Fenton RP161LW Handleiding


Lees hieronder de 📖 handleiding in het Nederlandse voor Fenton RP161LW (12 pagina's) in de categorie Platenspeler. Deze handleiding was nuttig voor 73 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/12
RP161 Record Player HQ BT
Ref. nr.: 102.130, 102.132
INSTRUCTION MANUAL
GEBRUIKSAANWIJZING
BEDIENUNGSANLEITUNG
MANUAL DE INSTRUCCIONES
MANUEL D'INSTRUCTIONS
V1.1
2
ENGLISH
Congratulations to the purchase of this Fenton product. ease read this manual thoroughly prior to using the unit in order to Pl
benet fully from all features.
Read the manual prior to using the unit. Follow the instructions in order not to invalidate the warranty. Take all precautions to
avoid re and/or rical shock epairs must only be carried out by a qualied technician in order to avoid electrical shock. elect . R
Keep the manual for future reference.
- Prior to using the unit, please ask advice from a
specialist. When the unit is switched on for the rst me, fi ti
some smell may occur This is normal and will disappear .
after a while.
- The unit contains voltage carrying parts. Therefore do
NOT open the housing.
- Do not place metal objects or pour liquids into the unit
This may cause electrical shock and malfuncti . on
- Do not place the unit near heat sources such as
radiators, etc. Do not place the unit on a vibrating
surface. Do not cover the ventilation holes.
- The unit is not suitable for continuous use.
- Be careful with the mains lead and do not damage it. A
faulty or damaged m s lead can cause electrical shock ain
and malfunction.
- When unplugging the unit from a mains outlet, always
pull the plug, never the lead.
- Do not plug or unplug the unit with wet hands.
- If the plug and/or the mains lead are damaged, they
n be replaced by a qualied technician. eed to
- If the unit is damaged to such an extent that internal
parts are visible, do NOT plug the unit into a mains outlet
and DO NOT switch the unit on. Contact your dealer. Do
NOT connect the unit to a rheostat or mmer. di
- To avoid re and shock hazard, do not expose the unit to
rain and moisture.
- All repairs should be carried out by a qualied technician
only.
- Connect the unit to an earthed mains outlet (220-
240Vac/50Hz) protected by a 10-16A fuse.
- During a thunderstorm or if the unit will not be used for a
longer period of time, unplug it from the mains. The rule
is: Unplug it from the mains when not in use.
- If the unit has not been used for a longer period of time,
condensation may occur. Let the unit reach room
temper ure before you switch it on. Never use the unit in at
humid rooms or outdoors.
- To prevent accidents in companies, you must follow the
applicable guide lines and follow the instructions.
- Do not repeatedly switch the xture on and o. This
shortens t life time. he
- Keep the unit out of the reach of children. Do not leave
the unit unattended.
- Do not use cleaning sprays to clean switches. The
residues of these sprays cause deposits of dust and
grease. In case of malfunction, always seek advice from
a specialist.
- Do not force e controls. th
- This unit is with speaker inside which can cause
magnetic eld. Keep this unit at least 60cm away from
computer or TV.
- his unit have a ilt-in lead-acid rechargeable battery. If t bu
Please recharge the battery every 3 months if y are ou
not go to use the unit for a long period of time. Or the ing
battery may be damaged.
- If the battery is damaged please replace with same
specications battery. And dispose the damaged battery
environment friendly.
- If the unit has fallen, always have checked by it a
qualied technician before you switch the unit on again.
- Do not use chemicals to clean the unit. They damage the
varnish. Only clean the unit with a dry cloth.
- Keep away from electronic equipment that may cause
interference.
- Only use origi l spares for repairs, otherwise serious na
damage and/or dangerous radiation may occur.
- Switch the unit o prior to unplugging it from the mains
and/or other equipment. Unplug all leads and cables
prior to moving the unit.
- Make sure that the mains l can t be damaged whead no en
people walk on it. Check the mains lead before every use
for damages and faults!
- The mains voltage is 220-240Vac/50Hz. Check if power
outlet match. If you travel, make sure that the mains
voltage of the country is suitable for this unit.
- Keep the or nal packing material so that you can igi
transport the unit in safe conditions.
This mark attracts the attention of the user to high voltages that are present inside the housing and that are of sucient
magnitude to cause a shock hazard.
This mark attracts the attention of the user to important instructions that are contained in the manual and that he should
read and adhere to.
The unit has been certied CE. It is prohibited to make any changes to the unit. They would invalidate t CE c ticate anhe er d
their guarantee!
NOTE: To make sure that the unit will function normally, it must be used in rooms with a temperature between 5°C/ °F 41 and
35 95°C/ °F .
Electric products must not be put into household waste. Please bring them to a recycling centre. Ask ur local authorities or your yo
dealer about the way to proceed. The specications are typical. The actual values can slightly change from one unit to the other.
Specications can be changed without prior notice.
Do not attempt to make any repairs yourself. This would inva d your warranty. Do not make any changes to the unit. This would also invalid li
your warranty. The warranty is not applicable in case accidents or damages caused by inof appropriate use or disrespect of the warnings
contained in this manual. Fenton cannot held responsible for rsonal injuries caused by a disrespect of the safety recommendations be pe
and warnings. This is also applicable to l damages in whatever form. al
3
OVERVIEW
1. Lever Lift
Raises and lowers the tonearm.
2. Tone A rm
3. 33 / 45 / 78 RPM Switch
This switch controls the RPM of the turntable platter.
4. Autostop Switch ON/OFF
This switch turns auto stop on or o. When the automatic stop is
enabled, the platform will start rotating soon as the tone arm is as
placed over the record and will stop rotating when it has reached the
end of the record. Some vinyl records stop fore the en do not be d or
stop when the end is reached. In this case set Auto-stop to OFF.
5. Arm Locking C lip
This specially designed arm clip secures the tonearm while at rest or
when not in use. The arm clip has been designed to remain in the up
position while unlocked.
6. Cartridge with Needle
When the turntable is not in use, it is recommendable to place the
removable protection cover on the stylus.
7. Power & Volume C trol Kn on ob
To power on the record player, turn this knob clockwise until it clicks.
When powered on, use this knob to adjust the volume. To turn o the
record player, turn this knob counter clockwise until it clicks.
8. 45RPM Adapter
This adapter allows you to play 45RPM records.
9. Platter
Place your cord here. re
10. Spindle
11. RCA Line Output
The audio from a playing vinyl record is sent to this line-level coaxial audio output. This must not be connected to phono
level devices.
12. DC IN Port
Connecting the 5Volt/DC power adapter.
13. Dust Cover
BT CONNECTI ON
1. Turn on the device. The default mode is BT streaming mode (when the auto-stop ON/OFF switch is at ON position). The
indicator will ash in blue color.
2. Turn on the BT function on your mobile device and search for Fenton recordplayer . After successful pairing, the indicator “ ”
will stop ashing. You can play your music of your mobile phone or tablet PC on this turntable player. now
Turn the VOLUME CONTROL KNOB to adjust the volume he mobile device s volume control also impacts the overall (t
volume level).
OPERATION
1. Connect the record player with the power adapter and plug the other end into a wall power outlet.
2. Remove the white protective needle cover by gently pulling towards the fr of the uniont t.
3. Turn the power & volume control knob clockwise to turn on the record player.
4. Place a vinyl record on the turntable platter and select the desired speed (33/45/78RPM) according to
the record. when playing a 45RPM record, use the included 45RPM adapter. NOTE:
5. Open the tone arm clip to release the tone arm. Push the lift lever(it sits beside the auto stop switch)
backwards to raise the tone arm and gently move the tone arm to the desired position over the record.
The turntable will begin to spin when the tonearm is moved toward the record(when the AUTO STOP
switch is ON). Push the lift lever forwards to lower the tone arm slowly onto the desired position on the record to start
playback .
6. Turn the volume control knob to adjust the volume.
NOTE: If the AUTO STOP ON/OFF Switch is turned ON, the record will stop automatically when nished. If Auto Stop Control is
turned OFF, record will NOT stop automatically when nished. The AUTO STOP function applies to most 33RPM vinyl records.
However, for some records, it will stop when it does not come to the end, or it will not stop when it comes to the end when
AUTO STOP is ON.
RCA OUTP MODE UT
Connect your own speaker system to the RCA port of the record player with an -3.5mm audio cable (not included). RCA
NOTE: the RCA cables are color coded. The red plug cable must be plugged into the red jack on both the record player and
external amplier or speaker system. The wh e plug cable must be plugged into the white jack on both the record player and it
external amplier or speaker system.


Product specificaties

Merk: Fenton
Categorie: Platenspeler
Model: RP161LW

Heb je hulp nodig?

Als je hulp nodig hebt met Fenton RP161LW stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Platenspeler Fenton

Handleiding Platenspeler

Nieuwste handleidingen voor Platenspeler