FireAngel FP1000W2-R Handleiding


Lees hieronder de šŸ“– handleiding in het Nederlandse voor FireAngel FP1000W2-R (1 pagina's) in de categorie Niet gecategoriseerd. Deze handleiding was nuttig voor 53 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/1
WG-2 WIRELESS INTERLINK GATEWAY
INSTALLATION GUIDE
Technical Support
Online: www.ļ¬reangeltech.com/support
E-mail: speciļ¬cation@ļ¬reangeltech.com
Phone: 0330 094 5830
Fire & Rescue Customers: 0800 141 2561
www.ļ¬reangeltech.com Note: This user manual is also available in large
text and other formats.
Ā© FireAngel Safety
Technology Limited,
Vanguard Centre,
Coventry CV4 7EZ, UK
GN5804R1
Model No.
WG-2
30mm
Drill hole spacing
WG-2 Gateway Rear Panel Guide
Certiļ¬cation information
and Model Number
Power rating and
Radio Frequency Number
Brand, device name
and network protocol
MAC address
information
Ethernet cable point Power cable point
Graphic number information
WS2 learn-in button
Customer Service
information
Manufacturer name
and address
Gateway status icons
Wall mounting lugs
Mounting removal
insertion point
Note: Make a note of the MAC address prior to permanent installation as you will need this when
activating the Gateway for the ļ¬rst time.
To remove the Gateway from a wall: Insert a small screwdriver into the hole on the side and use it
to slide the Gateway up. The Gateway will lift off the screws that attach it to the wall.
3. Connect Power
cable here
4. Connect Ethernet
cable here
1. INSTALLATION INSTRUCTIONS
1. The Gateway is designed to lie īœ»at or be secured to a wall.
2. If required, use the supplied plastic anchors and screws to ļ¬t the Gateway to the wall.
Mounting on a wall:
Please ensure that you
use the screws provided,
as they were chosen
speciļ¬cally for use with
this product.
Use the template provided
(see below) for guidance on
marking hole positions. Drill
holes into the wall. Insert the
plastic wall plugs. Screw in
the screws. Ensure screws
are protruding from the
wall by 3mm to allow the
Gateway to slot onto screws.
2. SETTING UP YOUR GATEWAY
Follow the set-up instructions at: www.ī™«reangeltech.com
Please note: An internet connection is required when setting up an alarm network for the ļ¬rst time,
in conjunction with the Gateway.
When you interlink the Gateway with the rest of the alarm network, as directed in the online set-up
instructions, you will need to access the ā€˜WS2 learn-in buttonā€™ ( ) located on the rear of the WG-2
Gateway.
(Please refer to the ā€˜WG-2 Gateway Indicatorsā€™ section for the Gateway status
information.)
The WG-2 Gateway allows for Smart RF compatible devices to connect to the
internet. The FireAngel Connected app works in conjunction with the Gateway to
enable real time alerts, networking and testing of your safety alarm system.
Smart RF operates on FireAngelā€™s Wi-Safe 2 networking protocol and is compatible
with other Wi-Safe 2 products.
3. WG-2 GATEWAY INDICATORS (LEDs)
NOTE: The LEDs on the front of the WG-2 Gateway are used to indicate when it is
powered-up, connected to the internet, in fault mode or requiring registration - as
detailed below. If the Gateway is mounted on a wall, the LED descriptions located on
the back of the device will not be visible. You can still learn about the status of the
Gateway using the icons featured in table below.
STATUS COMMUNICATION
GREEN
FAULT
RED
POWER
GREEN
ACTION
NEEDED
Initial
Gateway
power-up
Illuminated
Connect Gateway
to the internet via
the ethernet cable
Gateway
unregistered Illuminated Illuminated Illuminated Register the
Gateway online
Gateway
connected Illuminated Illuminated None required
Connection
fault Illuminated Illuminated
Check your
internet
connection is
working
LIMITATIONS
Wi-Safe 2 is not a life safety protocol and should not be relied upon for life safety. If
your internet connection is lost, communication from the WG-2 (i.e. to cloud or mobile
devices) may not be possible. The local Smart RF alarm network will still continue to
operate as a stand-alone system and does not rely on an internet connection to do so.
TECHNICAL SPECIFICATION
The WG-2 Gateway is designed to be
installed in conjunction with Smart RF
compatible devices (Wi-Safe 2 protocol)
For more information visit:
www.ļ¬reangeltech.com
The WG-2 is powered by an AC Adaptor.
Input: 100-240V AC 50/60Hz
Output: 5V DC 1A
AC Adaptor Model Number:
KSAS0050500100VKD
Storage and transportation conditions:
0Ā°C to +35Ā°C
Independently tested to RF standard:
EN 300 220-2, EN 301 489-3, EN 301 489-1
Max RF power: +10dBm
Frequency 868MHz
Hereby, FireAngel Safety Technology
Limited declares that this product is in
compliance with the essential requirements
and other relevant provisions of Directive
2014/53/EU. The declaration of conformity
may be consulted at http://spru.es/WG-2
Manufacturer:
FireAngel Safety Technology Limited,
Vanguard Centre, Sir William Lyons Rd,
Coventry, CV4 7EZ, UK
WARRANTY
For information on individual alarm warranty please refer to the main alarm manual.
FireAngel Safety Technology Limited warrants to the original purchaser that its enclosed WG-2 to
be free from defects in materials and workmanship under normal residential use and service for
a period of 5 (ļ¬ve) years from the date of purchase. Provided it is returned with proof of purchase
date, FireAngel Safety Technology Limited hereby warrants that during the 5 (ļ¬ve) year period
commencing from the date of purchase FireAngel Safety Technology Limited, at its discretion,
agrees to replace the unit free of charge.
The warranty on any replacement WG-2, will last for the remainder of the period of the original
warranty in respect of the wireless module originally purchased ā€“ that is from the date of original
purchase and not from the date of receipt of the replacement product.
FireAngel Safety Technology Limited reserves the right to offer an alternative product similar to
that being replaced if the original model is no longer available or in stock. This warranty applies to
the original retail purchaser from the date of original retail purchase and is not transferable. Proof
of purchase is required. This warranty does not cover damage resulting from accident, misuse,
disassembly, abuse or lack of reasonable care of the product, or applications not in accordance with
the user manual. It does not cover events and conditions outside of FireAngel Safety Technology
Limitedā€™s control, such as Acts of God (ļ¬re, severe weather etc.). It does not apply to retail stores,
service centres or any distributors or agents. FireAngel Safety Technology Limited will not recognise
any changes to this warranty by third parties.
FireAngel Safety Technology Limited shall not be liable for any incidental or consequential damages
caused by the breach of any expressed or implied warranty. Except to the extent prohibited by
applicable law, any implied warranty of merchantability or ļ¬tness for a particular purpose is limited
in duration for 5 (ļ¬ve) years. This warranty does not affect your statutory rights. Except for death or
personal injury, FireAngel Safety Technology Limited shall not be liable for any loss of use, damage,
cost or expense relating to this product or for any indirect or consequential loss, damages or costs
incurred by you or any other user of this product.
DISPOSAL
Waste electrical products should not be disposed of with your other household waste, but within the
waste electronic and electrical equipment (WEEE) recycling scheme.
WARNING: Do not attempt to disassemble.
Do not burn or dispose of in ļ¬re.
Privacy Statement
FireAngel Safety Technology Limited takes your privacy seriously. Our devices and products collect
data to enable us to provide services (including product support and notiļ¬cations) and to enable us
to predict ļ¬re risks and create statistics. Details of the data we collect, how we use and how long we
keep that data are contained in our privacy notice which is available at https://www.ļ¬reangel.co.uk/
FACTPP. If you have any queries about how we use your personal data or would like to exercise any
of your rights, including your right to object where we rely on legitimate interests, please contact us
at speciļ¬cation@ļ¬reangeltech.com or call 0330 094 5830.


Product specificaties

Merk: FireAngel
Categorie: Niet gecategoriseerd
Model: FP1000W2-R

Heb je hulp nodig?

Als je hulp nodig hebt met FireAngel FP1000W2-R stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Niet gecategoriseerd FireAngel

Handleiding Niet gecategoriseerd

Nieuwste handleidingen voor Niet gecategoriseerd