Fredrick Ramond FR45601BNI Handleiding

Fredrick Ramond Lamp FR45601BNI

Lees hieronder de 📖 handleiding in het Nederlandse voor Fredrick Ramond FR45601BNI (3 pagina's) in de categorie Lamp. Deze handleiding was nuttig voor 7 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/3
FR45601BNI/FBZ
MIME
ASSEMBLY I N STR UC TIONS
Assembly of this fixture will be accomplished by first assembling the main body,
installing the mounting hardware to the junction box, hanging the fixture and then
installing the shade and crystals.
SAFETY WARNING: Read wiring and grounding instructions [FRIS 18]
and any additional directions. Turn power supply off during installation. If new wiring
is required, consult a qualified electrician or local authorities for code requirements.
STEP 1
1
STEP 2 Refer to Hanging Instruction Sheet to hang fixture. Then refer[FRIS19-41 ]
back to this sheet to continue installation of this fixture.
STEP 3
1
2
3
[DRAWING 1]
Bulbs: 3-60W CAND. Replacement Parts: SHADE: R45601SH (BNI FINISH),
R455601AMBSH ( fbz FINISH),
R45602CRY-A
01.01.13
3d
ce
1b
e
4
2
5
After unpacking fixture main body can be installed prior to attaching the shade.
Take shade and line up holes in tabs with the holes in (1) (d)
end of arms . Shade tab shold be on top of the arm -see . (b) Drawing 1
Slip flat head screw (2) through hole in arm and hole in shade
tab. Thread barrel knob onto end of screw to secure shade.(3) (2)
Repeat process with the remaining arms.
Thread finial (4) onto threaded tube (t) found at the bottom of the fixture.
Attach crystals (5) at point (e) as indicated in .Drawing 1
e
5
t
4
HA GI NSTN NG I RUCT NSIO
FRIS19 41-
SA Y FET WA NG:RNI Read wiring and grounding instructions [FRIS 18]
and any additional directions. Turn power supply off during installation. If new wiring
is required, consult a qualified electrician or local authorities for code requirements.
EP 1ST
1 Shut off electrical current before starting. If the fixture you are replacing is
turned on and off by a wall switch, simply turn the switch off. If not, remove the
appropriate fuse (or open the circuit breakers) until the fixture is dead.
N• DO OT restore current - either by fuse, breaker or switch - until the new
fixture is completely wired and in place.
EP 2ST
[DRA N ]WI G 2
01.01.13
3
4
1 Prepare mounting strap (a) by threading screws (b) into appropriately threaded hole
(h) - see Drawing 1. Make sure spacing of screws matches spacing of mounting holes
(3) in Canopy (c) -see Drawing 2.
2 Install mounting strap (a) to junction box (j), with two 8-32 screws (1) - see Drawing 2.
1 To mount fixture to ceiling , slip screws (b) in mounting strap (a) through
holes (3) in canopy (c) - see Drawing 2.
2 Hold canopy (c) up to ceiling and thread deocrative knobs (4) onto end of
screws (b) and tighten to secure fixture to ceiling.
3 Return to previous instruction sheet to complete fixture assembly.
c
[DRA N ]WI G 1
EP 3ST
Make electrical connections from supply wire to fixture lead wires. Refer to
instruction sheet and follow all instructions to make all necessary [FRIS18]
wiring connections. Then refer back to this sheet to continue installation of
this fixture.
EPST 4
a
1
b
a
j
b
WIRING AND GROUNDING INSTRUCTIONS
SAFETY WARNING: Read wiring and grounding instructions
[FRIS 18] and any additional directions. Turn power supply o during installation. If new
wiring is required, consult a qualified electrician or local authorities for code require-
ments.
STEP 1 WIRING INSTRUCTIONS
Indoor Fixtures
1 Connect positive supply wire (a) (typically black or the smooth, unmarked side of
the two-conductor cord) to positive fixture lead (b) with appropriately sized twist
on connector - See Drawings 1 or 2.
2 Connect negative supply wire (c) (typically white or the ribbed, marked side of
the two-conductor cord) to negative fixture lead (d).
3 Please refer to the grounding instructions below to complete all electrical
connections.
Outdoor Fixtures
1 Connect positive supply wire (a) (typically black or the smooth unmarked side of
the two-conductor cord) to positive fixture lead (b) with appropriately sized twist
on connector - See Drawings 2 or 3.
2 Connect negative supply wire (c) (typically white or the ribbed, marked side of
the two-conductor cord) to negative fixture lead (d).
3 Cover open end of connectors with silicone sealant to form a watertight seal.
• If installing a wall mount fixture, use caulk to seal gaps between the fixture
mounting plate (backplate) and the wall. This will help prevent water from
entering the outlet box. If the wall surface is lap siding, use caulk and a fixture
mounting platform specially.
4 Please refer to the grounding instructions below to complete all electrical
connections.
STEP 2 GROUNDING INSTRUCTIONS
Flush Mount Fixtures
For positive grounding in a 3-wire electrical system, fasten the fixture ground
wire (e) (typically copper or green plastic coated) to the fixture mounting strap
(1) with the ground screw (2) - See Drawing 1.
Note: On straps for screw supported fixtures, first install the two mounting
screws in strap.
Any remaining tapped hole may be used for the ground screw.
Chain Hung Fixtures
Loop fixture ground wire (e) (typically copper or green plastic coated) under the
head of the ground screw (2) on fixture mounting strap (1) and connect to the
loose end of the fixture ground wire directly to the ground wire of the building
system with appropriately sized twist-on connectors - See Drawing 2.
Post-Mount Fixtures
Connect fixture ground wire (e) (typically copper or green plastic coated) to
power supply ground with appropriately sized twist-on connector inside post.
Cover open end of connector with silicone sealant to form a watertight seal - See
Drawing 3.
[drawing 1]
[drawing 2]
[drawing 3]
1.30.08
a c e
1
b d
supply wire
xture leads
twist-on
connectors
2
a c
e
e
1
b d
2
a c e
e
b d
twist-on
connectors
supply wire
xture leads
supply wire
xture leads
twist-on
connectors
FRIS18


Product specificaties

Merk: Fredrick Ramond
Categorie: Lamp
Model: FR45601BNI

Heb je hulp nodig?

Als je hulp nodig hebt met Fredrick Ramond FR45601BNI stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Lamp Fredrick Ramond

Handleiding Lamp

Nieuwste handleidingen voor Lamp