Extron PS 125 Handleiding


Lees hieronder de 📖 handleiding in het Nederlandse voor Extron PS 125 (6 pagina's) in de categorie Niet gecategoriseerd. Deze handleiding was nuttig voor 7 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/6
1
PS 125 ‱ Installation Guide
Introduction
The Extron PS 125 is a high performance, 60W, 12 VDC power supply. The auto‑switchable
100 VAC to 240 VAC input can supply a maximum current of 5 amps for up to eight outputs.
Each DC output is on a two‑pole captive screw connector, with no per‑output current limitation. Two‑tone LEDs on the front and
rear panels indicate normal operation (green) and overload condition(red).
The rack mountable PS 125 has a 1U high, quarter rack wide, 8.5 inches deep metal enclosure, allowing the PS 125 to take
advantage of a variety of mounting options (see (see page3).
Mounting the PS 125
FCC Class B Notice
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part15 of the
FCC rules. These limits provide reasonable protection against harmful interference in a residential installation. This equipment
generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may
cause harmful interference to radio communications. There is no guarantee that interference will not occur. If this equipment
does cause interference to radio or television reception, which can be determined by turning the equipment off and on, you are
encouraged to try to correct the interference by one or more of the following measures:
‱ Reorient or relocate the receiving antenna.
‱ Increase the separation between the equipment and receiver.
‱ Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
‱ Consult the dealer or an experienced radio/TV technician for help.
In order to maintain compliance with FCC regulations, shielded cables must be used with this equipment. Operation with non‑
approved equipment or unshielded cables is likely to result in interference to radio and TV reception. The user is cautioned that
changes and modications made to the equipment without the approval of the manufacturer could void the user’s authority to
operate this equipment.
NOTE: This unit was tested with shielded I/O cables on the peripheral devices. Shielded cables must be used to ensure
compliance with FCC emissions limits.
For information on safety guidelines, regulatory compliances, EMI/EMF compatibility, accessibility, and related topics, see the
Extron Safety and Regulatory Compliance Guide on the Extron website.
Front and Rear Panel Features
All power and output connections are on the rear panel.
1
Power Status LEDs
2
Overload LED
3
IEC Connector/Power Supply
4 DC Output Connectors
Figure 1. PS 125 Front and Rear Panels
PS 125
12 VDC 5A POWER SUPPLY
OVERLOAD
OUTPUTS
50-60 Hz
100-240V~
1.3A MAX
12 VDC TOTAL OUTPUT 5A
1 2 3 4 6 8
5 7
11
4411
22
33
2
LED indicators
1 — (see on the previous page) These front and rear panel LEDs indicate the PS 125 Power Status LEDs figure1
status by lighting Green when power is applied and current draw is normal.
2 Overload LED — lights Red to indicate a current overload condition or when an output is shorted.
ATTENTION:
‱ Continued operation in an overload condition may cause premature power supply failure.
‱ Un fonctionnement ininterrompu en situation de surcharge peut entraĂźner la dĂ©faillance prĂ©maturĂ©e de la source
d’alimentation.
NOTE: To identify the shorted output, unplug the outputs one at a time until the Overload LED lights off.
Input Power
Apply power to the PS 125 using the
supplied IEC power cord.
3 — IEC Connector/Power Supply
Plug one end of an IEC cord into this
connector and the other end into a
100‑240 VAC source.
DC Outputs
4 DC Output Connectors —
Connect the power cables from
devices that will receive power from
the PS 125 to these 3.5 mm captive
screw connectors.
The PS 125 supports up to eight
power supply outputs. For details
on limitations and how to wire these
captive screw connectors, see
Output Power — Wiring the DC
Output Connectors on page3.
Connections
Input Power — Using the IEC
Power Cord
Use the included IEC power
cord to connect the PS 125 to a
100 VAC to 240 VAC, 50‑60 Hz power
source.
Figure 2. PS 125 Application Diagram
ATTENTION:
‱ For permanently connected equipment, there must be a readily accessible disconnect device incorporated in the
building installation wiring.
‱ Pour les Ă©quipements branchĂ©s en permanence, un dispositif d’isolement rapidement accessible doit ĂȘtre intĂ©grĂ© Ă 
l’installation Ă©lectrique du bĂątiment.
‱ The circuit breaker used for this connection should be rated 20 amps maximum.
‱ Le disjoncteur utilisĂ© pour cette connexion doit avoir une tension nominale de 20 A max.
POWER
12V
--A MAX
POWER
12V
--A MAX
OUT PUTS
OVERLOAD
123468
57
12 VDC T OTAL OUT PUT
5A
50-60 Hz
100-240V~
5A MAX
Extron
PS 125
12VDC 5A
Power Supply
Extron
Product
Extron
Product
Output 2
Output 3
Output 4
Output 6
Output 8
Output 5
Output 7
Output 1
3
PS 125 ‱ Installation Guide (Continued)
Output Power — Wiring the DC Output Connectors
The PS 125 can supply 12 VDC to multiple devices using 3.5mm, 2‑pole captive screw connectors. The combined current draw
of the connected devices must not exceed 4 amps.
ATTENTION:
‱ To verify proper polarity before connection to a device, plug in the power supply with no load and check the output
polarity with a voltmeter. Remove power before wiring.
‱ Pour vĂ©rifier la polaritĂ© avant la connexion, brancher l’alimentation hors charge et mesurer sa sortie avec un voltmĂštre.
Couper l’alimentation avant de faire l’installation Ă©lectrique.
‱ Ensure that you observe correct wire polarity. The two power cord wires must be kept separate while the power supply
is plugged in.
‱ Assurez‑vous de respecter la polaritĂ© correcte du cĂąble. Les deux cordons d’alimentation doivent ĂȘtre maintenus Ă 
l’écart tant que la source d’alimentation est branchĂ©e.
To connect products to the outputs of the PS 125:
1. Cut the DC output cord to the length required.
2. Strip the jacket of the conductor wire (see figure 3 on the right).
ATTENTION:
‱ The length of the exposed wires in the stripping process is . The ideal length critical
is 3/16 inches (5 mm). Any longer and the exposed wires may touch, causing a short
circuit. Any shorter and the wires can be easily pulled out even if tightly fastened by the
captive screws.
‱ La longueur des cĂąbles exposĂ©s est lorsque l’on entreprend de les primordiale
dĂ©nuder. La longueur idĂ©ale est de 5mm (3/16inches). S’ils sont trop longs, les cĂąbles
exposĂ©s pourraient se toucher et provoquer un court‑circuit. S’ils sont trop courts, ils
peuvent ĂȘtre tirĂ©s facilement, mĂȘme s’ils sont correctement serrĂ©s par les borniers Ă  vis.
‱ Do not tin the stripped power supply leads before installing the captive screw
connector. Tinned wires are not as secure in the captive screw terminals and could pull
out.
‱ Les cĂąbles Ă©tamĂ©s ne sont pas aussi bien fixĂ©s dans les borniers Ă  vis et pourraient
s’arracher. Ne pas Ă©tamer le cĂąble d’alimentation dĂ©nudĂ© avant d’avoir installĂ© le
bornier Ă  vis.
Figure 3. DC Output
Wiring
3. Slide the leads into the supplied 2‑pole captive screw plug and secure them using an Extron Tweeker or small screwdriver.
4. Use the supplied tie wrap to strap the power cord to the extended tail of the connector.
Mounting the PS 125
There are several optional accessories for mounting the PS 125 (see the mounting options at www.extron.com).
UL Rack Mounting Guidelines
The following Underwriters Laboratories (UL) guidelines pertain to the installation of the PS 125 into a rack.
‱ Elevated operating ambient temperature — If installed in a closed or multi‑unit rack assembly, the operating ambient
temperature of the rack environment may be greater than room ambient. Therefore, consider installing the equipment in an
environment compatible with the maximum ambient temperature specied by Extron (Tma = +32 to +122 °F [0 to +50 °C]).
‱ Reduced air flow — Installation of the equipment in a rack should be such that the amount of air ow required for safe
operation of the equipment is not compromised.
‱ Mechanical loading — Mounting of the equipment in the rack should be such that a hazardous condition is not achieved
due to uneven mechanical loading.
‱ Circuit overloading — Consideration should be given to the connection of the equipment to the supply circuit and the
effect that overloading of the circuits might have on overcurrent protection and supply wiring. Appropriate consideration of
equipment nameplate ratings should be used when addressing this concern.
‱ Reliable earthing (grounding) — Reliable earthing of rack‑mounted equipment should be maintained. Particular attention
should be given to supply connections other than direct connections to the branch circuit (such as the use of power strips).
Power Supply
Output Cord
+–
Ridges
Smooth
2-Pole Orange
Captive Screw
Connec rto
(12V)
Tie apWr
3/16”
(5 mm) Max.


Product specificaties