Flir Breach PTQ136 Handleiding

Flir Thermometer Breach PTQ136

Lees hieronder de πŸ“– handleiding in het Nederlandse voor Flir Breach PTQ136 (2 pagina's) in de categorie Thermometer. Deze handleiding was nuttig voor 43 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/2
BREACHTM
Q uick St ar t G u id e
Button ●
β€’ Long press when monocular is OFF – TURNING ON
β€’ Hold down (>8s) when monocular is ON – TURNING OFF
β€’ Long press when monocular is ON – MAIN MENU
β€’ Single Click – SINGLE IMAGE SNAPSHOT / SELECTION (in menu)
β€’ Double Click – RECORD VIDEO / STOP RECORDING
Button β–²
β€’ Short press – SCREEN BRIGHTNESS INCREASE
β€’ Long press – E-ZOOM INCREASE
β€’ Navigation in menu - UP
Button β–Ό
β€’ Short press – SCREEN BRIGHTNESS DECREASE
β€’ Long press – E-ZOOM DECREASE
β€’ Navigation in menu - DOWN
Buttons + β–² β–Ό
β€’ Simultaneously hold the two buttons –
TRIGGERS UCMNUC/FFC* MANUALLY
* UCMNUC/FFC - User Controlled Manual Non Uniformity
Correction/ Flat-Field Correction
Install CR123A battery as follows:
1. Unscrew the battery cap.
2. Insert the CR123A battery into the battery
compartment, observing the polarity markings
on the body of the monocular.
3. Replace the battery cap.
1BATTERY INSTALLATION
2CONTROL PANEL BUTTONS
Battery Cap
Battery
Battery Polarity
Symbol
Diopter
Adjustment Ring
While looking through the eyepiece, rotate the diopter
adjustment ring to optimize the sharpness of the image
in the viewnder.
3DIOPTER ADJUSTMENT
●
β–²
β–Ό
For warranty information and product registration visit:
www.ir.com
Most setup options can be accessed from the MAIN
MENU.
To display the MAIN MENU, hold down the central
● button on the control panel.
The PALETTE menu allows you to select from a
choice of temperature imaging modes.
The palettes act as color templates for visualization
of temperature changes in the scene.
The ENHANCEMENT menu settings allow the user
to take advantage of advanced signal processing
algorithms, and improve the quality of the image
under a variety of different thermal environments.
The ING menu allows the operator to delete RECORD
selected image and video les stored in the camera.
The SETTINGS menu allows you to make compass
calibration, to change the position of image on the
screen, pair a new remote with the camera, as well
as to restore the settings to their factory defaults.
The Firmware (FW) revision number is listed at the
bottom of the menu display.
Select POWER DOWN item of Main Menu and then
push ● button to turn monocular off. Or hold down
● button for more than 8 seconds.
5MAIN MENU
6PRESETS
MAIN MENU
> EXIT
PALETTE
ENHANCEMENT
RECORDING
SETTINGS
POWER DOWN
ENHANCEMENT
> EXIT
PRESETS <> DEFAULT
CONTRAST <> 100
SHARPNESS <> 90
SMARTSCENE <> 20
GAIN <> 138
AGC SPEED <> 85
VIDEO RECORD
> EXIT
FILE <> No Files
DELETE
SETTINGS
> EXIT
CAL. COMPASS
LEFT MARGIN <> 0
TOP MARGIN <> 0
LEARN REMOTE
FACTORY RESET
FW: xxxxxxxxxxxx
PALETTE
> EXIT
WHITE HOT
BLACK HOT
RAINBOW_HC
IRONBOW
SEPIA
ARCTIC
OUTDOOR ALLERT
ITEM RANGE DEFAULT SKY/SEA INDOORS OUTDOORS
Contrast 50 to 250 100 100 100 100
Sharpness 0 to 800 90 100 75 110
Smart Scene 0 to 100 20 30 10 80
Gain 25 to 800 138 120 110 138
AGC Speed 0 to 100 85 85 85 99
18 - 0142- OTS


Product specificaties

Merk: Flir
Categorie: Thermometer
Model: Breach PTQ136

Heb je hulp nodig?

Als je hulp nodig hebt met Flir Breach PTQ136 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Thermometer Flir

Handleiding Thermometer

Nieuwste handleidingen voor Thermometer

Owon

Owon TI219 Handleiding

21 December 2024
TFA

TFA 12.1004 Handleiding

21 December 2024
Optex

Optex PT-U80 Handleiding

16 December 2024
Optex

Optex PT-7LD Handleiding

16 December 2024
Ebro

Ebro TFI 260 Handleiding

15 December 2024
Ebro

Ebro TFI 54 Handleiding

15 December 2024
EMOS

EMOS E0522 Handleiding

13 December 2024
Senseca

Senseca PRO 111 Handleiding

11 December 2024