Extron DTP T FB 232 Handleiding


Lees hieronder de 📖 handleiding in het Nederlandse voor Extron DTP T FB 232 (4 pagina's) in de categorie Niet gecategoriseerd. Deze handleiding was nuttig voor 5 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/4
1
DTP T FB 332 and DTP T FB 232 • Setup Guide
This guide provides instructions for an experienced installer to install either
the Extron DTP T FB 332 or the DTP T FB 232 switching transmitter into an
Ackermann GB3 (OBO Betterman), MK Electric CableLink Plus Modular,
MK Electric CableLink Plus
Single Pan, ElectraPlan, or PUK
oor box and to make all
connections.
The transmitters switch
between one analog video and
one digital (HDMI) video input
and, paired with a compatible
receiver, can extend the
selected signal up to
330 feet (100 m) (DTP T FB 332) or
230 feet (70 m) (DTP T FB 232).
Installation
Planning
CAUTION: Failure to check these items may result in personal injury or property damage.
ATTENTION : La non-vérication des éléments listés ci-dessous peut provoquer des blessures ou dommages matériels.
Check that the installation meets the building, electrical, and safety codes.
Mounting and Cabling
Typica bol Floor x
1
2
3
Step 1 Preparing the floor box
a. Install the oor box as directed by the manufacturer.
NOTE: Run all required cables and secure them with cable clamps.
b. Turn off or disconnect all equipment power sources.
Step 2 Installing adapters
a. Determine a position in the oor box to mount the DTP T FB unit (see the image at right).
b. Identify the applicable adapter plates for the oor box (see the table below).
c. Install adapter plates to the same pair of mounting slots (see the table below for slot
recommendations) for the same position in the oor box. Slide the top ange into the
mounting slot and rotate the adapter plate down so the bottom ange rests against the
wall of the oor box.
Floor Box Adapter Plates Positions Highest
Mounting Slot
Additional Notes
Ackermann GB3
(OBO Betterman)
995241 (2)
995241 (2) and 995242 (1)
1 and 3
2
3rd from top For position 2, use the provided screws to attach
the 995242 adapter plate to either 995241
adapter plate.
MK Electric CableLink Plus
Single Pan
995243 (2) 1 and 3 N/ADo not use position 2. Use mounting screws to
secure the adapter plates to the oor box (see
figure 3 on page 3).
MK Electric CableLink Plus Modular 995244 (2) 1, 2, and 3 3rd from top
ElectraPlan 995300 (2) 1, 2, and 3 3rd from top
PUK 995300 (2) 1, 2, and 3 3rd from top
IMPORTANT:
Go to www.extron.com for the complete
user guide, installation instructions, and
specications bef
ore connecting the
pr
oduct to the po
wer source.
CONFIG G
RS-232 IR
Rx TxTx Rx
HDMI IN VGA IN
DTP T FB 332
AUDIO IN
OVER DTP
RESET
HDMI
VGA
HDCP
AUTO
Top Panel
Figure 1. DTP T FB Unit features
Side (under adapter plate)
(Before installation in floor box)
Side (above adapter plate)
(After installation in floor box)
Top
A DC power input
B Remote RS-232
C TP function switch
D DTP output
E HDMI input
F VGA Input
G Audio input
H RS-232/IR Over TP output
I Conguration (USB)
J Reset button
K LEDs
SIG LINK
OUT
G
REMOTE
RS-232
Rx Tx
POWER
12V
1.0A MAX
− +
DTP
HDBT
Side Panel
2
DTP T FB 332 and DTP T FB 232 • Setup Guide (Continued)
Step 3 — Make side panel connections under the adapter plates and set the
TP function switch
A (see on page 1) — Connect the included 12 VDC power supply to either unit, Power figure 1
transmitter or receiver, as shown at right. Use the included tie-wrap to strap the cord to the
captive screw connector.
Connect an IEC power cord between the power supply and a 100-240 VAC, 50-60 Hz source.
NOTE: If the TP switch (C) is in , one power supply can power both units. DTP
If the switch is in , each unit requires its own power supply.HDBT
B — For serial RS-232 control, connect a host device or control system to Remote RS-232 port
the 3.5 mm, 3-pole captive screw connector. The wiring and protocol are shown at right.
C TP function switch
If the receiving device is in the Extron DTP series, set this switch to . The TP output DTP
consists of HDMI with embedded audio, analog audio, RS-232 and IR, and remote power. The
transmitter and receiver can be powered by one 12 VDC power supply connected to either unit.
For an HDBaseT-enabled receiver type, set this switch to position. The TP output consists of HDMI with embedded audio plus HDBT
RS-232 and IR. The transmitter and receiver each requires its own 12 VDC power supply.
ATTENTION:
Position this switch connecting the appropriate device to the TP connector. Failure to comply can damage the BEFORE
endpoint.
Positionnez le sélecteur de connecter l’appareil approprié au connecteur TP. Ne pas respecter cette procédure AVANT
pourrait endommager le point de connexion.
D — Connect the Out (RJ-45) port to the DTP In port on the receiver. Extron recommends that you terminate both cable ends in Out port
accordance with the following, at a minimum: TIA/EIA T 568B and 24 AWG, solid conductor, shielded cable with 400 MHz bandwidth.
ATTENTION:
Do not connect this connector to a computer data or telecommunications network.
Ne connectez pas ces port à des données informatiques ou à un réseau de télécommunications.
Signal LED indicator — Lights when the device is transmitting a video signal or a test pattern.
Link LED indicator — Lights when a valid link between a DTP or HDBT input and output is established.
Step 4 — Mount the unit in the floor box
a. Place the DTP T FB unit in the desired position in the oor box so that the side panel connectors face
towards the opening of the oor box.
ATTENTION:
Ensure there is enough space between the top panel connectors and the lid of the oor box so the lid fully closes.
Assurez vous qu’il y ait assez d’espace entre les connecteurs du panneau supérieur et le couvercle du boîtier de sol an
que celui-ci puisse se fermer entièrement.
b. Using the provided self-threading screws, secure the DTP T FB unit to the adapter plates (see gures 2 through 5).
Ackermann GB3 (OBO Betterman) floor box
DTP T F B 332
POWE R
DTP T F B 332
NOTE: For position 2, install
adapter plate 995242 to
one of the other adapter
plates.
995242 995241
Figure 2. DTP T FB Unit in an Ackermann GB3 (OBO Betterman) Floor Box
Power Supply
Output Cord
Ridges
Smooth
Captive
Screw
Connector
3"
16 (5 mm) MAX
SECTION A–A
AA
RxTx Gnd
RS-232 De
vice 9600 Baud
8 data bits
No parity 1 stop bit
G
REMOTE
RS-232
Rx Tx
3"
16 (5 mm) MAX
5
Pin
1
2
3
6
7
8
4
Wire color
White-green
Green
White-orange
White-blue
Orange
White-brown
Brown
Blue
TIA/EIA T
568B
TP Wires
1 8234567
Pins:
3
MK Electric CableLink Plus Single Pan floor box
DTP T FB 332
W
DTP T FB 332
995243
995243
Figure 3. DTP T FB Unit in an MK Electric CableLink Plus Single Pan Floor Box
MK Electric CableLink Plus Modular floor box
DTP T FB 332
DTP T FB 332
995244 995244
Figure 4. DTP T FB Unit in an MK Electric CableLink Plus Modular Floor Box
ElectraPlan or PUK floor box
DTP T FB 332
XTP T FB 202
995300
995300
Figure 5. DTP T FB Unit in an ElectraPlan (or PUK) Floor Box
Step 5 — Make side panel connections above the adapter plates
E (see on page 1) — Connect an HDMI cable between this port and the HDMI output port of the digital videoHDMI input port figure 1
source.
NOTE: See the LockIt® Lacing Brackets on page 4 of this guide to securely fasten the HDMI connector to the transmitter.
F — Connect a VGA cable between this port and the VGA output port of the analog video source.VGA Input 1 port