pagina's) in de categorie Stekkerdoos. Deze handleiding was nuttig voor 38 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/4
Part Number:
Cat ego ry:
Sub Category:
Power Configuratio n:
Physical Configuration:
Description:
Product Summary:
Monito ring:
RCMW248-103PH6TL21-OD
RCMW248-103PH6TL21-OD
Switched
Unit Level
30A, 120/208V WYE, 8.6kW
72 in / 1829 mm, Vertical
The RCMW248-103PH6TL21-OD provides hands-on control remotely. While Monitored PDUs can display
informat ion remotely, this Swit ched unit offers the abilit y to use that information and stay in control of
individual power outlets. The RCMW248-103PH6TL21-OD manages whatever issues arise wit h the click of a
few butt ons on a smart phone or computer. Also, disable problem equipment by cut ting power to specific
outlets, reboot equipment remotely by turning power on and off, and save time and money by avoiding
sending live technicians to the source of the issue.
DCIM Enabled - The RCMW248-103PH6TL21-OD easily int egrat es wit h Geist DCIM software, which collects
and report s crit ical power and environmental data for mult iple PDUs in a single user int erface. Users gain
immediate remote access to trends, alarms and hist ories of devices in the data center through a standard
Web browser. Geist DCIM saves both time and cost associated with managing each device individually.
Cont act your Geist rep for more details.
RCMW248-103PH6TL21-OD - Switched, Unit Level, + Environmental Monit oring -- 30A, 120/208V WYE, 3
Phase, Vertical, (18) Locking IEC C13, (6) Locking IEC C19, breakered, 10 ft power cord with L21-30P, Input
and per Phase power monitoring with Outlet swit ching. Environment al monitoring via opt ional remote
sensors. Ethernet and RS232 connect ivity. Local LCD display. Black Powder Coat .
Input and per Phase power monitoring with Outlet swit ching. Environment al monitoring via opt ional remote
sensors. Ethernet and RS232 connect ivity. Local LCD display.
Plug Form:
L21-30P
Receptacle:
Locking IEC C13
(Quantity: 18)
Locking IEC C19
(Quantity: 6)
RCMW248-103PH6TL21-OD
Product Specification and Options:
Monitoring Input and per Phase power monitoring with Outlet switching. Environmental monitoring via optional remote sensors.
Ethernet and RS232 connectivity. Local LCD display.
Monitoring Level 1 Aggregate - Total Unit Monitoring (kWh, W, VA, PF)
Monitoring Level 2 Phase (A, B, C) Monitoring (kWh, W, VA, PF, V, A)
Remote Power Management Individual Outlet Switching with Optional User Defined Time Delays with Sequential Power-up
Quantity Of Inputs 1
Voltage 120/208V WYE
Current 30A x 3 Phase WYE
VA per Input (Load Capacity) 8.6kW
Frequency 50/60 Hz
Over Current Protection (3) 20A Double Pole Magnetic Breakers
Switch Breaker/Switch Combination
Indicators - LED(s) 24
Activity LED 1
Idle LED 1
Power LED 1
Scrolling Digital Display Yes
Power Cable Wire Gauge 10/5
Power Cable Length 10ft
Plug Type NEMA L21-30P Twistlock
Combined Total Receptacle/Socket
Quantity
24
Receptacle/Socket Type #1 Locking IEC C 13
Quantity on Face #1 18
Quantity per Breaker and Phase
Combination #1
6
Style #1 Individual
Maximum Output per
Receptacle/Socket #1
15A
Voltage per Receptacle/Socket #1 208V
Receptacle/Socket Type #2 Locking IEC C 19
Quantity on Face #2 6
Quantity per Breaker and Phase
Combination #2
2
Style #2 Individual
Maximum Output per
Receptacle/Socket #2
16A
Voltage per Receptacle/Socket #2 208V
Internal RMS Voltage Sensor Yes


Product specificaties

Merk: Geist
Categorie: Stekkerdoos
Model: RCMW248-103PH6TL21-OD