6.
8.
NEBM-L10G14-EH-...-Q...-LE12
Motor cable
Festo SE & Co. KG
Ruiter Straße 82
73734 Esslingen
Germany
+49 711 347-0
www.festo.com
Assembly instructions
8156480
2024-03
[8156482]
8156480
Original instructions
© 2024 all rights reserved to Festo SE & Co. KG
1 Applicable documents
All available documents for the product
èwww.festo.com/sp.
2 Safety
2.1 Safety instructions
–Before working on the product: Switch off the power supply, ensure that it is off
and secure it against being switched on again.
2.2 Intended use
The motor cable connects the stepper motor EMMB-ST with the servo drive
CMMT-ST.
2.3 Training of qualified personnel
Work on the product may only be carried out by qualified personnel who can
evaluate the work and detect dangers. The qualified personnel are trained in
electrical engineering.
3 Additional information
–Contact the regional Festo contact if you have technical problems
èwww.festo.com.
–Accessories èwww.festo.com/catalogue.
4 Structure
4.1 Product design
1 2
34
5
Fig. 1: Product design
1
Hybrid socket L10
2
Wire end (12x)
3
Shielded connection
4
Cable
5
Contact assignment identification
4.2 Contact assignment for motor and brake
Electrical connection1
Field device side
Signal Electrical connection2
Controller side X6
[1]Hybrid socket [2]Wire ends1)
1 Phase A RD
2 Phase A/ BN
3 BR+ GNWH
4 BR- BUWH
5 Shielding –
6 Not assigned –
13 Phase B BK
14 Phase B/ WH
1) Colour code in accordance with IEC 60757:2021-06
Tab. 1: Contact assignment for motor and brake
4.3 Encoder contact assignment
Electrical connection1
Field device side
Signal Electrical connection2
Controller side X2
[1]Hybrid socket [2]Wire ends1)
7 SLO+ VT
8 SLO- YE
9 MA+ GY
10 MA- PK
11 +5V RD
12 GND(0V) BU
1) Colour code in accordance with IEC 60757:2021-06
Tab. 2: Encoder contact assignment
5 Mounting
5.1 Mounting electrical connection1
1. Align the hybrid socket[1].
2. Plug the hybrid socket[1] into the connection and click it into place.
5.2 Strain relief for electrical connection 1
• Fix the cable sheath in the section before the hybrid socket.
ÄNo strain on the hybrid socket.
5.3 Mounting electrical connection2
1. Attach the shield connection[3] to the servo drive with the shield clamp
èServo drive operating instructions CMMT-ST.
2. Connect the wire ends[2] in accordance with the contact assignment. Note
the contact assignment identification[5].
5.4 Strain relief for electrical connection 2
• Fix the cable sheath in the area in front of the wire ends.
ÄNo strain on the wires.
5.5 Wiring
Character-
istics
Cable characteristics Wiring
-E Suitability for energy chains In energy chain or flexible
Tab. 3: Wiring
5.6 Mounting in energy chain
1. Lay out the energy chain lengthways.
2. Place the cables in the energy chain without twisting them.
3. Separate cables from each other using separators/drilled holes.
4. Do not bind cables in bundles.
5. Maintain spaceX. X 10%of the cable diameterD.>
With the energy chain hanging vertically: increase the spaceX.
Align the energy chain in the working position:
–Make sure that the radius is greater than the bending radiusR of the
cables.
–The cables can move freely in the bending radius KR of the energy chain.
ÄThe cable movement is not forced by the energy chain.
7. Mount the energy chain corresponding instruction manual.è
Fasten the cables:
–for short energy chains with a length 1m at both ends of the energy<
chain
–for long sliding energy chains with a length 1m at the driver end only>
9. Do not move cables all the way to the fastening point.
ÄThe mounting spaceA between the fastening point and bending move-
ment is maintained.
NOTICE
Damage to cables if the chain breaks.
• Replace cables after a chain break.
NOTICE
Malfunction and material damage due to vertically suspended cables.
The cables stretch.
• Regularly check the length of the cables.
• Readjust the cables if required.
6 Technical data
NEBM-L10G14-EH-...-...-LE12 -Q6(N) -Q7(N) -Q9(N)
Certificates, declaration of conformity è
www.festo.com/sp
Cable characteristic Suitability for energy chains
Cable function 3x motor cable
Cable composition [mm²] 4x0.5+2x0.5
+6x0.15
4x0.75+2x0.5
+6x0.15
4x1.5+2x0.5
+6x0.15
Shielding Shielded
Cable diameter D1 [mm] 10.5 10.8
Diameter of shield sleeve D2 [mm] Approx.12.5
Mounting space A [mm] 250³
Current rating at 40°C [A] 7.6 11.7 17.8
Surge resistance [kV] 1.5
Operating voltage range
DC UB[V] 0…48
Bending radius
Fixed cable installation R [mm] 42 43.2³ ³
Flexible cable installation R [mm] 78.75 81³ ³
Ambient temperature
Fixed cable installation [°C] –40…+90
Flexible cable installation [°C] –25…+80
Material
Cable sheath TPE-U(PUR)
Insulating sheath PP
Electrical connection1
Function Field device side
Connection type Hybrid socket
Connection technology Plug patternL10
Number of pins/cores 14
Assigned pins/cores 13
Type of mounting Snap-locking
Degree of protection In
assembled state
IP20
Electrical connection2
Function Controller side
Connection type Cable
Connection technology Open end
Number of pins/cores 12
Assigned pins/cores 12
Wire ends Wire ferrule
Degree of protection In
assembled state
IP20
Tab. 4: Technical data


Product specificaties

Merk: Festo
Categorie: Niet gecategoriseerd
Model: NEBM-L10G14-EH-5-Q6N-LE12

Heb je hulp nodig?

Als je hulp nodig hebt met Festo NEBM-L10G14-EH-5-Q6N-LE12 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Niet gecategoriseerd Festo

Handleiding Niet gecategoriseerd

Nieuwste handleidingen voor Niet gecategoriseerd