Pagina 1/4
TLP 350MV ā€¢ Setup Guide
Overview
The ExtronĀ® TLP 350MV is a wall-mounted TouchLinkā„¢ Panel that
provides simple and versatile conļ¬guration and control for a range
of IP LinkĀ® control systems.
Graphic and text objects are displayed on the screen. These objects
have system control functions associated with them and the
Touchpanel allows you to control those functions.
Two BNC connectors allow the screen to be used to preview composite video or S-video.
NOTE: The RJ-45 output on the rear panel of the TLP 350MV must be connected to a network switch, hub, or router that
is connected to an Ethernet LAN or the Internet. An Extron IP Link controller must also be connected to the same
network. Suggested models include IPL T S series (for example, IPL T S4), IPL 250, IPL T CR48, or IPL T SFI244 .
This guide provides basic instructions for experienced installers to mount and perform initial conļ¬guration on the
TLP 350MV. Full instructions and reference material can be found in the , which is available on the TLP 350MV User Guide
Extron Web site (www.extron.com).
TLP 350MV Front Panel Features
Figure 1. TLP 350MV Front Panel (left) and Front Panel with Bezel Removed to Show Recessed Buttons (right).
a monitors the level of ambient light and adjusts the screen brightness and button backlighting.Light sensor ā€”
b provides a graphical user interface with a pressable touch screen display.3.5 inch LCD screen ā€”
c provides audible feedback.Speaker ā€”
d detects movement in front of the panel. When no motion has been detected for a user-deļ¬ned Motion detector ā€”
period of time, the unit goes into sleep mode, which shuts down the screen display and inactivates all the buttons.
When motion is detected, these functions are restored.
e can be conļ¬gured to perform user-deļ¬ned functions, using the Extron Global Eight backlit push-buttons ā€”
Conļ¬gurator software.
f intended for volume control but it can be conļ¬gured for other functions.Encoder knob ā€”
Two buttons and an LED are recessed behind the bezel. Remove the bezel using the
Extron removal tool inserted into the tabs on the bottom of the panel, as shown in the
ļ¬gure at right.
g activates the on screen menus for calibrating and setting the unit.Menu button ā€”
h allows the unit to be reset in any of four different modes. See the Reset button ā€”
"Reset Modes" section on the back page of this setup guide.
i is visible only when the faceplate has been removed. It lights as an Reset LED ā€”
indicator for the reset modes.
14
5
6
2
3
7
8
9
ExtronExtron
Remove Bezel
at Tabs
Extron Removal Tool
TLP 350MV ā€¢ Setup Guide (Continued)
Mounting the TLP 350MV
Decide where to mount the TLP 350MV and whether to use a 3-gang mud ring or a 3-gang UL-certiļ¬ed junction box. The
mounting instructions are slightly different depending on your choice:
Using a Mud Ring
1. Use the template provided with the mud ring to mark
the wall. For the mud ring provided, the hole must be
5 25/32 inches (14.68 cm) wide x 3 7/8 inches (9.83 cm) high.
2. Cut a hole in the wall. To avoid making the hole too big, cut
inside the lines you marked.
3. Test the ļ¬t by inserting the mud ring into the hole in the wall.
If necessary, use a rasp or ļ¬le to enlarge the hole.
4. Insert the mud ring into the hole and use a screw driver to
turn and tighten the locking arms until they clamp the mud
ring to the mounting surface. Do not overtighten.
5. Secure the wall adapter (provided) to the junction box, using
the four screws (provided).
6. Use the Extron removal tool provided to separate the bezel
from the TLP 350MV (see ļ¬gure on previous page).
7. Extron recommends using the provided Power over Ethernet (PoE) power
supply. Connect a network switch to the "LAN In" port and run a second cable
from the "Pwr LAN Out" port to the Touch Panel mounting site (see the ļ¬gure below).
CAUTION: Whether you use a PoE power supply or a 12 VDC power supply (not provided), you must read the
caution in the Power Supply section of the .TLP 350MV User Guide
NOTE: If both a PoE power supply and a 12 VDC power supply are present, the unit will draw power from the PoE
power supply only.
8. Run video cables with to the mounting site. Leave enough slack in the cables to connect them to the TLP 350MV. Pull
the cables through the mud ring. Connect the cables as shown in the diagram below.
9. Plug the cables into the rear panel connectors of the TLP 350MV (refer the ).TLP 350MV User Guide
10. Secure the TLP 350MV to the mud ring using the two screws provided (top center and bottom center).
11. Do not replace the bezel at this time. You will need access to the recessed Menu and Reset buttons to conļ¬gure the
unit.
PWR LAN-OUT LAN-IN
To Network SwitchTo TLP 350MV
Power over Ethernet (PoE) Power Supply
C (yellow cable) Video/Y (white cable)
Locking Arms (4)
Screws (2)
Clips (4)
Mud Ring
TLP 350MV
Bezel
PC
LAPT O P
DVD
DOC CAM
AUXIL IARY
DIS PLAY ON
DIS PLAY OF F
MUT E
4
9
Using a UL-Certiļ¬ed Junction Box
1. Locate a wall stud and mark the position where the junction
box will be placed. Use the size speciļ¬cations provided by the
manufacturer.
2. Cut a hole in the wall. To avoid making the hole too big, cut
inside the lines you marked in step .1
3. Test the ļ¬t by inserting the junction box into the hole in the
wall. If necessary, use a rasp or ļ¬le to enlarge the hole.
4. Insert the junction box into the hole in the wall. Secure it to the
stud using two screws or nails, as appropriate. The front edge of
the junction box must be ļ¬‚ush with the front surface of the wall.
5. Secure the wall adapter (provided) to the junction box, using the
four screws (provided).
6. Connect a network switch to the "LAN In" port of the PoE
power supply (provided). Run a second cable from the "Pwr LAN
Out" port to the TLP 350MV mounting site (see the ļ¬gure on the
previous page).
7. Run video cables to the mounting site. Leave enough slack in the cables
to connect them to the TLP 350MV. Pull the cables through the mud ring.
8. Connect the cables as shown in the diagram at the bottom of the previous page.
9. Secure the TLP 350MV to the wall adapter. Two clips at the top and two at the bottom
audibly click when the panel moves into place. You should also use the two screws provided (top center and bottom
center).
10. Do not replace the bezel at this time. You will need access to recessed the Menu and Reset buttons to conļ¬gure the
unit.
Conļ¬guring the TLP 350MV (Initial Setup)
Before use, the TLP 350MV must be conļ¬gured using the on-screen menus. There are ļ¬ve different screens (Main, Vol, Time,
IP, and Vid) that can be selected by pressing the appropriate button at the edge of the screen. There is also an Main Exit
button at the bottom left corner of the screen for leaving the menus.
NOTE: Only the screen provides links to the Main Vol Time IP Vid, , , and screens. All other screens have a link to return to
the screen. After calibrating each group of settings, return to the screen to access the next screen.Main Main
Setup Menu
1. Press the recessed Menu button on the front panel to activate the
top-level menu screen. The menu opens at the Main Setup Page.
2. Touch an area of the screen to bring it into focus and use the and Up
Down buttons or the volume control knob to adjust the value. Some
options have a single button and toggle between and when Off On
the button is pressed.
Use the different menu pages to adjust the following options. For more
details, see the user guide.
Main (shown at right) Shows Power over Ethernet status and adjusts ā€”
the Sleep timer, Backlight, Auto Backlight, and LED Backlight functions.
Vol ā€” Adjusts the Master, Click (global button sounds), and Sounds
(playback .wav ļ¬les) volume settings.
Time ā€” Sets the correct time and date.
IP ā€” Sets the IP address and the subnet mask, and enables or disables Dynamic Host Conļ¬guration Protocol.
Vid ā€” Provides a small video preview window and the controls to calibrate video contrast, color, brightness, and tint.
Main
Vol
Time
IP Exit
Dn Up
Dn
OnOn
Up
On
Sleep: 00000 Sec
Backlight: 075%
Auto
Vid
LED Motion
Backlight
PoE
Active
Wall Stud
Junction Box
Wall Adapter
TLP 350MV
Bezel
PC
LAPT O P
DVD
DO C CAM
AUXI LIARY
DIS PLAY O N
DIS PLAY O FF
MUT E
5
9
4
Scre
ws (2)


Product specificaties

Merk: Extron
Categorie: Afstandsbediening
Model: TLP 350MV
Kleur van het product: Black, White
Ingebouwd display: Ja
Gewicht: 400 g
Breedte: 163 mm
Diepte: 44 mm
Hoogte: 114 mm
Beeldscherm: TFT
Beeldschermdiagonaal: 3.5 "
Resolutie: 320 x 240 Pixels
RAM-capaciteit: 16 MB
Certificering: CE, c-UL, UL\nCE, C-tick, FCC Class A, ICES, VCCI
Interface: Bedraad
Duurzaamheidscertificaten: RoHS
Temperatuur bij opslag: -25 - 70 Ā°C
Maximumbereik: - m
Luchtvochtigheid bij opslag: 10 - 90 procent
Flash memory: 7 MB
Bedrijfstemperatuur, bereik: 32 - 122 Ā°F
Input type: Aanraakscherm
juiste gebruik afstandsbediening: TV set-top box, DVD/Blu-ray, PC, TV, VCR
Bedrijfstemperatuur (T-T): 0 - 50 Ā°C
Relatieve vochtigheid in bedrijf (V-V): 10 - 90 procent
Display met achtergrondverlichting: Ja
Temperatuurbereik voor opslag (T-T): -13 - 158 Ā°F

Heb je hulp nodig?

Als je hulp nodig hebt met Extron TLP 350MV stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Afstandsbediening Extron

Handleiding Afstandsbediening

Nieuwste handleidingen voor Afstandsbediening

Zalman

Zalman ZM-VE350 Handleiding

11 September 2024
Canon

Canon BG-R20 Handleiding

11 September 2024
Canon

Canon BG-R20EP Handleiding

11 September 2024
Mosconi

Mosconi DSP6T8 Handleiding

4 September 2024
Mosconi

Mosconi RC MINI Handleiding

4 September 2024
Ridem

Ridem CRC UNB Handleiding

29 Augustus 2024
Ridem

Ridem CRC UNW Handleiding

28 Augustus 2024
ORNO

ORNO OR-GB-458 Handleiding

22 Augustus 2024
ORNO

ORNO OR-GB-447 Handleiding

22 Augustus 2024
ORNO

ORNO OR-GB-448 Handleiding

22 Augustus 2024